§ 8.04.755: Amendments to Chapter 5 of the Palmdale Residential Code.

Chapter 5, Floors, of the Palmdale Residential Code as adopted by incorporation of the California Residential Code is hereby modified as follows: Section R503.2.4 is added to Chapter 5 of the 2025 Edition of the California Residential Code to read as follows: R503.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms with a dimension perpendicular to the joist that is greater than 4 feet (1.2 m) shall be constructed in accordance with Figure R503.2.4. [image] a. Blockings shall be provided beyond headers. b. Metal ties not less than 0.058 inch [1.47 mm (16 galvanized gage)] by 1.5 inches (38 mm) wide with eight 16d common nails on each side of the header-joist intersection. The metal ties shall have a minimum yield of 33,000 psi (227 MPa). c. Openings in diaphragms shall be further limited in accordance with Section R301.2.2.6. FIGURE R503.2.4OPENINGS IN HORIZONTAL DIAPHRAGMS

( Ord. 1595 § 1 (Exh. A), 2022 ; Ord. 1661 , 10/21/2025 )