For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.05.120 — Mixed-use and nonresidential design standard

Code of Ordinances of the City of Longmont, Colorado (Codified through Ordinance No. O-2026-39, enacted June 23, 2026 (Supp. No. 9)) · Longmont Code of Ordinances § 15.05.120

Corpus is an independent public-information project, not the official City of Longmont website. Stable reference: corpuslaw.us/code/8d60426a-de69-4e13-90ab-e3f425e7aa3e

Sec. 15.05.120. - Mixed-use and nonresidential design standard.

A. Purpose. The mixed-use and nonresidential design standards are intended to implement comprehensive plan strategies and to promote high-quality design of an urban environment. The standards are further intended to: 1. Protect and enhance the character and quality of the city's neighborhoods; 2. Provide visual interest and variety; 3. Enhance the pedestrian scale of development and the streetscape; 4. Mitigate negative visual impacts from the scale, bulk, and mass of large buildings; 5. Balance the community's economic and aesthetic goals; and 6. Encourage building and site design that fosters community sustainability goals, including adaptive reuse, energy efficient design, and incorporating alternative energy systems. B. Applicability. This section shall apply to: 1. Mixed-use and nonresidential development. 2. Modifications or additions to existing mixed-use or nonresidential development, but only to the portion of the development being modified. C. General design standards. 1. Site layout. a. Compatibility with natural site conditions. i. Development shall be avoided on sites with steep slopes and other sensitive environmental and natural areas and habitat to the maximum extent practicable. ii. Building envelopes and areas of site disturbance shall be selected based on the location of natural landforms, native vegetation, mature trees, underlying geology, mapped hazard areas, and setbacks required pursuant to this development code. b. Compatibility and coordination with adjacent development. Development shall respect local development patterns and site features to the maximum extent practicable. Elements that shall be coordinated between adjacent sites include: i. Shared driveways for access; ii. Linkages of internal vehicular and pedestrian circulation systems; iii. Linkages of open space systems; iv. Areas and access for refuse and recycling collection, loading and storage; v. Drainage and detention facilities; and vi. Other improvements where a coordinated approach benefits the larger area. c. Pedestrian gathering spaces. Outdoor spaces for pedestrians, such as plazas, courtyards, outdoor seating areas, and other amenities with connecting pedestrian paths shall be included with mixed-use and nonresidential developments to the maximum extent practicable, pursuant to section 15.05.040.H.1. d. Developments with multiple buildings. Buildings shall be arranged on the site so that their orientation frames, encloses, or otherwise gives prominence to a pedestrian corridor, an outdoor gathering space, a main street pedestrian or vehicle access corridor within the site, or the corners of street intersections or entry points into the development. e. Design for security. Sites shall be designed to avoid the creation of areas that are shielded on multiple sides by barriers such as screen walls or landscaping that have low visibility. Such areas shall be avoided in site design to the maximum extent practicable or shall otherwise be well-lit and have some form of surveillance. 2. Building design. Mixed-use and nonresidential buildings shall comply with subsection 15.05.120.C.3 through C.10, except as otherwise stated in subsection C.11 below. 3. Building entrances. a. Primary building entrances shall be oriented toward streets, pedestrian walkways and plazas, with direct, continuous connections to the street without requiring pedestrians to walk through parking areas. b. Entrances for buildings on a corner shall be chamfered at a 45-degree angle at least ten feet from the building corner to face the intersection of such corner to the maximum extent practicable. c. Buildings that front on the St. Vrain Creek, parks, plazas, common areas and public open spaces shall have a primary building facade with a customer entrance that faces the common or public area. d. All customer or resident/visitor entrances shall create architectural interest and variation from other portions of the building by incorporating at least three of the following: i. Changes in building plane through recesses and/or projections; ii. Canopies, awnings, arcades, galleries, or other overhangs; iii. Tower elements; iv. Architectural embellishments; v. Changes in building material, color, and/or texture; or vi. Other design elements that add visual interest as determined by the director. 4. Building articulation. a. Horizontal articulation. i. Each building façade greater than 50 feet in length shall incorporate wall plane projections or recesses that are compatible with the proposed building use and architecture. Wall plane projections and recesses may also include distinctive architectural character features, such as recessed windows, columns or an equivalent element, or other features that vary a wall plane, as determined by the director. ii. Additionally, each building façade shall incorporate a change of materials (A) and at least two of the following elements (B through E) (see Figure 5.5): (A) Change in building materials—at least three materials for a façade facing a street or other public area, or facing a residential or mixed use zoning district, and at least two materials for other facades; (B) Change in building colors; (C) Change in textures or patterns; (D) Variation in window design; or (E) Other design elements that add visual interest as determined by the director. Figure 5.5: Horizontal Articulation [image omitted; see the official code] b. Vertical articulation. Principal mixed-use and nonresidential multistory buildings, and one story buildings taller than 20 feet, shall be designed so that the massing or facade articulation of the building presents a clear base, middle, and top. First floors in mixed-use districts shall be designed with adequate floor to ceiling height to accommodate storefronts to the maximum extent practicable. Lower levels can be differentiated from upper stories by incorporation of elements including, but not limited to, the following (See Figure 5.6): i. Low planters and walls; ii. Use of veneer banding or wainscot, change in materials, and change in