§ 9.0 — Inspection and testing
Municipal Code of the City of Fort Smith, Arkansas (Codified through Ordinance No. 126-24, enacted December 3, 2024. (Supp. No. 4)) · Fort Smith Municipal Code § 9.0
Corpus is an independent public-information project, not the official City of Fort Smith website. Stable reference: corpuslaw.us/code/1d735b80-16a1-4b4f-b9ba-963d267684d5
9.0 - Inspection and testing.
9.1 General. Materials and construction employed in street improvements will be subject to inspection and quality control testing. All inspection and testing shall be provided by the Developer except as otherwise stated herein. 9.2 Inspection. 1. Inspection By Developer - The Developer shall provide for inspection of the street improvements during construction. Inspection shall be accomplished under the supervision of the Engineer. The Engineer will provide certification that all materials and construction conform to the approved plans and specifications. 2. Inspection By City - The construction of street improvements will be subject to inspections by the City at various stages including, but not limited to, subgrade, base course and surfacing. An inspection for a particular stage will not be conducted until the pertinent test data has been submitted. Scheduling of construction shall provide sufficient time for review of test data and scheduling inspections. A representative of the engineering firm responsible for the project shall be present at the inspections. A construction inspection checklist is included in Appendix A and is required to be submitted as part of the final approval process. 9.3 Quality Control Testing. The Developer shall provide quality control testing for all materials and construction involved in the street improvements. All testing shall be accomplished by a testing firm that meets the requirements of a Qualified Laboratory and shall be performed under the supervision of an Engineer. Minimum test requirements and minimum frequency of sampling and testing shall be as shown in Table 10. Projects will be evaluated individually, and additional testing may be required. Tolerances shall be in accordance with the City of Fort Smith Standard Specifications. In general, deficiencies in quality of materials and/or construction exceeding the tolerance limits will not be approved. Submission of test results shall be coordinated with the various stages of construction. Sampling and testing locations will be subject to approval of the City. Exceptions to the number of required tests for materials may be granted at the discretion of the City when current test data are available. Table 10: Minimum Test Requirements CONSTRUCTION QUALITY CONTROL Construction Stage | Test Required | Test Referencea | Frequency of Sampling and Testing AASHTO | ASTM | ARDOT Subgrade Sampling | T 87 | D 421 | —- | One/Type of Soil Soil Classification | M 145 | —- | —- Sieve Analysis | T 88 | D 422 | —- Moisture-Density Relationship | Standard Proctor or | T 99 | D 698 | —- Modified Proctor | T 180 | D 1557 | —- Moisture & Density (In-Place) | T 310 | D 6938 | —- | One/750 SY/8" Lift (Subgrade) b One/750 SY/8" Lift (fill) One/300 LF/12" Lift (Trench Backfill) c One/Crossing/12" Lift (Trench Backfill) c One/750 SY/12" lift (Structure Backfill) c —- —- —- —- Base Course Aggregate Base Course Sampling | T 2 | D 75 | —- | One/Type of Aggregate Percentage of Wear | T 96 | C 131 | —- Soundness | T 104 | C 88 | —- Sieve Analysis | T 27 | C 136 | —- Moisture-Density Relationship | T 180 | D 1557 | —- Moisture & Density (In-Place) | T 310 | D 6938 | —- | One/750 SY/8" Lift b Thickness | —- | —- | —- ACHM Base Course (Refer to ACHM Surfacing) Curb & Gutter Portland Cement Concrete Sampling | T 141 | C 172 | —- | One/1000 LF of Curb & Gutter Slump | T 119 | C 143 | —- Temperature | —- | —- | —- Air Content | T 152 | C 231 | —- Cylinders | T 22/T 23 | C 39/C 31 | —- | One Set (4)/1000 LF of Curb & Gutter Asphalt Concrete Hot Mix (ACHM) Aggregates Sampling | T 2 | D 75 | —- | One/Source of Material Percentage of Wear | T 96 | C 131 | —- Soundness | T 104 | C 88 | —- Sieve Analysis | T 27 | C 136 | —- Bituminous Mixture Sampling | T 168 | —- | 465 | One/Type of Mixture Stability | T 45 | —- | —- Air Voids (AV) | T269 | —- | —- Voids in Mineral Aggregate (VMA) | —- | —- | 464 Water Sensitivity | —- | —- | 455 Density - Maximum Theoretical | T 209 | —- | —- Density (Field) | T 166 | —- | 461 | One/750 SY b Thickness (Core) | —- | —- | —- Asphalt Binder Content | —- | —- | 449/449A | One/500 TN d,e Aggregate Gradation | T 30 | C 136 | 460 | One/750 TN d,e Portland Cement Concrete Pavement and Structuresf Aggregates Sampling | T 2 | D 75 | One/Source of Material Organic Impurities | T 21 | C 40 Sieve Analysis | T 27 | C 136 Percentage of Wear | T 96 | C 131 Soundness | T 104 | C 88 Friable Particles | T 112 | C 142 Concrete Mixture Sampling | T 141 | C 172 | —- | One/100 CY Slump | T 119 | C 143 | —- Temperature | —- | —- | —- Air Content | T 152 | C 231 | —- Cylinders | T 22/T 23 | C 39/C 31 | —- | One Set (4)/100 CY e Thickness (Core) | T 24 | C 42 | —- | One/1000 LF/Lane b a Additional Tests not listed herein may be referenced within the AASHTO or ASTM procedures. b A minimum of one test required for each individual street, cul-de-sac and intersection. c Trench and structure backfill tests are in addition to subgrade tests. d Not less than one test per day. e A minimum of one test required for each type of material or mixture. f Structures includes concrete aprons and swales, drainage structures, driveways, sidewalks, etc.
Ask a question about Fort Smith law
Corpus searches the Fort Smith sections it holds and shows the ones that match, with their citations. Free, no sign-in.