§ 18.205.340 — Design standard – Setbacks
Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 18.205.340
Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/2a31f324-7a68-4eaa-8219-c16a569b3d8e
18.205.340 Design standard – Setbacks.
(a) Minimum setbacks for tops of graded slopes or toes of graded slopes from each other, from existing or proposed buildings, or from property lines, shall be as set forth in the following diagram and chart. The setbacks shown, however, are minimum requirements, and may be increased by the reviewing agency or the city engineer when it is determined that such additional requirement is necessary for stability of the site; for safety; or to prevent future damage from water, soil or debris. MINIMUM REQUIRED SETBACKS | | A | B | C | D | Excavation or Fill of “H” Feet | Fill Slopes | Excavated Slopes | | 0 – 3 ft. | 0 ft. | 5 ft. | 0 ft. | 0 ft. | 5 ft. | 3 – 15 ft. | 3 ft. | 5 ft. | 10 ft. | 0 ft. | 5 ft. | 15 – 50 ft. | H/10 ft. 3 ft. min. | H/5 ft. 5 ft. min. | 10 ft. | 6 ft. | H/5 ft. 5 ft. min. | Over 50 ft. | H/10 ft. | H/5 ft. | 10 ft. | 6 ft. | 10 ft. (b) Applicability of Section. Insofar as they can be made applicable, the provisions of this section shall apply to all grading in the city regardless of whether a permit is required by this chapter for such grading. (Ord. 9-2014 § 29, 3-4-14.)
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.