§ 81.2.36 — Quality of nails. [Geological]

Municipal Code, City of Torrance, California · Torrance Municipal Code § 81.2.36

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/d74cabc7-bee7-454c-a409-f9b475f96711

§ 81.2.36: Quality of nails. [Geological]

Section 2304.10.3.1 is added to Chapter 23 of the 2025 Edition of the California Building Code to read as follows: 2304.10.3.1 Quality of nails. In Seismic Design Category D, E or F, mechanically driven nails used in wood structural panel shear walls shall meet the same dimensions as that required for hand-driven nails, including diameter, minimum penetration and minimum head diameter. Clipped head or box nails are not permitted in new construction. The allowable design value for clipped head nails in existing construction shall be multiplied by the nail-head-area ratio of clipped head nails to that of the same size hand-driven nails.