§ 153.164. - Water supply.

(a) Public water supply. (1) Public water supply within the jurisdiction of this chapter shall be designed or the design approved by the water division. New development within the City of Springfield shall be supplied by City of Springfield (CWLP) water mains. (2) All water mains within the jurisdiction of this chapter shall be installed to the water division's design standards. The size and depth of bury of mains, approved main materials, number, type and location of valves and hydrants, and other design details shall be reviewed and are subject to the approval of the water division. The CWLP superintendent of water engineering may require evidence that the proposed development will not reduce system conditions below acceptable levels in any portion of the water system. The superintendent of water engineering will not approve an addition to any water system that could cause a violation of the Environmental Protection Act, the IEPA Technical Policy Statements or other regulations. (3) Water mains not less than six inches in diameter shall be constructed throughout the entire subdivision. Installation and sterilization of all water mains shall be in accordance with the latest revised edition of the Standard Specifications for Water and Sewer Main Construction in Illinois. Specific attention shall be given to the standard specifications' separation requirements between water mains and sanitary or storm sewers. Flyash may not be used as backfill material within ten feet of an existing or proposed iron water main. (4) Every water supply system shall be designed in such a manner as to provide adequate fire suppression capability for the development. This requirement will be primarily determined by American Water Works Association (AWWA) Manual M31; "Distribution System Requirements for Fire Protection." Water mains larger than six inches in diameter shall be installed at the Subdivider's expense if needed to provide the area fire flow required. (Note the following chart). Fire hydrants with shut-off valves at each hydrant shall be installed throughout the entire system at maximum intervals of 500 feet or less as required by the fire department fire safety division. All fire hydrants shall be three nozzle hydrants. The fire suppression requirements for industrial, commercial or multi-family developments are discussed in AWWA Manual M31. Needed Fire Flow for One- and Two-Family Dwellings* Distance Between Buildings (In Feet) | Needed Fire Flow (GPM) Over 100 | 500 31 to 100 | 750 Under 31 | 1,000 *Dwellings not to exceed two stories in height. Residual pressures are to be held at a minimum of 20 PSI during the calculated fire demand. The needed fire flow must be available for a firm duration of two hours at a time of peak system demand. The impact of a proposed development on existing areas shall also be considered. (b) Private water supply. When a private water supply is allowed (See section 153.112(a)(2)), a private well may be used. Wells shall be constructed according to the Illinois Water Well Pump Installation Code. The fire protection requirements of section 153.112(a)(3)(c) must still be provided. The city is not responsible for certifying the adequacy of the area to support individual wells.

(Ord. No. 804-10-93, § 1(Exh. A), 10-19-93; Ord. No. 264-07-12, § 1(Exh. A), 7-17-12)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.