§ 169.06 — Land Alteration Requirements
Code of Ordinances of the City of Fayetteville, Arkansas (Codified through Ordinance No. 7010, enacted June 16, 2026 (Supp. No. 42)) · Fayetteville Code of Ordinances § 169.06
Corpus is an independent public-information project, not the official City of Fayetteville website. Stable reference: corpuslaw.us/code/ac33999e-c88f-4760-a83f-e0ed4c491d4c
169.06 - Land Alteration Requirements
(A) Applicability. This section shall apply to all land alteration activities, including those that do not require a grading permit. (B) Requirements Varied. Variances of this chapter's requirements may be approved by the City Engineer. The extent to which variations may be made will depend on the soil types encountered, planned slopes, planned vegetation, and investigative engineering reports. In no case shall the City Engineer waive or modify any of the minimum erosion control requirements as given in §169.04. (C) Cut or Fill Slopes. (1) Finish Grade. Cut or fill slopes shall have a finish grade no steeper than 33% (3.00 horizontal to 1 vertical), unless otherwise approved by the City Engineer. Land located within the Hillside/Hilltop Overlay District may have cut or fill slopes with a finish grade no steeper than 50% (2.00 horizontal to 1 vertical) unless otherwise approved by the City Engineer. (2) Maximum Length. The maximum length of any cut or fill slope without a terrace (as described in §169.06(D) and (E) below) shall be 100 feet as measured along the ground. The terrace shall be at least 6 feet wide. (3) Existing Topography. Cut or fill slopes shall be constructed to eliminate sharp angles of intersection with the existing terrain and shall be rounded and contoured to blend with the existing topography. (4) Setback Requirements. The following setback requirements shall be reviewed by the City Engineer for purposes of assessing safety, stability, and drainage problems: (See illustrations). (a) Setback from Top or Toe of Cut or Fill. Buildings shall be setback from the top or toe of a cut or fill in accordance with Zoning, Chapters 160 through 165; Building Regulations, Chapter 173; or the approved grading plan, whichever is greatest. (b) Setbacks from Property Lines. The required setback of retaining walls, cut slopes, and fill slopes from property lines shall be as given in the illustrations. Property lines may be filled over or cut if a grading plan for the cut or fill is submitted jointly by the owner of both properties or with written permission from the adjacent property owner and if no utility easements are involved. If utility easements are involved, approval is required as given in (c) below in addition to the joint submittal requirement. (c) Setbacks from the Edge of an Easement. The required setback of retaining wall, cut slopes, and fill slopes from the edge of easements shall be as given in the illustrations. Where no utilities are present in an easement, or where utilities are planned to be relocated, and where such action is approved by all utilities, in writing, then easements may fall within a cut or fill section. (d) Setbacks from Structures. The required setback of retaining walls, cut slopes, and fill slopes from structures shall be as given in the illustrations. If a structure forms an integral part of the retaining wall, then the setbacks do not apply to that structure. (e) Calculating Setbacks. For the purpose of calculating setbacks, any cut or fill section which is on a slope of one (1) to one (1) or greater shall be considered a retaining wall. (f) Administrative Variance. Setbacks from easement lines and structures may be varied administratively by the City Engineer if geotechnical and/or structural information is provided that in the opinion of the City Engineer justifies the variance. (g) Additional Information Required. The City Engineer may require further geotechnical and/or structural information to show that setbacks greater than those given are not needed to protect property, utilities, or the integrity of property lines. (D) Cuts. (1) Vertical Height. Cuts shall be limited to 10 feet in vertical height unless information demonstrating slope stability, erosion control, and drainage control is provided together with a re-vegetation plan. For nonsolid rock cuts, terraces shall be required for cuts greater than 10 feet in height. It is recommended that terracing be at a maximum ratio of 1 foot of horizontal terrace for every foot of vertical surface. (2) Maximum Vertical Cut. In solid rock, as determined by geotechnical and engineering data approved by the City Engineer, the maximum vertical cut shall be 30 feet. (3) Fill Material. In no case shall a cut be allowed primarily for the purpose of obtaining fill material to a different site, unless the exporting site is located within an extraction district. (E) Fills. (1) Rocks/Fill. All imported fill shall be free of rocks greater than twelve (12) inches in diameter and any detrimental organic material or refuse debris. (2) Compaction. Fill shall be placed and compacted as to minimize sliding or erosion of soil. Fill compaction shall equal the compaction of undisturbed, adjacent soil, except fills covered by Building Regulations, Chapter 173, or other structural fills. The City Engineer may require soil tests during compaction work or upon its completion at the expense of the permittee. (3) Grade. Fill shall not be placed on existing slope with a grade steeper than 15% (6.67 horizontal to 1 vertical) unless