15.28.190 - Ampere service requirements—New buildings and utility poles.

A. Requirements. All services installed within or on all new buildings, structures or utility poles, and all alterations in and additions to wiring in or on buildings now existing, shall be a minimum of one hundred twenty-five amperes when the computed load is not more than one hundred amperes. Where the computed minimum load exceeds one hundred amperes, the service size shall be increased by one hundred twenty-five percent. Wafer and tandem circuit breakers are not allowed on new construction. Basements shall be included when computing the square foot area of a building for the size of service required. B. Exceptions. 1. Individual service, when approved by the city electrical inspector due to limitations of supply source or load requirements, shall not be smaller than three No. 6 A.W.G. conductors, when serving no more than three circuits. 2. For installations to supply limited loads of a single branch circuit, when approved by the city electrical inspector, the conductors shall not be smaller than the conductors of the branch circuit, and shall be a minimum of three No. 6 A.W.G. conductors. 3. Billboards with not more than a thirty-ampere computed load may be served by three No. 6 A.W.G. conductors. 4. For other installations and for temporary services on construction poles serving not more than two twenty-ampere, one-hundred-twenty-volt, circuits may be served by three No. 6 A.W.G. conductors. All one-hundred-twenty-volt, single-phase, fifteen-ampere and twenty-ampere receptacle outlets on construction sites shall have ground fault circuit interrupters. Two-hundred-thirty-volt outlets shall only be used for two-hundred-thirty-volt utilization equipment. C. Protection of Ungrounded Conductors. 1. Protection of ungrounded conductors shall be provided by an overcurrent device in series with each ungrounded service conductor having a rating or setting not higher than the allowable ampacity of the conductor. 2. Where more than one and not more than six overcurrent devices provide the required protection for the ungrounded conductors, their total ampacity shall not exceed the allowable ampacity of the ungrounded conductor(s). Refer to Section 240.4(b) and (c) of the National Electrical Code for overcurrent protection of wire. D. Services on manufactured (mobile) homes shall be allowed when all of the following requirements are met: 1. Service will be of the meter and exterior main type of no less than one hundred twenty-five amps. 2. The manufactured (mobile) home is owner-occupied and not located on leased property. 3. The smallest conductor in the manufactured (mobile) home is #12 copper wire. 4. The manufactured (mobile) home is permanently set on a foundation designed to meet all of the local jurisdiction's requirements.

(Ord. 16-08 § 2, 2008; Ord. 14-05 § 1 (part), 2005; Ord. 8-02 § 2 (part), 2002; Ord. 6-96 § 1 (part), 1996; Ord. 4-93 § 1 (part), 1993: Ord. 7-90 § 1(12), 1990; Ord. 87-87 § 1 (part), 1987: prior code § 11-2(6))

Ask a question about Casper law

Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.