13.05.080 - Pressure reducing valves.
A. Pressure reducing valves will be required for new residential and commercial buildings inside the city of Casper where the static pressure is greater than sixty-five pounds per square inch. Their purpose is to save water and reduce wastewater flow. B. The valve shall be located on the discharge side of the water meter after the shut-off valve and a minimum of four pipe diameters from the shut-off valve. All inside house fixtures must be served by the pressure-reducing valve. Outside hose bibs and outside landscape irrigation connections may be left at full main pressure if desired. C. The pressure-reducing valve, if required in conjunction with a backflow prevention device, shall be installed downstream of the backflow prevention device. D. The pressure-reducing valve shall be set to limit inside house pressure to a maximum of sixty-five pounds per square inch. E. Pressure-reducing valves must be approved by the city building inspection division.
(Ord. 45-06 (part), 2006)