keyed into steps in the existing grade and thoroughly stabilized by mechanical compaction. (4) Vertical Height. Fills shall be limited to 10 feet in vertical height unless information demonstrating slope stability, erosion control, and drainage control is provided together with a re-vegetation plan. (5) Terraces. Terraces shall be required for fills greater than 10 feet in height. It is recommended that terracing be at a maximum ratio of one foot of horizontal terrace for every foot of vertical surface. (F) Erosion and Sedimentation Control. (1) Permanent Improvements. Permanent improvements such as streets, storm sewers, curb and gutters, and other features for control of runoff shall be scheduled coincidental to removing vegetative cover from the area so that large areas are not left exposed beyond the capacity of temporary control measures. (2) Phased Construction. The area of disturbance onsite at any one time shall be limited to 10 acres. An additional 10 acres (a maximum of 20 acres of disturbance at any one time) may be stripped with the permission of the City Engineer in order to balance cut and fill onsite. No additional area may be open without the permission of the City Engineer until the previously disturbed areas have been temporarily or permanently stabilized. (3) Stockpiling of Top Soil. Top soil may be stockpiled and protected for later use on areas requiring landscaping. All storage piles of soil, dirt or other building materials (e.g., sand) shall be located more than 25 feet from a roadway, drainage channel or stream (from top of bank), wetland, and stormwater facility. The City Engineer may also require top soil stockpiles to be located up to 50 feet from a drainage channel or stream, as measured from the top of the bank to the stockpile, for designated protected streams; established TMDL water bodies; streams listed on the State 303(d) list; an Extraordinary Resource Water, Ecologically Sensitive Waterbody, and/or Natural and Scenic Waterbody, as defined by Arkansas Pollution Control and Ecology Commission Regulation No. 2; and/or any other uses at the discretion of the City Engineer. Topsoil piles surfaces must be immediately stabilized with appropriate stabilization measures. Stabilization practices may include: temporary seeding (i.e. annual rye or other suitable grass), mulching, and other appropriate measures. Sediment control measures such as buffer strips, wattles, or silt fence shall be provided immediately for stockpiles and remain in place until other stabilization is in place. Storm drain inlets must be protected from potential sedimentation from storage piles by silt fence or other appropriate barriers. Properly stabilized topsoil stockpiles may be used for sedimentation control. (4) Plant/Water. Plant materials shall be watered or irrigated and tended. Where irrigation or regular watering is not available, only native or acclimated plant species shall be used. If the soil cannot properly sustain vegetation, it must be appropriately amended. If re-vegetation is not firmly established and healthy after one (1) year, the urban forester shall require that it be redone in part or total. (5) Permanent Erosion Control. The developer shall incorporate permanent erosion control features at the earliest practical time. Temporary erosion control measures will be used to correct conditions that develop during construction that were unforeseen during the design stage, that are needed prior to installation of permanent erosion control features, or that are needed temporarily to control erosion that develops during normal construction projects, but are not associated with permanent control features on the project. (G) Percentage of Land Disturbance. Land disturbance percentage within the Hilltop/Hillside Overlay District shall be equal to with the percent minimum canopy required on site per Chapter 167, Tree Preservation and Protection. (H) Required Retaining Wall and Rock Cut Design. (1) Design/Inspection. Any retaining wall more than 4 feet in height shall be designed by an Arkansas registered professional engineer, and shall be field inspected by the design engineer. The design engineer shall provide proof of inspection and certify that the wall was constructed in conformance with the design. The City Engineer may require retaining walls less than 4 feet in height to be designed by a professional engineer. (2) Investigation/Report. All proposed rock cuts and any cut or fill 10 feet or greater will require a geotechnical investigation and a formal report submitted by a registered professional engineer qualified to make such investigations. (3) Safety Railings. Safety railings may be required on any retaining wall 2.5 feet or higher. The decision as to whether to require safety railing shall be based on potential pedestrian and public access to the retaining wall and applicable building codes. This requirement for safety rails shall also apply to vertical or near vertical rock cuts and to steep (greater than 3:1) cut or fill slopes. [image omitted; see the official code] [image omitted; see the official code]
(Code 1991, §161.07; Ord. No. 3551, 6-4-91; Ord. No. 4100, §2 (Ex. A), 6-16-98; Ord. No. 4113, §1, 8-18-98; Ord. No. 4855, 4-18-06; Ord. No. 5336, 8-3-10; Ord. No. 5431, 8-16-11; Ord. No. 5702, Repealed & Replaced Chp. 169, 8-5-14; Ord. No. 6061, §6, 4-17-18; Ord. No. 6446, §11(Exh. F), 6-15-21)
Ask a question about Fayetteville law
Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.