Sec. 49-1902. - Electrical specifications.
For lengths shorter than 500 feet, electric wiring shall be a minimum 18-gauge UL approved underground feed multi-strand. For lengths exceeding 500 feet, a minimum of 14-gauge UL approved underground feed wire shall be required. The following provisions shall also apply:
(a) Any underground electrical connection shall be made by an approved waterproof connection.
(b) All 12-volt and 24-volt wiring shall be installed by the licensed lawn sprinkler contractor
(c) All controllers with an internal transformer requiring hard wiring directly into circuit wiring shall have the wire installed by a licensed electrician and shall have a disconnect switch installed at the controller
(d) All underground electric or hydraulic control valves shall be installed in a valve boxes.
(e) All exposed irrigation circuit wires above grade, before entering a structure, shall be encased in an approved electrical raceway.
(f) If a master valve is installed inside a building, it should be brass and operated by a 24-volt solenoid.
(Ord. No. 40524, § 1, 10-20-15)