For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 811.1.8 — Analysis and design

Municipal Code, City of Torrance, California · Torrance Municipal Code § 811.1.8

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/d7ed4196-49c8-40b9-8ae9-0c9670479c6e

§ 811.1.8: Analysis and design.

a) General. Every structure within the scope of this chapter shall be analyzed and constructed to resist minimum total lateral seismic forces assumed to act nonconcurrently in the direction of each of the main axis of the structure in accordance with the following equation: V = IKCSW | ......(811-1) The value of IKCS need exceed the values set forth in Table No. 11-D based on the applicable rating classification of the building. b) Lateral Forces on Elements and Structures. Parts or portions of structures shall be analyzed and designed for lateral loads in accordance with Subsection 811.1.8(a) and 2312(e) of the Uniform Building Code but not less than the value from the following equation: Fp = ICpSWp | ......(811-2) For the provisions of this subsection, the product of IS need not exceed the values as set forth in Table No. 11-E below. EXCEPTION: Unreinforced masonry walls in buildings and having a Rating Classification of one (1) may be analyzed in accordance with Section 811.1.9. The value of Cp need not exceed the values set forth in Table 11-F below. c) Anchorage and Interconnection. Anchorage and interconnection of all parts, portions and elements of the structure shall be analyzed and designed for lateral forces in accordance with Table No. 11-F below of this chapter and the equation Fp = ICpSWp as modified by Table No. 11-E below. Minimum anchorage of masonry walls to each floor or roof shall resist a minimum force of two hundred (200) pounds per linear foot acting normal to the wall at the level of the floor or roof. d) Level of Required Repair. Alteration and repairs required to meet the provisions of this chapter shall comply with all other applicable requirements of this code unless specifically provided for in this chapter. e) Required Analysis. 1) General. Except as modified herein, the analysis and design relating to the structural alteration of existing structures within the scope of this chapter shall be in accordance with the analysis specified in Division 23 of the Uniform Building Code, 198 Edition, or as it may be amended from time to time. 2) Continuous Stress Path. A complete, continuous stress path from every part or portion of the structure to the ground shall be provided for the required horizontal forces. 3) Position Connections. All parts, portions or elements of the structure shall be interconnected by positive means. f) Analysis Procedure. 1) General. Stresses in materials and existing construction utilized to transfer seismic forces from the ground to parts or portions of the structure shall conform to those permitted by the Uniform Building Code and those materials and types of construction specified in Section 811.1.9 EXCEPTION: The Building Official has the authority to accept alternate methods of retrofit in accordance with Section 81.2.1(h). 2) Connections. Materials and connections used for interconnection of parts and portions of the structure shall conform to the Uniform Building Code. Nails may be used as part of an approved connector. 3) Unreinforced Masonry Walls. Except as modified herein, unreinforced masonry walls shall be analyzed as specified in Sections 2416, 2417 and 2419 and to withstand all vertical loads as specified in Division 23 of the Uniform Building Code in addition to the seismic forces required by this chapter. The fifty (50) percent increase in the seismic force factor for shear walls as specified in Table No. 24-H below of the Uniform Building Code may be omitted in the computation of seismic loads to existing shear walls. No allowable tension stress will be permitted in unreinforced masonry walls. Walls not capable of resisting the required design forces specified in this chapter shall be strengthened or shall be removed and replaced. EXCEPTIONS: 1) | Unreinforced masonry walls in buildings not classified as a Rating Classification I pursuant to Table No. 11-A below may be analyzed in accordance with Section 811.1.9 2) | Unreinforced masonry walls which carry no design loads other than their own weight may be considered as veneer if they are adequately anchored to new supporting elements. g) Combination of Vertical and Seismic Forces. 1) New Materials. All new materials introduced into the structure to meet the requirements of this section which are subject to combined vertical and horizontal forces shall comply with Subsection 2303(f) of the Uniform Building Code. 2) Existing Materials. When stresses in existing lateral force-resisting elements are due to a combination of dead loads plus seismic loads, the allowable working stress specified in the Uniform Building Code may be increased one hundred (100) percent. However, no increase will be permitted in the stresses allowed in Section 811.1.9 and the stresses in members due only to seismic and dead loads shall not exceed the values permitted by Subsection 2303(d) of the Uniform Building Code. 3) Allowable reduction of bending stress by vertical load. In calculating tensile fiber stress due to seismic forces required by this chapter, the maximum tensile fiber stress may be reduced by the full direct stress due to vertical dead loads.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.