15.24.170 - Section 427 added—Accessible working space.

Section 427—Each appliance typically found in the mechanical room of a single family or multi-family residential structure shall have the minimum space available to allow for the adequate installation and repair of the appliance. There shall be adequate space to allow the appliance to be replaced or serviced with minimal or no disruption to the other appliances in the room. These space requirements are minimums and may vary with the specific equipment involved. The Code Official may approve different spacing with prior approval. APPLIANCES | MINIMUM SPACE PER APPLIANCE Water heater | 4 square feet floor space Water softener | 8 square feet Furnace | 24 square feet Hot water boiler | 24 square feet Central vacuum | 9 square feet Water meter | (CPU specifications Section 39-4) 6" from floor to bottom of the meter. 9 square feet floor space total

(Ord. No. 17-24, 8-20-2024)