§ 811.1.10 — Information required on plans

Municipal Code, City of Torrance, California · Torrance Municipal Code § 811.1.10

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/65de07a8-4666-43de-9aec-139f8f22a9e6

§ 811.1.10: Information required on plans.

a) General. In addition to the seismic analysis required elsewhere in this chapter, the licensed engineer or architect responsible for the seismic analysis of the building shall determine and record the information required by this section on the approved plans. b) Construction Details. The following requirements with appropriate construction details shall be made part of the approved plans: 1) All unreinforced masonry walls shall be anchored at the roof level by tension bolts through the wall as specified in Table No. I or by approved equipment at a maximum anchor spacing of six (6) feet. Anchors installed in accordance with Section 2310 of the Uniform Building Code shall be accepted as conforming to this requirement. All unreinforced masonry walls shall be anchored at all floors with tension bolts through the wall or by existing rod anchors at a maximum anchor spacing of six (6) feet. All existing rod anchors shall be secured to the joists to develop the required forces. The city may require testing to verify the adequacy of the embedded ends of existing rod anchors. Tests when required shall conform to Subsection 811.1.9(h). When access to the exterior face of the masonry wall is prevented by proximity of an existing building, wall anchors conforming to items and 6 in Table No. 11-I below may be used. Alternate devices to be used in lieu of tension bolts for masonry wall anchorage shall be tested as specified in Subsection 811.1.9(i). 2) Diaphragm chord stresses of horizontal diaphragms shall be developed in existing materials or by addition of new materials. 3) Where trusses and beams other than rafters or joists are supported on masonry, ledges or columns shall be installed to support vertical loads of the roof or floor members. 4) Parapets and exterior wall appendages not capable of resisting the forces specified in this chapter shall be removed, stabilized or braced to ensure that the parapets and appendages remain in their original position. 5) All deteriorated mortar joints in unreinforced masonry walls shall be pointed with Type S or N mortar. Prior to any pointing, the wall surface must be raked and cleaned to remove loose and deteriorated mortar. All preparation and pointing shall be done under the continuous inspection of a registered deputy building inspector certified to inspect masonry or concrete. At the conclusion of the project, the inspector shall submit a written report to the city setting forth the portion of work inspected. 6) Repair details of any cracked or damaged unreinforced masonry wall required to resist forces specified in this chapter. c) Existing Construction. The following existing construction information shall be made part of the approved plans: 1) The type and dimensions of existing walls and the size and spacing of floor and roof members. 2) The extent and type of existing wall anchorage to floors and roof. 3) The extent and type of parapet corrections which were performed in accordance with Section 2310 of the Uniform Building Code. 4) Accurately dimensioned floor plans and masonry wall elevations showing dimensioned openings, piers, wall thickness and heights. 5) The location of cracks or damaged portions of unreinforced masonry walls requiring repairs. 6) The type of interior wall surfaces and if reinstalling or anchoring of ceiling plaster is necessary. 7) The general condition of the mortar joints and if the joints need pointing. TABLE NO. 11-A RATING CLASSIFICATIONS Type of Building | Classification Essential building | I High-risk building | II Medium-risk building | III Low-risk building | IV TABLE NO. 11-B TIME LIMITS FOR COMPLIANCE Required Action by Owner | Complete Building Permit Within | Commence Construction Within | Complete Construction Within Complete structural alteration or building demolition | 14 months | 180 days* | 3 years Wall anchor installation | 180 days | 270 days | 1 year * Measured from date of building permit issuance. TABLE NO. 11-C SERVICE PRIORITIES AND EXTENDED TIME PROVISIONS Rating Classification | Occupant Load | Extension of Time if Wall Anchors Are Installed | Minimum Time Period for Service of Order I (Highest Priority) | Any | 1 year | 0 II | 100 or more | 1 year | 90 days III | 100 or more | 1 year | 1 year More than 50 but less than 100 | 1 