3-1.235 - Appendix D.
Appendix D Section D101.1 of the California Fire Code is hereby adopted by reference, in addition to the following: Appendix D shall only be enforced on private roadways, property and streets not public roadways. Appendix D Section D103.5(1) of the California Fire Code is hereby adopted by reference, in addition to: Where a fire apparatus road consists of a divided roadway, the gate width shall not be less than fifteen (15) feet. Appendix D Section D103.5(5) of the California Fire Code is hereby adopted by reference, in addition to: Electric gates shall be operable by means of a Knox key switch accessible by both police and fire. Electric gates at housing complexes, gated communities or rental storage facilities shall also be dual equipped with Opticom strobe light system or as required by the Fire Chief. All Gate shall automatically open upon power failure. Appendix D Section D103.5(6) of the California Fire Code is hereby adopted by reference, in addition to: Manual opening access gates may not be locked with a chain and padlock unless a Knox padlock is installed in the chain. Dual keyed access for the Police Department shall be required.
(Ord. No. 3802-C.S, § 1, effective 1-8-26)