Sec. 14.32.150. - Service conditions.
A. Interference with quality of service. If, in the city's opinion, service to a customer creates interference with the quality of service supplied to neighboring customers, including those situations where the customer fails to comply with this chapter, the city may require the customer to provide, at the customer's own expense, such special or additional equipment as is required, or the city may provide such equipment if customer pays the net estimated installed cost of such equipment. If the customer refuses to provide its own corrective equipment, or to reimburse the city for the cost of such additional or special equipment as is required to eliminate interference with the quality of service to neighboring customers resulting from their operations, the city may refuse or discontinue the customer's service. B. Phase balancing. 1. Where three-wire single-phase, or three-wire three-phase, or four-wire combination single-phase and three-phase service is supplied, the load must be balanced as nearly as practicable between the two sides or several phases, respectively. In no case is the load on one side of a three-wire single-phase service to be greater than twice that on the other, nor the load on any one phase of a three-phase wye-connected service greater than twice that on any other phase. 2. In the event that the customer does not comply within 30 days with a request by the city to balance the service, the city will upgrade the facilities at the customer's expense to accommodate the imbalance. The repair of any damage to the city facilities caused by the imbalance will be at customer expense. C. Customer's wiring and equipment. 1. It shall be the customer's responsibility to provide suitable protective equipment such as fuses, circuit breakers and relays to adequately protect their equipment. If three-phase equipment is used, it shall be the customer's responsibility to protect it against phase failure, phase reversal, and under- and over-voltage. More specific requirements governing conditions of service are also contained in other regulations herein. 2. The customer's wiring shall be in accordance with applicable wiring codes. The city reserves the right to refuse or discontinue service to customer where customer's equipment or wiring is in hazardous conditions, or not in conformity with lawful codes and local regulations. All customers shall be solely responsible for the maintenance and safety of their wiring and equipment, and the city shall not in any way be liable for accident or damages occurring to the customers or to third parties because of contact with or failure of any portion of the customer's installation. D. Welders. 1. The city will serve, at the applicable rate and without additional compensation, welding equipment of the limited input type which conforms to the standards of NEMA, and which has a maximum input (primary) current rating not exceeding 12 amperes at 120 volts or 50 amperes at 208 or 240 volts. 2. Welding equipment which does not meet the standards of NEMA, or which exceeds in input rating of 12 amperes at 120 volts or 50 amperes at 208 or 240 volts, will also be served at the applicable rate, provided that service to such welders has no detrimental effect on service to neighboring customers. E. Motor protective devices. It is the customer's responsibility to ensure that all motor installations shall have protective apparatus or construction within the motor to accomplish equivalent protection as follows: 1. Motors that cannot be safely subjected to full-rated voltage at starting shall be provided with a device to ensure that on failure of voltage, such motors will be disconnected from the line. 2. Suitable overload and overcurrent running protection shall be provided for each motor so as to disconnect the motor from the line to protect it from damage caused by overheating. 3. Phase reversal and open-phase protection is recommended on all three-phase installations and is required for such installations involving elevators, hoists, and similar equipment to disconnect motors from the line in the event of phase reversal or opening of one phase. 4. In the event the above is not followed and damage to customer equipment occurs, the city will assume no responsibility. F. Motor starting limitations. Motors started at rated voltage require inrush currents generally six times greater than nominal, full-load currents. These high starting (locked rotor) currents create short duration voltage dips which can cause objectionable light flicker and operating problems with other equipment. The following motor starting limitations are established to maintain voltage levels within applicable industry standards. It is the customer's responsibility to comply with the following requirements: 1. Voltage drop standard. Motor starting currents, associated circuit voltage drops, and frequency of motor starts will comply with the most current version of IEEE Standard 1250. Voltage levels are to be calculated for the common connection point for the motor circuit with other devices, circuits, or services. 2. The customer should make certain that the customer's own electrical system is capable of handling the locked-rotor currents permitted without excessive voltage drop or other system effects. 3. Maximum permissible current values listed apply to an installation of a single motor. 4. Allowable locked rotor currents. a. Single-phase. i. Single-phase motorized equipment that is automatically controlled with frequent motor starts shall have locked-rotor currents not in excess of the following (the typical NEMA horse power rating is indicated for each current level): (a) 50 amperes at 120 volts: 1 hp. (b) 80 amperes at 208 volts: 3 hp. (c) 100 amperes at 240 volts: 4 hp. ii. Single-phase motorized equipment that is manually controlled with infrequent motor starts, and air conditioners, shall have locked-rotor currents not in excess of the following: (a) 100 amperes at 120 volts: 2 hp. (b) 160 amperes at 208 volts: 6 hp. (c) 200 amperes at 240 volts: 8 hp. iii. Motors having locked-rotor currents in excess of those allowed by subsections F.4.a.i and ii of this section may be permitted upon written approval of the city. b. Three-phase. i. Three-phase motors that are automatically controlled with frequent starts shall have maximum locked-rotor current not in excess of the following: (a) 780 amperes at 208 volts. (b) 340 amperes at 480 volts. (c) These values permit, in general, a 50 hp NEMA standard motor. ii. Three-phase motors with manual control and infrequent starts shall have maximum locked-rotor currents not in excess of the following: (a) 940 amperes at 208 volts: 60 hp (practical 208 V limit). (b) 680 amperes at 480 volts: 100 hp. iii. Three-phase motors, to be used where large loads or special conditions exist, may, upon written approval of LPC, have locked-rotor currents in excess of those allowed by subsections F.4.a and b of this section. 5. Motors having maximum locked-rotor currents exceeding those stated in subsections F.3 and 4 of this section may be operated if used in conjunction with devices designed to limit the starting currents to the above-specified maximum values. 6. Current-limiting devices may be omitted on the smaller motors of a group installation when their omission will not result in a starting current in excess of the allowable starting current of the largest motor of the group. G. Harmonics. 1. In the event that customer loads generate sufficient voltage and/or current harmonics to be detrimental to city equipment (such as transformers or meters) or to adversely affect other customer's loads, the customer will be required to take corrective action as determined by the city. Where the corrective action must be undertaken by the city, the customer will bear the expense of such corrective work. 2. In the event that the customer does not comply within 30 days after written notice from the city, the city may take corrective action at the customer's expense. The repair of any damage to city facilities will be at customer expense. H. Power factor. 1. All customers shall maintain a 95 percent power factor as measured at the Platte River Power Authority system monthly peak hour and day in the billing period. 2. All five horsepower or larger motors shall be required to install capacitors connected to the motor starter to be energized when the motor is running. 3. In the event that the customer does not correct the power factor within 30 days after written notice from the city, the city may take corrective action at the customer's expense. The repair of any damage to city facilities will be at customer expense. Additionally, any power factor penalty imposed by Platte River Power Authority on the city due to the customer not complying with subsection H.1 of this section may be passed on to the customer. I. Phase converters. 1. The city will serve, at the applicable rate, phase converting installations of the motor/generator type. These units generate balanced three-phase power from a single-phase input. 2. The single-phase motor unit is subject to all applicable sections of this chapter. 3. Capacitive or static converters will not be served. J. Compliance with applicable codes. All services, equipment and installations must meet all applicable codes and standards, including, but not limited to, the NEC, IEEE, ANSI, NEMA and NESC.
(Ord. No. O-2024-83, § 2, 12-17-2024)
Ask a question about Longmont law
Corpus searches the Longmont sections it holds and shows the ones that match, with their citations. Free, no sign-in.