year | 2 years More than 19 but less than 51 | 1 year | 3 years IV (Lowest Priority) | Less than 20 | 1 year | 4 years TABLE NO. 11-D HORIZONTAL FORCE FACTORS BASED ON RATING CLASSIFICATION Rating Classification | IKCS I | 0.186 II | 0.133 III & IV | 0.100 TABLE NO. 11-E HORIZONTAL FORCE FACTORS "IS" FOR PARTS OR PORTIONS OF STRUCTURES Rating Classification | IS I | 1.50 II | 1.00 III & IV | 0.75 TABLE NO. 11-F HORIZONTAL FORCE FACTOR "Cp" FOR PARTS OR PORTIONS OF BUILDINGS OR OTHER STRUCTURES-(1) Parts or Portion of Buildings | Direction of Force | Value of Cp Exterior bearing and nonbearing walls; interior bearing walls and partitions interior nonbearing walls and partitions over ten (10) feet in height; masonry fences over six (6) feet in height | Normal to flat surface | 0.20 Cantilever parapet and other cantilever walls, except retaining walls | Normal to flat surface | 1.00 Exterior and interior ornamentations and appendages | Any direction | 1.00 When connected to or part of a building; towers, tanks, towers and tanks plus contents, racks over eight (8) feet three (3) inches in height plus contents, chimneys, smokestacks and penthouses | Any direction | 0.202,4 When connected to or part of a building; rigid and rigidly mounted equipment and machinery are required for continued operation of essential occupancies5 | Any horizontal direction | 0.203 Tanks plus effective contents resting on the ground | Any direction | 0.12 Floors and roofs acting as diaphragms | In the plane of the diaphragm | 0.126 Prefabricated structural elements, other than walls with force applied at center of gravity of assembly | Any horizontal direction | 0.30 Connections for exterior panels or elements | Any direction | 2.00 Notes: 1See Subsection 811.1.8(b) for use of Cp. 2When located in the upper portion of any building with any h/D ratio of five (5) to one (1) or greater, the value shall be increased by fifty (50) percent. 3For flexible and flexibly mounted equipment and machinery, the appropriate values for Cp shall be determined with consideration given to both the dynamic properties of the equipment and machinery and to the building or structure in which it is placed. 4The Wp for storage racks shall be the weight of the racks plus contents. The value of Cp for racks over two (2) storage support levels in height shall be 0.16 for the levels below the top two (2) levels. 5The design of the equipment and machinery and their anchorage is an integral part of the design and specification of such equipment or machinery. The structure to which the equipment or machinery is mounted shall be capable of resisting the anchorage forces (see also Subsection 2312(k) of the Uniform Building Code). 6Floor and roofs acting as diaphragms shall be designed for a minimum force resulting from a Cp of .12 applied to Wp unless a greater force results from the distribution of lateral forces in accordance with Subsection 2312(e) of the Uniform Building Code. TABLE NO. 11-G ALLOWABLE VALUE OF HEIGHT-THICKNESS RATIO OF UNREINFORCED MASONRY WALLS WITH MINIMUM QUALITY MORTAR1,2 Buildings with Crosswalks as Defined by Section 811.1.3 | All Other Buildings Walls of one (1) story buildings | 16 | 13 First-story wall of multi-story buildings | 16 | 15 Walls to top story of multi-story buildings | 14 | 9 All other walls | 16 | 13 1Minimum quality mortar shall be determined by laboratory testing in accordance with Subsection 811.1.9(c). 2Table No. 11-G is not applicable to buildings of Rating Classification I. Walls of buildings within Rating Classification I shall be analyzed in accordance with Subsection 911.1.8(f). TABLE NO. 11-H VALUES FOR EXISTING MATERIALS Existing Materials or Configuration of Materials | Allowable Values 1. | Horizontal Diaphragms a. | Roofs with straight sheathing and roofing applied directly to the sheathing | 100 pounds per foot for seismic shear b. | Roofs with diagonal sheathing and roofing applied directly to the sheathing | 400 pounds per foot for seismic shear c. | Floors with straight tongue-and-groove sheathing | 150 pounds per foot for seismic shear d. | Floors with straight sheathing and finished wood flooring | 300 pounds per foot for seismic shear e. | Floors with diagonal sheathing and finished wood flooring | 450 pounds per foot for seismic shear f. | Floors or roof with straight sheathing and plaster applied to the joist or rafters2 | Adds 50 pounds per foot to the allowable values for items 1(a) and 1(c) 2. | Shear walls Wood stud walls with lath and plaster | 100 pounds per foot each side