For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.05.050 — Streets and vehicle access and circulation

Code of Ordinances of the City of Longmont, Colorado (Codified through Ordinance No. O-2026-39, enacted June 23, 2026 (Supp. No. 9)) · Longmont Code of Ordinances § 15.05.050

Corpus is an independent public-information project, not the official City of Longmont website. Stable reference: corpuslaw.us/code/7c2be150-e402-4dca-802c-6d2936b8a360

Sec. 15.05.050. - Streets and vehicle access and circulation.

A. Purpose. Within each development, the vehicle access and circulation system shall accommodate the safe, efficient, and convenient movement of vehicles, bicycles, pedestrians, and transit through the development and to and from adjacent properties and land uses. B. Applicability. This section shall apply to new development and redevelopment. C. Consistency required. The layout of streets and highways shall conform to the street classification and configuration designated in the comprehensive plan, with all adopted street transportation, and multi-use corridor plans, as addressed in the city standards, and with the provisions of this development code. D. Streets. 1. General design standards. a. General. The design of public streets shall reflect the nature and function of the street in relation to proposed and existing surrounding land uses. b. City standards. Design and construction of all public streets, including alleys, are addressed in the city standards. 2. Connectivity. a. For purposes of this section, the term "local street system" means the interconnected system of collector and local streets providing access to development from an arterial street. b. The local street system for a proposed development shall be designed to be safe, efficient, convenient, and attractive for multi-modal use, including, without limitation, cars, trucks, buses, bicycles, pedestrians and emergency vehicles. c. The local street system shall provide multiple direct connections to and between local destinations such as parks, schools, and shopping. Local streets shall provide for both intra- and inter-neighborhood connections to connect separate developments together, rather than forming barriers between them. The street configuration within each individual development shall contribute to the street system of the neighborhood. d. Where rights-of-way for arterial, collector, or local streets exist or are designated on property adjacent to a proposed development, and those rights-of-way extend to the property or boundary line of the proposed development, the proposed development shall dedicate rights-of-way to connect those adjacent rights-of-way into or through the land contained in the proposed development. e. New subdivisions shall be designed in a transportation grid layout to the maximum extent practicable. f. Gated developments are prohibited where access to a public street would be restricted. 3. Consideration of existing topography. Streets shall be designed to avoid steep grades and deep cuts given the existing topography. 4. New intersections and curb cuts. a. Intersections and curb cuts shall be designed to provide the greatest safety for both pedestrians and motorists. In addition, curb cuts for access to off-street parking areas shall comply with table 15.05.050. Table 15.05.050: Curb Cut Design Requirements District or Area | Minimum Width | Maximum Width Residential zoning districts [1] | 12 feet | 24 feet Mixed-use and nonresidential zoning districts (serving one principal use) | 12 feet | 30 feet Mixed-use and nonresidential zoning districts (serving more than one principal use) | 12 feet | 40 feet Notes: [1] Driveways serving detached or recessed garages for single- or two-family dwellings shall be a minimum of 10 feet wide. b. For lots with 100 feet or less of street frontage, no more than one curb cut per lot is allowed. A maximum of one curb cut for every 100 feet of local street frontage or portion thereof may be allowed for lots with frontage in excess of 100 feet. c. New curb cuts for direct access from lots onto regional and principal arterial streets are prohibited. 5. Private streets prohibited. Streets held in private ownership yet used as a public way for provision of public access and services, are prohibited. Private drives that provide access across a lot are allowed, provided that maintenance responsibilities are specified on a plat or plan. 6. Cul-de-sacs. Cul-de-sacs shall comply with the following standards: a. Length. The maximum length of a cul-de-sac shall be 250 feet, measured from the center of the intersection to the center of the turnaround. b. Pedestrian and bicycle connections. Cul-de-sacs shall be designed to provide pedestrian ways and bicycle access routes at the bulb-end of the cul-de-sac to connect the cul-de-sac to an appropriate street to provide pedestrian/bicyclist circulation and access unless the decision-making body approves an alternative pedestrian access plan with the subdivision that provides adequate access. 7. No-outlet (dead-end) streets. Except for cul-de-sacs, as provided in this section, no-outlet streets are prohibited except in cases where such streets are designed to connect with future streets on adjacent land with a temporary turnaround easement at the end of the street as addressed in the city standards. 8. Alleys. Alleys shall be used to the maximum extent practicable for residential or mixed-use development subject to the following standards: a. Alleys shall connect through the block to a publicly dedicated street on each end; and b. Developments providing alleys may reduce lot area and width and front setback requirements of the applicable residential zoning district as noted in chapter 15.03, provided that all other standards of this development code are met. 9. Utilities. All plans for street and alley development shall contain all utility access, easement, service, and utility cabinet locations. Utility service cabinets should be located in the least visible and least intrusive locations possible. E. Block length. 1. Blocks shall not exceed 1,320 feet (one-quarter mile) in length between intersections, except where topography or other constraints or requirements dictate longer blocks. 2. Blocks in mixed-use zoning districts shall not exceed 660 feet (one-eighth mile) in length between intersections, except where topography or other constraints or requirements dictate longer blocks. 3. Blocks that exceed 660 feet in length shall provide a pedestrian and bicyclist access route through the center of the block. All such access routes shall meet the requirements stated in subsection G of this section. F. Traffic calming. Local and collector streets in residential and mixed-use districts shall be designed with traffic calming improvements, such as medians, pedestrian crossings, curb extensions, and other traffic calming techniques to reduce vehicle speeds and provide safe use of streets for all modes of transportation. Additional standards are addressed in the city standards section 200. G. Vehicle access and circulation. 1. Access design; general. Vehicle access to any property shall be controlled to protect the traffic-carrying capacity of the abutting street. Vehicle access shall generally be directed to lower volume streets first, and then to higher volume streets. 