§ 81.2.30: Expansive soils. [Geological]

Section 1809.16 is added to the 2025 California Building Code to read as follows: 1809.16 Expansive Soils. When expansive soils are present, the Building Official shall require that footings supporting light-frame construction shall, at a minimum, comply with the following provisions: 1. MINIMUM FOUNDATION REQUIREMENTS FOR BEARING WALLS LOCATED IN EXPANSIVE SOIL Number of Stories | Thickness of Wall Foundation (Inches) | Pier(inches) | Width of Footing(Inches) | Thickness of Footing(Inches) | Depth of Foundation Below Natural Grade Int./Ext.(Inches) Concrete | Unit Masonry 1 | 8 | 8 | 16x16 | 15 | 8 | 18/24 2 | 8 | 8 | - | 18 | 8 | 18/24 3 | 10 | 10 | - | 24 | 10 | 18/24 2. MINIMUM FOOTINGS AND FOUNDATION WALL REQUIREMENTS Footings and foundation walls when located on expansive soil shall be of concrete poured integrally and continuous under all exterior and interior bearing walls. Footings and foundation walls shall be reinforced continuously top and bottom. Footings and foundation walls for one-story buildings shall have a minimum of two (2) one-half (½) inch diameter steel bar. Footings and foundation walls for two story and three story buildings and over shall have a minimum of two (2) five-eighths (⅝) inch diameter steel bars. All access openings through foundation walls shall be provided with additional concrete and steel below access openings. Crawl holes through interior foundation walls shall not be closer than ten (10) feet to any intersecting exterior wall. Footings below any such crawl hole shall be dropped to provide a reinforced concrete beam section with a depth of at least twelve (12) inches between reinforcing rods. Foundation walls supporting wood shall extend six (6) inches above the finish grade adjacent to the wall at all points. 3. MINIMUM SLAB FLOOR REQUIREMENTS Concrete slab floors shall be a minimum of four (4) inches thick reinforced with one-half (½) inch diameter steel bars @ sixteen (16) inches on center in each direction. Concrete to be underlain by two (2) layers of two (2) inch sand fill with six (6) mils thick moisture barrier membrane between the two layers. Subgrade shall be saturated to 18” depth prior to placement of concrete.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.