§ 8.04.756 — Amendments to Chapter 6 of the Palmdale Residential Code

Municipal Code, City of Palmdale, California (Code 2026-05-05) · Palmdale Municipal Code § 8.04.756

Corpus is an independent public-information project, not the official City of Palmdale website. Stable reference: corpuslaw.us/code/1c0d883c-72f1-4e09-8958-d5ee5f6ec900

§ 8.04.756: Amendments to Chapter 6 of the Palmdale Residential Code.

Chapter 6, Wall Construction, of the Palmdale Residential Code as adopted by incorporation of the California Residential Code is hereby modified as follows: Lines 20, 21, 24, and 34 through 37 of Table R602.3(1) of the 2025 Edition of the California Residential Code are amended to read as follows: TABLE R602.3(1)—continued FASTENING SCHEDULE ITEM | DESCRIPTION OF BUILDING ELEMENTS | NUMBER AND TYPE OF FASTENERa, b, c | SPACING AND LOCATION 20 k | 1" × 6" sheathing to each bearing | 3-8d box (2½" × 0.113"); or2-8d common (2½" × 0.131"); or 2-10d box (3" × 0.128"); or2 staples, 1" crown, 16 ga., 1¾" long | Face nail 21 k | 1" × 8" and wider sheathing to each bearing | 3-8d box (2½" × 0.113"); or3-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or3 staples, 1" crown, 16 ga., 1¾" long | Face nail Wider than 1" × 8"4-8d box (2½" × 0.113"); or3-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or4 staples, 1" crown, 16 ga., 1¾" long Floor 24 k | 1" × 6" subfloor or less to each joist | 3-8d box (2½" × 0.113"); or2-8d common (2½" × 0.131"); or 3-10d box (3" × 0.128"); or2 staples, 1" crown, 16 ga., 1¾" long | Face nail Other wall sheathing 34 k | 1/2" structural cellulosic fiberboard sheathing | 1½" x 0.120" galvanized roofing nail, 7/16" head diameter, or 1¼" long 16 ga. staple with 7/16" or 1" crown | 3 | 6 35 k | 25/32" structural cellulosic fiberboard sheathing | 1¾" x 0.120" galvanized roofing nail, 7/16" head diameter, or 1¼" long 16 ga. Staple with 7/16" or 1" crown | 3 | 6 36 k | 1/2" gypsum sheathingd | 1½" x 0.120" galvanized roofing nail, 7/16" head diameter, or 1¼" long, 16 ga.;staple galvanized, 1½" long; 7/16" or 1" crown or 1¼" screws, Type W or S | 7 | 7 37 k | 5/8" gypsum sheathingd | 1¾" galvanized roofing nail, 7/16" head diameter, or 1¼" long, 16 ga.;staple galvanized, 1½" long; 7/16" or 1" crown or 1¼" screws, Type W or S | 7 | 7 k. Use of staples in roof, floor, and braced wall panels shall be prohibited in Seismic Design Category D0, D1, or D2. Footnote "b" of Table R602.3(2) of the 2025 Edition of the California Residential Code is amended to read as follows: b. Staples shall have a minimum crown width of 7/16-inch on diameter except as noted. Use of staples in roof, floor, subfloor, and braced wall panels shall be prohibited in Seismic Design Category D0, D1, or D2. Table R602.10.3(3) of the 2025 Edition of the California Residential Code is amended to read as follows: [image] a. Linear interpolation shall be permitted. b. Interpolation of bracing length between the Sds values associated with the seismic design categories shall be permitted when a site-specific Sds value is determined in accordance with Section 1613.2 of the California Building Code. c. Where the braced wall line length is greater than 50 feet, braced wall lines shall be permitted to be divided into shorter segments having lengths of 50 feet or less, and the amount of bracing within each segment shall be in accordance with this table. d. Method LIB shall have gypsum board fastened to not less than one side with nails or screws in accordance with Table R602.3(1) for exterior sheathing or Table R702.3.5 for interior gypsum board. Spacing of fasteners at panel edges shall not exceed 8 inches. e. Methods PFG and CS-SFB do not apply in Seismic Design Categories D0, D1, and D2. f. Methods PFH, PFG and ABW are only permitted on a single story or a first of two stories. g. Where more than one bracing method is used, mixing methods shall be in accordance with Section R602.10.4.1. h. One- and two- family dwellings in Seismic Design Category D2 exceeding two stories shall be designed in accordance with accepted engineering practice. i. Methods GB and PCP braced wall panel h/w ratio shall not exceed 1:1 in SDC D0, D1, and D2. Methods DWB, SFB, PBS, HPS, and CS-SFB are not permitted in D0, D1 and D2. Table R602.10.4 of the 2025 Edition of the California Residential Code is amended to read as follows: [image] [image] a. Adhesive attachment of wall sheathing, including Method GB, shall not be permitted in Seismic Design Categories C, D0, D1 and D2. b. Applies to panels next to garage door opening where supporting gable end wall or roof load only. Shall only be used on one wall of the garage. In Seismic Design Categories D0, D1, and D2, roof covering dead load shall not exceed 3 psf. c. Garage openings adjacent to a Method CS-G panel shall be provided with a header in accordance with Table R602.7(1). A full-height clear opening shall not be permitted adjacent to a Method CS-G panel. d. Method CS-SFB does not apply in Seismic Design Categories D0, D1, and D2. e. Method applies to detached one- and two- family dwellings in Seismic Design Categories D0 through D2 only. f. Methods GB and PCP braced wall panel h/w ratio shall not exceed 1:1 in SDC D0, D1, and D2. Methods LIB, DWB, SFB, PBS, HPS, and PFG are not permitted in SDC D0, D1, and D2. g. Use of staples in braced wall panels shall be prohibited in SDC D0, D1, and D2. Figure R602.10.6.1 of the 2025 Edition of the California Residential Code is amended to read as follows: [image] Figure R602.10.6.2 of the 2025 Edition of the California Residential Code is amended to read as follows: [image] Figure R602.10.6.4 of the 2025 Edition of the California Residential Code is amended to read as follows: [image] Section R803.2.4 is added to Chapter 8 of the 2025 Edition of the California Residential Code to read as follows: R803.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms shall conform with Section R503.2.4.

( Ord. 1595 § 1 (Exh. A), 2022 ; Ord. 1661 , 10/21/2025 )

Ask a question about Palmdale law

Corpus searches the Palmdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.