2. Access to public streets; general. a. Required. All new lots shall have access to a public street conforming to the standards stated in this section. In addition to direct access to a public street, access may be provided through techniques described in subsection G.6 of this section. b. Limits on access to streets. i. New direct access from a lot to an arterial street is prohibited. ii. New direct driveway access from a residential lot to a collector street is prohibited. iii. The city standards address additional access restrictions and requirements. c. Fire and emergency access. All development shall provide fire and emergency vehicle access according to applicable requirements stated in the fire code as adopted by the city. d. Location of access to public streets. i. In new multifamily and nonresidential developments, vehicular access shall be spaced at least 50 feet from the nearest right-of-way line of any intersecting street and no closer than 25 feet to any adjacent property line. However, either or both of these setback requirements may be reduced or enlarged to permit a single vehicular access point that can serve two adjacent properties or where compliance with these requirements would deny vehicular access to a property. ii. In addition, where it is not practical to meet these requirements, the director and general manager may approve a modification based on submittal of an acceptable alternative circulation plan, giving consideration to overall traffic movement and volume. In no case, however, shall the city deny access to a public right-of-way, unless the proposed access shall create an undue hazard to the public or unless other access alternatives exist. 3. Two means of access required. a. General rule. To ensure public safety and to provide an efficient transportation system, each new development or subdivision shall provide a minimum of two principal means of access to the development or subdivision from public streets. The two means of access shall separately connect to the public street system. b. Exceptions. i. This requirement may be waived by the general manager if the acreage or the number of lots is so limited, or if the configuration of the proposed development or subdivision is of such unusual shape that the proposed project cannot reasonably be served by more than a single street, and that single street shall meet the public safety and transportation needs of the subdivision. ii. Where the general manager finds that it is impractical to make a second principal street connection or that a second principal street connection is not necessary, a secondary emergency access connection shall be required when the number of units and the nature of the development dictate the emergency access. The general manager shall determine the size and construction of the emergency access connection based on the need to accommodate required emergency vehicles as determined by the fire marshal. c. Timing of required access provision. i. Where the development is to be constructed in phases, the phasing shall be established so that two principal means of access are constructed in conjunction with the initial phase of the development. Where the acreage or the number of lots in the initial phase of the development is so limited as to not create a major safety or transportation concern to the city, and when approved by the general manager and the fire marshal, the second principal means of access may be deferred until a subsequent phase. ii. When this is permitted, the city may require the applicant to post financial security up to 150 percent of the cost of construction of the second principal access according to the requirements of section 15.02.110 may limit the number of building permits issued to guarantee construction of the second principal access when it is needed, and may require the dedication of any right-of-way required to construct the second principal access. The general manager shall determine what method shall be required depending on the specific and unique circumstances of the development. 4. Reserve strips. Reserve strips controlling access to streets or for other purposes are prohibited unless such reserve strip is required and controlled by the city. 5. Access roads. The general manager may require access roads where a development or subdivision adjoins or contains an existing or proposed arterial street on which traffic volumes and vehicular speeds warrant special safety considerations. 6. Auto courts. Auto courts will be considered on a case-by-case basis as an alternative subdivision design under the standards described below. Auto courts should be limited to areas where parcel configurations may not allow for adequate street frontage. The use of auto courts should also be limited to minimize the impact on city services and utilities and on maintenance responsibilities of homeowners' and property owners' associations. Up to four one-family dwelling units may share a single driveway access to a public street through the use of an auto court layout approved through the preliminary subdivision plat review process described in section 15.02.060.E, provided that the auto court complies with the following standards: a. The surface of the shared driveway in the auto court shall be at least 20 feet wide and shall be surfaced with concrete or other permeable paving approved by the decision-making body (figure 5.1). b. Individual driveways leading from the shared driveway to each dwelling unit shall be at least 20 feet long, as measured from the front of the garage or carport to the closest edge of the shared driveway (figure 5.1). c. No portion of the shared driveway shall extend more than 150 feet from the closest edge of the adjacent public street to which the shared driveway gives access (figure 5.1). d. The design of the auto court shall permit a passenger vehicle to back out of an individual driveway and turn 90 degrees in either direction using only the individual driveway (but not individual driveways of any other residence), the shared driveway, or the adjacent public street. The American Association of State Highway and Transportation Officials (AASHTO) turning template for a "P" (passenger) design vehicle shall be used to confirm that these standards are met. e. The auto court design shall comply with all off-street parking requirements applicable to one-family dwellings. In addition, each auto court design shall provide one-half additional off-street parking space per dwelling unit, in a location other than a private driveway or on the shared driveway. f. Maintenance and repair of auto courts shall be the responsibility of a property owners' association or adjacent property owners. The city shall approve provisions for maintenance and repair during the subdivision review process. g. No parking shall be allowed on the shared driveway. h. The auto court shall not take access on a cul-de-sac bulb. i. The auto court access shall be from a standard-width street and the applicant shall demonstrate that there is adequate guest parking available on the street. j. Each dwelling on an auto court shall have at a minimum a two-car garage. k. The auto court shall comply with all other standards including fire and emergency access, and utility provision. Figure 5.1: Auto Courts [image omitted; see the official code]

(Code 2009, § 15.05.050)

Ask a question about Longmont law

Corpus searches the Longmont sections it holds and shows the ones that match, with their citations. Free, no sign-in.