For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14.21.140 — Drainage and terracing

Municipal Code of Lakewood, Colorado (Supp. No. 15: codified through Ordinance No. O-2026-16, adopted April 27, 2026) · Lakewood Municipal Code § 14.21.140

Corpus is an independent public-information project, not the official City of Lakewood website. Stable reference: corpuslaw.us/code/94f90ee7-96d9-453a-84ca-77f0add70d2f

14.21.140 - Drainage and terracing.

A. General. Unless otherwise indicated on the approved grading plan, drainage facilities and terracing shall conform to the provisions of this section for cut or fill slopes steeper than three horizontal to one vertical. B. Terrace. Terraces at least six feet in width shall be established at not more than 30-foot intervals on all cut or fill slopes to control surface drainage and debris except that where only one terrace is required, it shall be at mid-height. For cut or fill slopes greater than 60 feet and up to 120 feet in vertical height, one terrace at approximately mid-height shall be 12 feet in width. Terrace widths and spacing for cut and fill slopes greater than 120 feet in height shall be designed by the civil engineer and approved by the Director. Suitable access shall be provided to permit proper cleaning and maintenance. Swales or ditches on terraces shall have a minimum gradient of five percent and must be paved with reinforced concrete not less than four inches in thickness or with an approved equal paving. They shall have a minimum depth at the deepest point of one foot and a minimum paved width of five feet. A single run of swale or ditch shall not collect runoff from a tributary area exceeding 13,500 square feet (projected) without discharging into a down drain. C. Subsurface Drainage. Cut and fill slopes shall be provided with subsurface drainage as necessary for stability. D. Disposal. All drainage facilities shall be designed to carry waters to the nearest practicable drainage way approved by the Director and/or other appropriate jurisdiction as a safe place to deposit such waters. Erosion of ground in the area of discharge shall be prevented by installation of nonerosive downdrains or other acceptable devices. Building pads shall have a drainage gradient of two percent toward approved drainage facilities, unless waived by the Director. Exception: The gradient from the building pad may be one percent if all of the following conditions exist throughout the permit area: 1. No proposed fills are greater than ten feet in maximum depth. 2. No proposed finish cut or fill slope faces have a vertical height in excess of ten feet. 3. No existing slope, which has a slope face steeper than ten horizontally to one vertically, has a vertical height in excess of ten feet. E. Interceptor Drains. Paved interceptor drains shall be installed along the top of all cut slopes where the tributary drainage area above slopes towards the cut and has a drainage path greater than 40 feet measured horizontally. Interceptor drains shall be paved with a minimum of three inches of concrete or gunite and reinforced. They shall have a minimum depth of 12 inches and a minimum paved width of 30 inches measured horizontally across the drain. The slope of drain shall be approved by the Director.

(Ord. O-88-40 § 1 (part), 1988).

Ask a question about Lakewood law

Corpus searches the Lakewood sections it holds and shows the ones that match, with their citations. Free, no sign-in.