§ 81.2.39 — Wood-frame diaphragms. [Geological]
Municipal Code, City of Torrance, California · Torrance Municipal Code § 81.2.39
Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/f199426f-489c-4850-9e14-a5da2808682e
§ 81.2.39: Wood-frame diaphragms. [Geological]
Section 2306.2 of the 2025 Edition of the California Building Code is amended to read as follows: 2306.2 Wood-frame diaphragms. Wood-frame diaphragms shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.2(1) or 2306.2(2) shall only be permitted for structures assigned to Seismic Design Category A, B, or C. Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official. The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for wind design. Wood structural panels used to resist seismic diaphragm forces in structures assigned to Seismic Design Category D, E or F shall be applied directly to the framing members. Exception: Wood structural panels are permitted to be fastened over solid lumber planking or laminated decking, provided the panel joints and lumber planking or laminated decking joints do not coincide.
Ask a question about Torrance law
Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.