169.07 - Grading Plan Specifications

(A) Grading Plan. The applicant shall prepare a grading plan for all developments of greater than 6,001 square feet of impervious area as follows: (1) Site Plan. Site plan showing property lines; vicinity map; name of owner, developer and adjacent property owners. (2) Existing Grades. Existing grades shall be shown with dashed line contours and proposed grades with solid line contours. Grading plans shall be required to show both the proposed grade and the undisturbed area. Contour intervals shall be a maximum of 2 feet. Spot elevations shall be indicated. (3) Designation of Grade. Areas with 0 to 10%, 10 to 15%, 15 to 20% and more than 20% grade shall each be identified in a distinguishing manner. (4) Identify Land to Be Disturbed. Land areas to be disturbed shall be clearly identified. (5) Engineer/Architect. Seal of an Arkansas registered engineer or landscape architect certifying that the plan complies with this chapter. (6) Cuts and Fills. All cuts and fills, including height and slope, shall be clearly shown on the plan. (7) Streets and Rights-of-Way. Location and names of all existing or platted streets or rights-of-way within or adjacent to tract and location of all utilities and easements within or adjacent to the property shall all be indicated. (8) Lot/Building, Etc., Identification. The proposed location of all impervious areas, including but not limited to buildings, streets and parking lots, shall be indicated as well as parks, playgrounds or green space. Any existing or proposed building within 100 feet of the site boundary shall be indicated. (9) Natural Features. Location of natural features such as drainage ways, ponds, rock outcroppings, wetlands and tree cover. Indication of 100-year floodplains as defined by FEMA. (10) Streets and Drainage Ways. Profiles and cross sections for proposed streets and drainage ways. (11) Acreage. Total project acreage, temporary disturbed area and permanent impervious area. (12) Surface Water. Provisions for collecting and discharging surface water in accordance with the Drainage Criteria Manual. (13) Underground Utilities. Profiles and cross sections of streets, drainage systems, and underground utilities, if they are necessary to clarify the grading plan in terms of potential erosion or runoff, or if the grading on site has the potential of disturbing the utility line. (14) Treatment of Slopes and Benches. The method of treatment for all slopes and benches shall be indicated, including final cover type. (15) Natural Vegetation Preservation. Proposals for preserving natural vegetation and description of re-vegetation or other permanent erosion control strategy. (16) Runoff/Sedimentation. Specification of measures to control runoff and sedimentation during construction indicating what will be used such as silt fences, silt dams, rock check dams, lateral hillside ditches, catch basins, and the like. (17) Preliminary Plat Master Build-Out Grading Plan. The applicant shall prepare a master grading plan to be followed during individual lot development to convey runoff to a public drainage easement or right-of-way. The following shall be required for individual lot drainage design: (a) Identify lot lines and conceptual foot print of residence. (b) Indicate individual lot drainage with the use of contours and flow arrows or other indications of direction of drainage. (i) In general, drainage should be routed on the shortest practicable flow path to the public right-of-way or drainage easement. (c) Nonstructural grassed swales for rear lot drainage concentration is discouraged and shall not be installed in combination with a utility easement. (d) Right-of-way, utility easements and drainage easements shall be graded and shaped in accordance with the master build out grading plan during preliminary plat construction. (i) Utility easements adjacent to the right-of-way shall be no steeper than 15%. (ii) Provisions will be considered to accommodate positive drainage until build-out occurs. (B) Preliminary Grade Plan. The preliminary grading plan shall have adequate detail for review.

(Code 1991, §161.08; Ord. No. 3551, 6-4-91; Ord. No. 4100, §2 (Ex. A), 6-16-98; Ord. No. 4113, 8-18-98; Ord. No. 4855, 4-18-06; Ord. No. 5336, 8-3-10; Ord. No. 5702, Repealed & Replaced Chp. 169, 8-5-14; Ord. No. 6061, §7, 4-17-18; Ord. No. 6446, §11(Exh. F), 6-15-21)

Ask a question about Fayetteville law

Corpus searches the Fayetteville sections it holds and shows the ones that match, with their citations. Free, no sign-in.