§ 24-1 — Definitions

Municipal Code of the City of Avondale, Arizona (Codified through Ordinance No. 2021-0726, adopted July 6, 2026 (Supp. No. 38, Update 1)) · Avondale Municipal Code § 24-1

Corpus is an independent public-information project, not the official City of Avondale website. Stable reference: corpuslaw.us/code/e0edb01c-eeab-4f6f-8e79-f0a54e5624f5

24-1 - Definitions.

The following words, terms and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: "Air gap (AG)" is the unobstructed vertical distance through the free atmosphere between the opening of the pipe or faucet supplying potable water to a tank, plumbing fixture, or other device. An approved air gap shall be at least double the effective opening of the supply piping or faucet and in no case less than one (1) inch above the flood rim. "Approved backflow prevention assemblies" mean assemblies that have been manufactured in full conformance with the standards established by the American Water Works Association entitled: AWWA/ANSI C 510-2007 Standard for Double Check Valve Backflow Prevention Assembly and AWWA/ANSI C511-2007 Standard for Reduced-Pressure Backflow Prevention Assembly and have met completely the laboratory and field performance standard of the Foundation for Cross-Connection Control and Hydraulic Research of the University of Southern California (USC FCCCHR) established in Chapter 10 of the most current edition of the Manual of Cross-Connection Control (Standards of Backflow Prevention Assemblies). "Backflow" is the undesirable reversal of flow of non-potable water or other substance through a cross-connection and into the piping of a public water system or consumer's potable water system. There are two types of backflow: backpressure backflow and backsiphonage. "Backflow prevention method" means an assembly or other means designed to prevent backflow. "Backpressure backflow" is backflow caused by a downstream pressure that is greater than the upstream or supply pressure in a public water system or consumer's potable water system. Backpressure (i.e., downstream pressure that is greater than the potable water supply pressure) can result from an increase in downstream pressure, a reduction in the potable water supply pressure, or a combination of both. Increases in downstream pressure can be created by pumps, temperature increase in boilers, etc. Reductions in potable water supply pressure occurs whenever the amount of water being used exceeds the amount of water being supplied, such as during water line flushing, firefighting, or breaks in water mains. "Backsiphonage" is backflow caused by a negative pressure (i.e., vacuum or partial vacuum) in a public water system or consumer's potable water system. The effect is similar to drinking water through a straw. Backsiphonage can occur when there is a stoppage of water supply due to nearby firefighting, a break in a water main, etc. "Bypass" means the intentional diversion of water from any portion of a customer's or unauthorized user's connection to the city's potable water. "Certified tester" is someone trained and certified through a certification program approved by the American Backflow Prevention Association with proper training in the most current edition Manual of Cross-Connection Control test procedures and approved by the City of Avondale. "Contamination" means any condition, device or practice which, in the judgment of the Department, may create a danger to public's health and well-being. This includes an impairment of the public water supply by the introduction or admission of any foreign substance that degrades the water quality and creates a health hazard. "Cross connection" is any temporary or permanent connection between a public water system or consumers' potable (i.e., drinking) water system and any source or system containing non-potable water or other substances. An example is the piping between a public water system or consumers' potable water system and an auxiliary water system, cooling system, or irrigation system. "Customer" means a person or entity with a valid city water account. "Department" means the Avondale Public Works Department. "Director" is the individual in charge of the Avondale Public Works Department and its daily operations or his authorized designee. "Double check detector assembly (DCDA or DDCVA)" means an assembly composed of a line-size approved double check valve assembly with a bypass containing a specific water meter and an approved double check valve assembly. "Double check valve assembly (DCVA)" means an assembly composed of two independently acting, approved check valves, including tightly closing shutoff valves located at each end of the assembly and fitted with properly-located test cocks. "Potable water supply" is raw or treated water that is considered safe to drink. "Pressure vacuum breaker assembly (PVB)" means an assembly containing an independently operating, loaded check valve and an independently operating, loaded air inlet valve located on the discharge side of the check valve. The assembly shall be equipped with properly located test cocks and tightly closing shutoff valves located at each end of the assembly. "Reduced-pressure assembly (RPA)" means an assembly containing two (2) independently-acting, approved check valves together with a hydraulically operating, mechanically independent pressure differential relief valve located between the check valves, and below the first check valve. The assembly shall include properly located test cocks and tightly closing shutoff valves located at each end of the assembly. "Reduced-pressure detector assembly (RPDA)" means an assembly composed of a line-size approved reduced-pressure assembly with a bypass containing a specific water meter and an approved reduced-pressure assembly. "Spill-resistant pressure vacuum breaker (SVB)" means an assembly containing an independently operating, internally loaded check valve and independently operating, loaded air inlet valve located on the discharge side of the check valve. The assembly shall be equipped with a properly located resilient seated test cock, properly located bleed/vent valve and tightly closing resilient seated shutoff valves located at each end of the assembly. "Water service connection" is any direct connection to the City of Avondale potable water system. (Ord. No. 1572-315, § 2, 3-16-15)

Ask a question about Avondale law

Corpus searches the Avondale sections it holds and shows the ones that match, with their citations. Free, no sign-in.