§ 8.04.757 — Amendments to Chapter 8 of the Palmdale Residential Code
Municipal Code, City of Palmdale, California (Code 2026-05-05) · Palmdale Municipal Code § 8.04.757
Corpus is an independent public-information project, not the official City of Palmdale website. Stable reference: corpuslaw.us/code/60d3c879-cae9-48d4-9c49-c9f40e7fd7b0
§ 8.04.757: Amendments to Chapter 8 of the Palmdale Residential Code.
Chapter 8, Roof-Ceiling Construction, of the Palmdale Residential Code as adopted by incorporation of the California Residential Code is hereby modified as follows: Section R802.8 of the 2010 Edition of the California Residential Code is amended to read as follows: R802.8 Lateral support. Roof framing members and ceiling joists having a depth-to-thickness ratio exceeding 2 to 1 based on nominal dimensions shall be provided with lateral support at points of bearing to prevent rotation. For roof rafters with ceiling joists attached per Table R602.3(1), the depth-thickness ratio for the total assembly shall be determined using the combined thickness of the rafter plus the attached ceiling joist.
( Ord. 1410 § 2 (Exh. A), 2010 )