Sec. 52.02. - Sanitary sewer connections.

I. Sewer Main Extension. To have a sanitary sewer extended in the City of Dayton, the applicant shall contact the Division of Water Engineering for current costs and procedures. Submittal/approval of plans, securing permits, and payment of applicable fees are required prior to any service work being started. To have a connection made in an available sewer, contact a licensed plumber. The plumber shall then contact the Division of Sewer Maintenance for current costs and procedures. Certain portions of building sewer lateral installations are performed by the city and billed to the licensed plumber or excavator. II. Connection to Sanitary Sewer Required. (A) Except as provided in this chapter, no person shall construct or maintain any privy, privy vault, septic tank, cesspool, or other facility intended or used for the disposal of wastewater. (B) The owner of any house, building, or property that is used for human occupancy, employment, recreation, or other purposes, and abutting on any street, alley, right-of-way, or easement in which there is or may be located a sanitary sewer connected to the treatment facility of the city, is required at the owner's expense to install suitable toilet facilities therein, and to connect such facilities by means of a building sewer (lateral) directly to the sanitary sewer in accordance with the provisions of this chapter, within 90 days after official notice to do so, provided that the proper sanitary sewer is within 200 feet of the property line. The owner is responsible for maintenance of the building sewer (lateral) to the point of connection with the publicly-owned sanitary sewer. This section shall not apply to any person served by a privately constructed, owned, operated, and maintained sanitary sewer and wastewater treatment facility that discharges directly to an outlet in accordance with the provisions of this chapter and applicable local, state, and federal laws. (C) This section shall not apply to any private system that discharges to wastewater facilities of the city or that discharges directly to a natural outlet by authority of a separate NPDES permit and in compliance with applicable local, state, and federal laws. (D) At such time as a sanitary sewer becomes available as defined above, to a property served by a private wastewater disposal system, a direct connection shall be made to the sanitary sewer within 90 days after official notice to do so, and any septic tanks, cesspools, and similar wastewater disposal facilities shall be emptied and filled with suitable material. III. Connection Approvals. (A) No person shall uncover, make any connections with or opening into, use, alter, or disturb any sanitary sewer or a storm sewer without first obtaining written approval from the Department of Building Services or Department of Water, as appropriate. (B) There may be four types of connections to the city's wastewater facilities: Residential, Commercial, Governmental, and Industrial. The Industrial User shall file an Application for Industrial Wastewater Service on a special form furnished by the Director. The application shall include wastewater disclosure information as required by the provisions of this chapter. Exceptions to this provision may be made by the Director. IV. Connection Costs. The costs and expenses incidental to the building sewer installation and connection to the city's wastewater facilities shall be borne by the owner. The owner shall indemnify the Director for any loss or damage incurred by the city that is directly or indirectly caused by the installation of the building sewer. Current rates for city connection are available at the Division of Sewer Maintenance, Division of Water Engineering, or the Department of Building Services ("One Stop Shop"). V. Separate Connections Required. A separate and independent building sewer shall be provided for every building separately owned. Except where one building stands at the rear of another on an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court yard, or driveway, the building sewer serving the front building may, upon the approval of the Director, be extended to the rear building and the whole considered as one building sewer. The Director assumes no obligation or responsibility for damage caused by or resulting from any single building sewer that serves two or more buildings. VI. Existing Building Sewers. Existing building sewers may be used for connection of new building only on approval of the Director. Submit exemption requests to the Division of Water Engineering. Exemption requests shall contain at a minimum the name and address of the owner of the property, billing responsibilities, and the reason for the exception. VII. Abandonment of Service. If a residential, commercial, governmental, or industrial structure is scheduled to be razed, then the service to the premises shall be cut and plugged at the property line as required by the Department of Water and the Department of Building Services. The actual cost will be incurred by the property owner. VIII. Building Sewer Design. The size, slope, alignment, construction materials, trench excavation, and backfill methods, pipe placement, jointing and testing methods used in the construction and installation of a building sewer shall conform to the building and plumbing code or other applicable requirements of the city. In the absence of code provisions or in amplification thereof, the materials and procedures set forth in appropriate specifications of the ASTM and WEF shall apply. IX. Building Sewer Elevation. Whenever practicable, the building sewer shall be brought to a building at an elevation below the basement floor. In buildings in which any building drain is too low to permit gravity flow to the city's sanitary sewer, wastewater carried by such building drain shall be lifted by an approved means and discharged to a building sewer draining to the city sewer. X. Surface Runoff, Groundwater, and Non-Contact Cooling Water Drains. No person shall connect roof, foundation, areaway, parking lot, roadway, or other surface runoff or groundwater or non-contact cooling water drains to any sewer that is connected to the city's wastewater facility. The Director may approve the connection of such drains only when he has explicitly approved the waters intended for such drains for discharge to the wastewater facility, under the provision found in § 52.03 II(B)(12). XI. Conformance to Applicable Codes. (A) The connection of a building sewer into a sanitary sewer shall conform to the requirements of the building and plumbing code or other applicable requirements of the city, or the procedures set forth in appropriate specifications of the ASTM or the WEF. The connections shall be made gas-tight and watertight and verified by proper testing. Any deviation from the prescribed procedures and materials shall be approved in writing by the Director before installation. (B) The connection of a surface runoff, groundwater, or non-contact cooling water drain to a storm sewer or outlet designed to transport surface runoff or groundwater drainage shall conform to the requirements of the applicable building code of the city and other applicable federal, state, and local requirements. XII. Connection Inspection. The applicant for a building sewer or other drainage connection permit shall notify the Director when such sewer or drainage connection is ready for inspection prior to its connection to the city's facilities. Such connection and testing as deemed necessary by the Director shall be made under the supervision of the Director. XIII. Excavation Guards and Property Restoration. Excavations for building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways, and other public property disturbed in the course of the work shall be restored in a manner satisfactory to the Director. XIV. Allocation of Capacity. The Director shall not accept discharges of any wastewater to the city's sanitary sewers or wastewater treatment facilities unless there is sufficient capacity in the sanitary sewers and treatment facilities to convey and adequately treat the quantity of wastewater that the requested connection will add to the system. Where the Director determines that a discharge from a new source will utilize an unreasonable proportion of the reserve capacity of the sanitary sewers or wastewater treatment facilities, the Director shall not accept the discharge from the new source.

(Ord. 30739-08, passed 4-23-08)

Ask a question about Dayton law

Corpus searches the Dayton sections it holds and shows the ones that match, with their citations. Free, no sign-in.