§ 15.28.220 — Raceways

Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 15.28.220

Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/937227f0-26e3-45fc-8807-6ec355b5838e

15.28.220 - Raceways.

A. Metal raceways shall be used for electric power, light, heat and all wiring supplying ninety volts and over in all commercial, industrial or public types of buildings, and in buildings or any part of buildings whose use is changed from residential to any other use. Armored cable shall be permitted for use in commercial buildings, for branch circuits, and shall be required to have a copper equipment grounding conductor as an integral part from the factory. B. Metal raceways are defined as galvanized rigid conduit (heavy-wall conduit) intermediate metal conduit, electrical metallic tubing (thin-wall conduit, metal molding, metal troughing, metal ducts, and flexible metallic conduit (as allowed by Section 15.28.320). Flexible metal conduit shall not be installed outdoors, exposed to weather. C. Fiberduct, PVC or equivalent raceways may be installed underground, and in concrete slabs, in accordance with the National Electrical Code. PVC may be installed in corrosive atmospheres by special permission from the city electrical inspector. D. PVC and electrical nonmetallic tubing (ENT) may be installed only in structures where combustible construction is allowed, including commercial and public buildings, with the following limitations: 1. ENT may be installed in buildings of no more than three floors. ENT shall not be permitted for exposed work, high temperature areas or exposed to physical damage. All bends in runs of ENT shall count in the total degrees of bend, which shall not exceed three hundred sixty degrees between boxes. 2. Bushings shall be installed when run in metal studs. 3. Metal plates of the proper type shall be used for protection of ENT, when run in wooden stud walls and unable to be run in the center of the stud. 4. Tie wire shall not be used as a strapping method for ENT. Article 362 of the National Electrical Code shall apply for other installation requirements. 5. PVC (rigid nonmetallic conduit) may be installed only in structures where combustible construction is allowed, and in accordance with Article 352 of the National Electrical Code, with the following limitations: PVC may be installed in slabs, and in buildings of no more than three floors. PVC shall not be permitted for exposed work (except as allowed by this section), high-temperature areas or exposed to physical damage. Short runs for protection of ground wires on exterior of buildings shall be permitted. All bends in runs of PVC shall count in the total degrees of bend, which shall not exceed three hundred sixty degrees between boxes. Metal plates of the proper type shall be used for protection of PVC when run in wooden stud walls and unable to be run in the center of the stud. Tie wire shall not be used as a strapping method for PVC. E. All raceways installed below grade shall have approved expansion joints installed within one foot immediately above grade on each end. All underground raceways shall have a sleeve installed where passing through concrete or masonry. A junction box shall be sized and constructed to power company requirements and may be above ground or underground, but in no case shall junction boxes be smaller than twelve inches wide by eighteen inches high by six inches deep above ground or thirteen inches by twenty-four inches by eighteen inches deep underground. Meter bases that provide room for eighteen inches of slack within the meter base shall not be required to have a junction box.

(Ord. 14-05 § 1 (part), 2005; Ord. 8-02 § 2 (part), 2002; Ord. 6-96 § 1 (part), 1996; Ord. 4-93 § 1 (part), 1993: Ord. 7-90 § 1(14), 1990; Ord. 87-87 § 1 (part), 1987: prior code § 11-2(2))

Ask a question about Casper law

Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.