§ 24-7 — Installation requirements; location
Municipal Code of the City of Avondale, Arizona (Codified through Ordinance No. 2021-0726, adopted July 6, 2026 (Supp. No. 38, Update 1)) · Avondale Municipal Code § 24-7
Corpus is an independent public-information project, not the official City of Avondale website. Stable reference: corpuslaw.us/code/16d8c4ba-e23e-4f87-8dec-7acffa606a1f
24-7 - Installation requirements; location.
(a) Only approved backflow prevention assemblies may be installed and only upon receipt of the necessary city backflow permit. (b) An approved backflow prevention assembly shall be installed by the customer, at the customer's expense and in compliance with the standards and specifications adopted by the city, as close to the water service connection as possible. (c) The assembly shall be in an accessible location approved by the department. A reduced-pressure assembly and a pressure vacuum breaker assembly shall be installed above grade level between twelve (12) and twenty-four (24) inches. A double check valve assembly may be installed, at the customer's option, below ground in a vault that meets standards and specifications established by the city. (d) The assembly shall have a diameter at least equal to the diameter of the water service connection. (e) When a customer desires a continuous water supply, two (2) or more backflow prevention assemblies shall be installed parallel to one another at the water service connection to allow a continuous water supply during testing of the backflow prevention assemblies. When backflow prevention assemblies are installed parallel to one another, the sum of the areas of the diameters of the assemblies shall be at least equal to the area of the diameter of the water service connection. (f) Following the installation of any assembly, the customer must have an initial test on the assembly and have it inspected by the department before the certificate of occupancy can be issued. (g) All assemblies shall be equipped with gate valves on both the upstream and downstream side of the assembly. In addition, test cocks shall be provided so that test equipment may be connected to the assembly at such points that the pressure in each pressure zone may be detected. (h) Except as provided in subsection 24-13(b) below, it shall be unlawful, and punishable as a misdemeanor as set forth in section 1-9(c) of the City Code, to bypass a backflow prevention method. (Ord. No. 1572-315, § 2, 3-16-15)
Ask a question about Avondale law
Corpus searches the Avondale sections it holds and shows the ones that match, with their citations. Free, no sign-in.