§ 13.05.060 — Water meter installations
Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 13.05.060
Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/91532215-256f-4222-b186-89cbb7541645
13.05.060 - Water meter installations.
A. General. 1. All water meters, two inches and smaller, except sub-meters, are to be installed by the city. Licensed plumbers shall install all other piping (and meters larger than two inches necessary for the installation in accordance with this title and the City Plumbing Code. All water meters (except sub-meters) shall be purchased from the city. 2. The customer shall provide a suitable location in the building which is acceptable to the city where the city water meter is easily accessible and convenient for the installation, reading, operation, protection, and maintenance of the meters and equipment in accordance with requirements of the city, which, in all instances must protect the water meters from freezing. 3. Meter pits shall be required for manufactured homes, mobile homes, and other special circumstances approved by the city, and shall be located generally within the front lot utility easement behind the shut-off valve. The customer shall own and maintain meter pits. 4. Meter installations in outside vaults must have prior written authorization from the city. Evidence must be provided showing that it is not practical to place the meter inside a building. Plans shall be submitted to the city for all outside meter vaults. 5. The city is responsible for the operation and maintenance of the meter and remote reading device for residential services. All other valves, piping, meter pits, vaults, backflow preventers, pressure reducing valves, etc. are the responsibility of the customer to own, operate, and maintain. 6. All building fire protection systems one and one-half-inch or less in size shall be installed after the City meter serving the building. The fire protection system shall be provided with a backflow preventer. Building fire protection systems for single family dwellings which are integral to the building plumbing system as allowed by City Building Code do not require a backflow preventer. Building fire protection systems two-inch or larger in size shall have a separate service line from the main. No meter will be needed; but, a backflow preventer will be required for fire protection systems two-inch and larger. B. Sizing. Water meters shall be sized in accordance to the following table: Size | Maximum Peak Flow Allowable - Gallons Per Minute (GPM) ¾ inch | 15 GPM 1 inch | 25 GPM 1½ inches | 50 GPM 2 inches | 100 GPM 3 inches | 200 GPM 4 inches | 450 GPM 6 inches | 950 GPM 8 inches | 1,550 GPM 10 inches | 2,450 GPM C. Meters Up to Two Inches (See Figure 1 at the end of this chapter). 1. The water service line installed from the water main to the meter shall be brought up through the floor in a vertical position. An approved valve must be installed where the service line enters the building, about twelve inches above the floor. An approved valve shall also be installed on the outgoing side of the meter immediately adjacent to the meter. 2. The meter shall be located so that the bottom of the meter is from six inches to eighteen inches above the finished floor line and shall be installed in the horizontal position. The meter shall be set in a laundry area, furnace room, or other area not normally considered as living area. The meter shall not be installed in crawl spaces or other areas of inconvenient access. 3. Meters up to and including one inch may be supported by the piping. All others must be supported by a suitable mounting bracket, blocking, or metal stand. 4. Meters shall be installed within four feet of a floor drain, when available, unless an alternate location is approved by the city. 5. Clearances for accessibility to the meter must be provided. Normally an area two feet by two feet is required with a clearance of at least twelve inches on both sides of the meter. Adequate access, as determined by the city, to the meter location is also required. 6. Meters must be installed inside the building in a heated area. 7. Any connection to the service before the meter or any by-pass around the meter is prohibited. Unless specifically allowed by the city, by-passes around the meter will not be allowed. Any customer who is found with an illegal by-pass around the meter shall immediately have his water service turned off until the by-pass is removed. 8. Valves before and after the meter shall be gate, globe, angle, or ball valves made of brass, copper, or other city approved materials up through two inches in size. 9. Automatic meter reading equipment will be installed near the meter inside the residence, or at a suitable location outside the building. 