§ 3-1.203 — Fire Protection and Water Supplies
Modesto Municipal Code (Supp. No. 72: codified through Ordinance No. 3813-C.S. effective May 12, 2026) · Modesto Municipal Code § 3-1.203
Corpus is an independent public-information project, not the official City of Modesto website. Stable reference: corpuslaw.us/code/4d2cd627-aa6a-4f29-9c2c-4e29c93dc910
3-1.203 - Fire Protection and Water Supplies.
Section 507.5 of the 2025 California Fire Code is hereby adopted by reference, in addition to the following: Fire hydrant systems. Fire hydrant systems shall comply with section 507.5.1 through 507.5.6 and Appendix C or by an approved method. Fire hydrants shall be located on the supply side of the fire suppression system check valve and accessible from the apparatus roads in compliance with Section 503.1 and Appendix D. The fire code official my require a looped underground fire service for large projects when deemed necessary. Section 507.5.1 of the 2025 California Fire Code is hereby adopted by reference, in addition to: Where required. When a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than three hundred (300) feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains shall be provided where required by the fire code official. Exception: For Group R-3 and Group U occupancies equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3, the distance requirement shall be not more than five hundred (500) feet. Section 507.5.1.1 of the 2025 California Fire Code is hereby adopted by reference, and amended to read as follows: Hydrants for Standpipe systems. Buildings equipped with a standpipe system installed in accordance with section 903 shall have a fire hydrant within seventy-five (75) feet of the fire department connection. Section 507 of the 2025 California Fire Code is hereby added and shall read as follows: Spacing. Fire hydrants shall be spaced nominally every five hundred (500) liner feet in residential areas and three hundred (300) liner feet in commercial or industrial areas and shall comply with city building standards. Divided streets shall have hydrants on both sides of the street and shall, where applicable, be installed in alternative or staggered positions so that hydrants will not be directly opposite from each other. Section 905.3.1 of the 2025 California Fire Code is hereby adopted by reference, with the addition of the following: Height. Occupancies three (3) or more stories in height shall be provided with a Class 1 standpipe system approved by the Fire Chief. (Except Group R-3 and R-3.1) Garden type apartment complexes may be required to install Class 1 standpipe systems approved by the Fire Chief. Section 912 of the 2025 California Fire Code is hereby added to read as follows: A fire hydrant shall be located within seventy-five (75) feet of all required fire department connections. Fire hydrants serving sprinkler systems shall be located on the City side of the back flow prevention device.
(Ord. No. 3802-C.S, § 1, effective 1-8-26)
Ask a question about Modesto law
Corpus searches the Modesto sections it holds and shows the ones that match, with their citations. Free, no sign-in.