For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.05.130 — Outdoor service, storage, equipment, loading and display

Code of Ordinances of the City of Longmont, Colorado (Codified through Ordinance No. O-2026-39, enacted June 23, 2026 (Supp. No. 9)) · Longmont Code of Ordinances § 15.05.130

Corpus is an independent public-information project, not the official City of Longmont website. Stable reference: corpuslaw.us/code/133a004b-0aad-4e95-aab3-f737c118bf1f

Sec. 15.05.130. - Outdoor service, storage, equipment, loading and display.

A. Outdoor service, storage and loading areas. 1. General design standards. a. In all developments loading docks, truck parking, outdoor storage, utility meters, HVAC and other mechanical equipment, trash collection, recycling collection, trash compaction, and other service functions shall be incorporated into the overall design theme of the building and the landscape so that the architectural design is continuous and uninterrupted by ladders, towers, fences, and equipment. b. These areas shall be located and screened so that the visual and acoustic impacts of these functions are fully contained and out of view from adjacent properties and public rights-of-way. Screening materials shall be similar to and of the same quality as the principal materials of the primary buildings and landscape. c. Screening, which may include walls, fencing, berming and landscaping, shall be an adequate height as demonstrated visually by the applicant. When plants are used for screening, as appropriate, they shall be planted and maintained to provide a solid screen within two years from the time of planting. 2. Trash/recycling/compost collection areas. The following regulations shall apply to all development except for one-family and two-family dwellings: a. Each lot or tract containing a principal structure shall provide a designated area with equal space for the placement of trash, recycling, and compost collection containers that shall be located and designed to ensure adequate space on-site for the maneuvering of collection vehicles. Each such area shall be incorporated into the overall design of the principal structure on the site, and shall be located in the rear or side of the lot to screen the storage area and separate it from residential uses to the maximum extent practicable. b. Trash, recycling, and compost collection areas shall not be located within any required buffer, between a principal building and any street (excluding alleys), or adjacent to a public pedestrian path, unless the decision-making body determines that the proposed location is appropriate and will not create an adverse impact on surrounding properties or neighborhoods. c. Trash, recycling, and compost collection areas that are visible to surrounding uses, properties, or rights-of-way shall include enclosures and gates of sufficient height to provide adequate screening. The enclosure shall be constructed of the same materials as used in the principal structure and the gate shall be constructed of a durable and quality metal and painted a compatible color. The enclosure gate shall remain closed except when being accessed. 3. Outdoor storage areas. a. Outdoor storage areas shall be incorporated into the overall design of the principal structure or the site and shall be screened from view from all property lines by an opaque fence or wall of sufficient height to provide adequate screening. The fence or wall shall incorporate at least one of the predominant materials and one of the predominant colors used in the principal structure. b. If an outdoor storage area shall be covered, then the covering shall include at least one of the predominant exposed roofing colors on the principal structure. c. Stored items shall not project above the fence or wall used to screen such materials. d. No flammable or explosive liquids, solids, or gases shall be stored in bulk above ground if they exceed the currently adopted fire code requirements. Flammable liquids or gases in excess of 1,000 gallons shall be stored underground. High pressure gases or liquids whether flammable or inflammable shall be stored above ground and shall meet all applicable laws and regulations. 4. Utility/mechanical equipment. Mechanical or utility equipment shall be sited away from residential uses and shall be screened by a wall, fence, or landscaping that is adequate in height as demonstrated visually by the applicant. Fences and walls shall be of similar quality materials and color as the principal structure. Plant materials used for screening shall be planted and maintained to provide a solid screen within two years of installation. B. Roof-top utility/mechanical equipment. Mechanical or utility equipment on the roof of a building shall be screened from public view to the maximum extent practicable by locating equipment in the center of the roof or providing screening materials around the mechanical equipment. All screening materials shall be compatible with the principal structure in terms of design, materials and color. C. Outdoor retail display areas. Unless explicitly stated otherwise in an approved plan or temporary use permit, no outdoor retail display area shall be located in a required off-street parking area or landscape or buffer yard area.

(Code 2009, § 15.05.130)

Ask a question about Longmont law

Corpus searches the Longmont sections it holds and shows the ones that match, with their citations. Free, no sign-in.