10. Meter Pits. Frost-proof meter pits may be allowed for two-inch and smaller meters. Frost-proof meter pits must be used for all manufactured homes or mobile homes. The meter pit shall generally be installed within the front lot utility easement behind the water service line shut-off valve. Meter pits, including lids, located in sidewalks or paved areas must be specifically designed to accommodate AASHTO H-20 traffic loading. The customer shall own and maintain the meter pit. Meter pits and setters shall be pre-fabricated and must be designed for cold weather conditions. The meter pit riser and valves must be located at least two inches from the pit wall. For meter pits one-inch and smaller, the water meter must be no more than fourteen inches from the top lid of the meter pit cover. For one and one-half-inch and two-inch meter pits, the water meter must be no more than twenty inches from the top lid. Minimum inside diameter of the pit shall be twenty inches for three-quarter-inch and one-inch meters and thirty-six inches for one and one-half-inch and two-inch meters. Lid diameters shall be no less than eleven inches for meter pits one-inch and smaller and shall be no less than eighteen inches for meter pits one and one-half-inch and larger. Automatic meter reading equipment, suitable for meter pits, will be installed. (See standard meter pit detail — Figure 3 at the end of this Chapter.) D. Meter Setups Three Inches and Larger (See Figure 3 at the end of this chapter). 1. The same general requirements apply for installation as for smaller meters. Meters should be installed in a mechanical room of the building, near a floor drain, if available, and in a horizontal position. Valves must be installed on both sides of the meter. 2. All meters larger than two inches must have at least thirty-six inches clearance above the meter, eighteen inches below the meter, and eighteen inches clearance on the sides. The piping must include couplings or other arrangement to provide for easy removal of meters. 3. A minimum straight distance of ten pipe diameters is required upstream of each meter setup larger than two inches, unless an approved strainer is used. 4. All meter setups, three inches and larger, shall have a two-inch test plug on the discharge side to allow for meter testing. This test plug shall be placed before the valve on the customer side. 5. A compound meter, a single-jet meter, or a parallel turbine-displacement meter setup (if a bypass is absolutely needed by the customer) may be used for three-inch and larger services. Magnetic flow meters may be used for services six inches and larger. 6. Turbine meters alone may be used for irrigation-only services if approved by the city. 7. Check valves used in the parallel turbine-displacement meter setup shall be internal spring loaded check valves. They shall have a cast iron body, stainless steel five-pound springs, stainless steel hinge pins and stops, Teflon spring and hinge bearings, and Buna-N or equal seals. 8. Three-inch valves may be gate, globe, angle or ball valves made of brass, and copper or other approved material. Gate valves meeting AWWA C500 or C509 or butterfly valves meeting AWWA C504 are also acceptable for three-inch valves. 9. All valves four-inch and larger shall be gate valves meeting AWWA C500 or C509 or butterfly valves meeting C504. 10. All meters, valves, and piping must be supported by suitable blocking or metal stands. E. Meter Vaults (See Figure 4 at the end of this chapter). The same general installation requirements for meter setups (subsections C and D of this section) apply to meter vault installations. Vaults must meet the following requirements: 1. Vaults must be constructed of reinforced concrete with a minimum depth of seven feet floor to ceiling. The minimum length and width shall be four feet. The floor must be concrete and the entire vault must be watertight and insulated as necessary. A floor drain to daylight or a dry sump is necessary. 2. Separate water services (and meters) for irrigation only purposes are not permitted in outside vaults, except for public parks, townhouse developments and other special circumstances, specifically approved by the city. 3. The meter setup must have eighteen-inch clearance to the floor and eighteen-inch clearance on all sides. 4. The piping must include couplings or other arrangements to provide for easy removal of the meter. 5. Valves must be provided on both sides of the meter, inside the vault, and with sufficient clearance for operation and maintenance. 6. All meters, valves, and piping must be supported by suitable blocking or metal stands. 7. A suitable locking hatch will be provided in one corner of the vault for access. The hatch must be provided with hold up arms. Manhole castings are not acceptable. Minimum size shall be a twenty-four-inch opening. Aluminum steps or ladder shall be provided. F. Submetering. Sub-meters are meters downstream of the city water meter installed for the purpose of proportioning municipal water/wastewater charges between various tenants or residents. 1. Customers desiring one or more sub-meters for various tenants or residents shall furnish, install, maintain, read, and bill on such meters at their own expense.
(Ord. 45-06 (part), 2006) (Ord. No. 28-14, §§ 1, 2, 11-18-2014)
Ask a question about Casper law
Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.