§ 811.1.7 — Historical buildings

Municipal Code, City of Torrance, California · Torrance Municipal Code § 811.1.7

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/d2d345b6-fa8f-4014-9c1e-5c146383a8f8

§ 811.1.7: Historical buildings.

a) General. The standards and procedures established by this chapter shall apply in all aspects to a historical building except that as a means to preserve original architectural elements and facilitate restoration, a historical building may, in addition, comply with the special provisions set forth in this section. b) Unburned Clay Masonry or Adobe. Existing or re-erected walls of adobe construction shall conform to the following: 1) Unreinforced adobe masonry walls shall not exceed a height or height-to-thickness ratio of five (5) for exterior bearing walls and must be provided with a reinforced bond beam at the top, interconnecting all walls. Minimum beam depth shall be six (6) inches and a minimum width of eight (8) inches less than the wall width. Minimum wall thickness shall be eighteen (18) inches for exterior bearing walls and ten (10) inches for adobe partitions. No adobe structure shall exceed one (1) story in height unless the historic evidence indicates a two-story height. In such cases the height-to-thickness ratio shall be the same as above for the first floor based on the total two-story height, and the second floor wall thickness shall not exceed the ratio five (5) by more than twenty (20) percent. Bond beams shall be provided at the roof and second floor levels. 2) Foundation footing shall be reinforced concrete under newly reconstructed walls and shall be fifty (50) percent wider than the wall above, soil conditions permitting, except that the foundation wall may be four (4) inches less in width than the wall above if a rock, burned brick, or stabilized adobe facing is necessary to provide authenticity. 3) New or existing unstabilized brick and adobe brick masonry shall have an average compressive strength of two hundred twenty-five (225) pounds per square inch when tested in accordance with ASTM designation C 67. One sample out of five (5) may have a compressive strength of not less than one hundred eighty-eight (188) pounds per square inch. Unstabilized brick may be used where existing bricks are unstabilized and where the building is not susceptible to flooding conditions or direct exposure. Adobe may be allowed a maximum value of three (3) pounds per square inch for shear with no increase for lateral forces. 4) Mortar may be of the same soil composition and stabilization as the brick in lieu of cement mortar. 5) Nominal tension stresses due to seismic forces normal to the wall may be neglected if the wall meets thickness requirements and shear values allowed by this subsection. c) Archaic Materials. Allowable stresses for archaic materials not specified in this code shall be based on substantiating research data or engineering judgment, subject to the department’s satisfaction. d) Alternative Materials and SHBC Advisory Review. Alternative materials, design or method of construction will be considered as set forth in Section 811.1.9. In addition, when a request for an alternative proposed design, material or method of construction is being considered, the city may file written request for opinion to the State Historical Building Code Advisory Board for its consideration, advice or findings in accordance with the SHBC.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.