for seismic shear 3. | Plain concrete footings | F = 1,500 psi unless otherwise shown by tests 4. | Douglas Fir Wood | Allowable stress same as No. 1 D.F.3 5. | Reinforcing Steel | f = 18,000 pounds per square inch maximum3 6. | Structural Steel | f = 20,000 pounds per square inch maximum3 1Material must be sound and in good condition 2The wood lath and plaster must be reattached to existing joists or rafters in a manner approved by the city. 3Stresses given may be increased for combinations of loads as specified in Subsection 811.1.8(g)2. TABLE NO. 11-I ALLOWABLE VALUES OF NEW MATERIALS USED IN CONNECTION WITH EXISTING CONSTRUCTION New Materials or Configuration of Materials1 | Allowable Values 1. | Horizontal Diaphragms Plywood sheathing applied directly over existing straight sheathing with ends of plywood sheets bearing on joists or rafters and edges of plywood located on center of individual sheathing boards | Same as specified in Table No. 25-J of the Uniform Building Code for blocked diaphragms 2. | Shear walls a. | Plywood sheathing applied directly over existing studs. No value shall be given to plywood applied over existing plaster or wood sheathing | Same as values specified in Table 25-K of the Uniform Building Code for shear walls. b. | Drywall or plaster applied directly over existing wood studs | 75 percent of the values specified in Table No. 47-I of the Uniform Building Code c. | Drywall or plaster applied to plywood sheathing over existing wood studs | 33⅓ percent of the values specified in Table No. 47-I of the Uniform Building Code 3. | Shear Bolts. Shear bolts and shear dowels embedded a minimum of eight (8) inches into unreinforced masonry walls. Bolt centered on a two and one-half (2-½) inch diameter hole with dry pack or nonshrink grout around the circumference of bolt or dowel1,3 | 100 percent of the values for plain masonry specified in Table No. 24-G of the Uniform Building Code. No values larger than these given for threefourths (¾) inch bolts shall be used. 4. | TENSION BOLTS Tension bolts and tension dowels extending entirely through unreinforced masonry walls secured with bearing plates on far side of wall with at least thirty (30) square inches of area2,3 | 1,200 pounds per bolt or dowel 5. | WALL ANCHORS a. | Bolts extending to the exterior face of the wall with two and one-half (2-½) inch round plate under the head. Install as specified for shear bolts. Spaced not closer than twelve (12) inches on centers1,2,3 | 600 pounds per bolt b. | Bolts or dowels extending to the exterior face of the wall with a two and one-half (2-½) inch round plate under the head and drill at an angle of twenty-two and one-half (22-½) degrees to the horizontal. Installed as specified for shear bolts1,2,3 | 1,200 lbs per bolt or dowel 6. | INFILLED WALLS Reinforced masonry infilled openings in existing unreinforced masonry walls with keys or dowels to match reinforcing | Same as values specified for unreinforced masonry walls 7. | Reinforced Masonry Masonry piers and walls reinforced per Section 2418 of the Uniform Building Code | Same as values specified in Table No. 24-B of the Uniform Building Code 8. | Reinforced Concrete Concrete footings, walls and piers reinforced as specified in Chapter 26 and designed for tributary loads | Same as values specified in Chapter 26 of the Uniform Building Code 9. | Existing Foundation Loads Foundation loads for structures exhibiting no evidence of settlement | Calculated existing foundation loads due to maximum dead load plus live load may be increased twenty-five (25) percent for dead load, and may be increased fifty (50) percent for dead load plus seismic load required by this chapter. 1Bolts and dowels to be tested as specified in Subsection 811.1.9(f). 2Bolts and dowels to be one-half (½) inch minimum in diameter. 3Drilling for bolts and dowels shall be done with an electric rotary drill. Impact tools shall not be used for drilling holes or tightening anchor and shear bolt nuts. TABLE NO. 11-J ALLOWABLE SHEAR STRESS FOR TESTED UNREINFORCED MASONRY 80 Percent of Test Results in PSI Not Less Than | Average Test Results of Cores in PSI | Seismic in Plane Shear Based on Gross Area* 30 plus axial stress | 20 | 3 psi 40 plus axial stress | 27 | 7 psi 50 plus axial stress | 33 | 5 psi 100 plus axial stress or more | 67 or more | 10 psi maximum * | Allowable shear stress may be increased by addition of ten (10) percent of the axial stress due to the weight of the wall directly above.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.