§ 15.05.070 — Underdrains

Code of Ordinances of the City of Longmont, Colorado (Codified through Ordinance No. O-2026-39, enacted June 23, 2026 (Supp. No. 9)) · Longmont Code of Ordinances § 15.05.070

Corpus is an independent public-information project, not the official City of Longmont website. Stable reference: corpuslaw.us/code/c5c79dfa-930e-48d0-9bbb-716579dac254

Sec. 15.05.070. - Underdrains.

A. Purpose. This section provides requirements for underdrain systems which are installed to provide a safe method for conveying groundwater from around building foundations to a point of discharge. B. Building perimeter underdrains. 1. When required. A building perimeter underdrain shall be provided around all foundations that retain earth and enclose habitable spaces located below grade. 2. Design and plan approval. a. The building perimeter underdrain must comply with all applicable city, state, and federal regulations in place at the time of construction and shall be designed by a state-registered professional engineer. b. Plans for the building perimeter underdrain shall be reviewed and approved by the chief building official. Approval of the plans by the city does not relieve the professional engineer, applicant, or owner from the responsibility to construct and maintain a workable system. 3. Compliance and inspection. a. The professional engineer shall inspect and certify, in writing, to the chief building official that the building perimeter underdrain was built according to the city-approved building perimeter underdrain plan. b. The professional engineer shall certify that the building perimeter underdrain is properly connected to the area underdrain or underdrain collection system. c. The city shall not issue the certificate of occupancy until receipt of the professional engineer's certification and the building perimeter underdrain connection has been completed, inspected and approved by a public works and natural resources engineer or inspector. d. The city may issue a stop-work order to the builder if connection of the building perimeter underdrain to the area underdrain or underdrain collection system is not completed, or if a sump pump is installed without prior written approval from the city. e. All building perimeter underdrains shall have a positive gravity outlet piped to an approved underdrain collection system, to a storm sewer, or to a drainage channel. The use of any conveyance system other than a gravity building perimeter underdrain system, including, but not limited to, sump pumps, must be approved in writing prior to installation by the general manager. f. Sump pits and pumps may be installed as a backup in addition to the gravity connection and must be approved in writing prior to installation by the general manager. g. No person shall make connections of sources of surface runoff to a building perimeter underdrain which in turn is connected directly or indirectly to an area underdrain and underdrain collection system. No person shall contribute or cause to be contributed, directly or indirectly, any pollutant or wastewater to the building perimeter underdrain. 4. Ownership and maintenance. The owner of the building, dwelling, or structure shall own and maintain its building perimeter underdrain and all other portions of the underdrain that are not a part of the area underdrain and underdrain collection system. C. Area underdrains and underdrain collection systems. 1. Design and plan approval. a. The area underdrain or underdrain collection system must comply with all applicable city, state and federal regulations in place at the time of construction. b. A professional engineer registered in the state must design, and stamp the area underdrain plans, underdrain collection system plans, and underdrain report. The system shall be designed in consideration of seasonal high groundwater levels anticipated at the project site. c. All area underdrains and underdrain collection systems shall have a positive gravity outlet piped to an approved underdrain collection system, to a storm sewer, or to a drainage channel. The use of any conveyance system other than a gravity system, such as a lift station, must be approved in writing prior to installation by the general manager. d. Area underdrains and underdrain collection systems, six inches in diameter or smaller, placed adjacent to and in the same trench as sanitary sewer mains shall be rigid walled nonperforated pipe and shall have a minimum clearance of one foot from the side of the underdrain pipe to the side of the sanitary sewer main pipe. Access points on underdrain systems are not allowed to connect to or surface into sanitary sewer manholes. e. Area underdrains and underdrain collection systems, six inches in diameter or larger must be placed in a separate trench from all other underground utilities. Area underdrains and underdrain collection system placed in the right-of-way shall be rigid walled nonperforated pipe. f. An underdrain report must be submitted with the plans, and shall, at a minimum, include the sizing criteria for the area underdrain and underdrain collection system and maintenance requirements. g. The city development review committee shall review the stamped plans and underdrain report. Approval of the plans and underdrain report by the city does not relieve the professional engineer, applicant, or owner from the responsibility to construct and maintain a workable system. 2. Compliance and inspection. a. The professional engineer shall perform regular inspections of the construction of the area underdrain and underdrain collection system to ensure that the system is built in accordance with the approved plans. b. As-built plans must conform to the city standards. Inspection of the area underdrain and underdrain collection system will also be performed by the public works and natural resources engineer or inspector. c. The city shall not issue any building permits for the premises served by the area underdrain or underdrain collection system until receipt of the professional engineer's inspection reports, dye testing and/or video inspection, and as-built plans. d. Access points shall be installed on area underdrains and underdrain collection systems. e. Copies of inspection reports will be provided to the city. Dye testing and video inspection of the area underdrain and underdrain collection system to ensure operability will be submitted with the inspection reports. f. No person shall make connections of sources of surface runoff to an area underdrain or underdrain collection system. No person shall contribute or cause to be contributed, directly or indirectly, any pollutant or wastewater to the area underdrain or underdrain collection system. g. No connection of one area underdrain and underdrain collection system to another will be allowed without the express written approval of the owner. 3. Ownership and maintenance. a. The property owners' association shall own and maintain any area underdrain or underdrain collection system if the system serves more than one property. Covenants, approved by the city, must specify ownership and ensure adequate maintenance by a property owners' association. b. Copies of the underdrain report, the professional engineer's inspection reports, the video inspection, and as-built plans will be provided to the property owners' association by the developer. c. Where practicable, installation of the area underdrain and underdrain collection system shall be on private property with the approval of the property owner. The city may allow installation of the area underdrain and underdrain collection system within common areas or on-site pedestrian trail systems. 4. Use of right-of-way. The city may approve installation of the area underdrain and underdrain collection system in public rights-of-way, public open space or public pedestrian trail systems, subject to the following: a. The applicant obtains an infrastructure permit and maintains infrastructure according to city standards and regulations; and b. The applicant indemnifies the city for all costs of repair (including repair of public areas, streets, landscaping, and utilities) and liability for failure of the system, as approved by the city attorney and the risk manager. D. Exceptions. 1. Submittal of exception request. Requests for exceptions to this section shall be submitted in writing to the general manager. The request shall state the exception requested, the justification and supporting data for the exception. The city may require that exceptions be signed by a professional engineer registered to do work in the state and bear their seal. 2. Criteria. a. Special circumstances or conditions exist which limit the ability of the design to meet the requirements outlined in this development code. Financial difficulties, loss of prospective profits and previously approved exceptions in other developments shall not be considered as special circumstances; or b. The exception represents an alternative design that will meet the intent of the requirements set forth in the code; c. In either case, if granted, the exception will not be detrimental to the public interest or other property and will not endanger the public safety, health or welfare. 3. Timing. All exceptions must be reviewed and acted on prior to construction. The city shall respond promptly in writing to such requests, but reserves a minimum of five working days for review and response. When additional time is required, the city shall notify the submitter of the need for additional time within two working days of the submittal. 4. Exception does not apply to other standards beyond the request. Approval of plans by the city, which contain design elements not in compliance with this development code, and for which an exception request has not been specifically requested and approved, does not imply approval of an exception from these requirements.

(Code 2009, § 15.05.070)

Ask a question about Longmont law

Corpus searches the Longmont sections it holds and shows the ones that match, with their citations. Free, no sign-in.