textures; iii. Heavier materials and darker colors on lower levels; iv. Integrated covered walkways, trellises, or architectural awnings; or v. Other design elements that distinguish lower levels as determined by the director. Figure 5.6: Vertical Articulation for Multiple Story Buildings [image omitted; see the official code] c. Corner building articulation. Buildings located at the intersection of two streets or on axis with a terminating street or plaza shall be designed to incorporate prominent architectural elements to the maximum extent practicable, such as increased building height or massing with a tower element with a pitched roof or extended canopy. d. Upper story floor area standard. The upper-most story of all buildings greater than two stories shall have a reduced floor area of at least ten percent of the ground floor (figure 5.7). Figure 5.7: Upper Story Floor Area Standard [image omitted; see the official code] e. Comprehensive design. i. Building façades facing a street or other public area, or facing or within a residential or mixed-use zoning district or development shall be designed with a similar level of detail, patterning, and finish through the use of similar architectural features, building materials, and design of landscaping features. Blank walls void of architectural detailing shall be prohibited unless the director determines that the façade is not visible from adjacent development or public rights-of-way. ii. Accessory building facades shall be designed and finished to complement primary buildings through the use of similar colors, materials, and architectural style. 5. Roof and parapet design. a. No roofline or parapet along any building elevation shall be continuous without variation that incorporates any of the following: i. Projections or recesses; ii. Dormers; iii. Changes in roof or parapet height iv. Distinctive detailed cornices; or v. Other distinct architectural features as determined by the director. b. Roofs of buildings shall have parapets or enclosures concealing flat roofs and roof-top equipment from public view, and such parapets and enclosures shall be constructed of materials that match the building in quality and detail. Each such parapet or enclosure shall have an average height of no more than 15 percent of the height of the supporting wall, a maximum height at any point equal to 33 percent of the height of the supporting wall, and three-dimensional cornice treatments. c. Roofs shall be designed to accommodate solar energy systems to the maximum extent practicable. 6. Ground-floor design. a. Ground-floor facades facing a street or other public area shall have arcades, display windows, entry areas, awnings, or other such features along at least 60 percent of the horizontal length. b. Ground-floor residential units with direct access to a public sidewalk or other public right-of-way shall comply with the design standards for multifamily dwellings in section 15.05.110.I.2. 7. Transparency (windows, doors and openings). a. Ground floor façades facing a street or other public area shall contain a minimum of 50 percent windows or doorways (Figure 5.8). b. Upper floor facades facing public street or other public area shall contain a minimum of 15 percent windows (figure 5.8). c. Clear glass shall be used for storefront display windows and doors. d. Windows shall be accented and defined with detail elements, such as frames, sills, and lintels, and shall be located to visually establish and define the street or pedestrian ways facing portions of a building and to establish human scale and proportion. Figure 5.8: Building Transparency [image omitted; see the official code] 8. Building materials. a. Generally. Building materials shall either be similar to the materials already being used in the existing neighborhood or, if dissimilar materials are being proposed, other characteristics such as scale and proportions, form, architectural detailing, color, and texture shall be used to ensure compatibility despite the differences in materials. b. Allowable building materials. Allowable materials include: i. Primary materials. The following primary materials may comprise more than 50 percent of any building facade: (A) Fire clay brick; (B) Natural stone; (C) Clear glass; (D) Cementitious stucco; (E) Other quality materials, such as repurposed materials, as determined by the director under subsection C.12 below. ii. Secondary materials. The following secondary materials shall not comprise more than 50 percent of any building facade: (A) Architectural tiles; (B) Quality architectural metal panels; (C) Fiber cement board; (D) Quality wood or composite siding or panels; (E) Split face and ground face masonry block; (F) Other quality materials as determined by the director under subsection C.12 below. c. Metal panels and roofs. i. Quality architectural metal panels may be used as architectural and accent features, but shall not be the primary exterior material on any building façade, except that in the MU-E, N-PE, N-PF and N-AG zoning districts building facades not facing a street or other public area, or a residential or mixed-use district or development, may have quality architectural metal panels as the primary exterior material. ii. Quality metal roof designs that include eaves and overhangs for visual interest are allowed and shall not count toward any limit on metal used on a building exterior. 9. Exterior color. Mixed-use and nonresidential developments shall include a variety of exterior color palettes to provide diversity within the development. Color palettes shall be compatible with surrounding development to the maximum extent practicable. Fluorescent colors and glossy finishes shall not be used on any exterior wall or roof of any structure. 10. Parking structure design. Parking structures shall be designed as follows to the maximum extent practicable: a. Facades facing a street or other public area, residential or mixed-use district shall comply with the building materials requirements of subsection C.7 of this section; b. The first story shall include storefronts along the street facing facade except for necessary street access to the parking structure; c. Upper floor parking decks shall be designed to screen vehicles; and d. The top parking deck shall be designed to accommodate shade structures and solar energy systems. 11. Industrial building design. a. Applicability. Unless exempted herein, this section shall apply to the following industrial buildings located within the MU-E, N-PE, or N-PF zoning districts and not adjacent to a residential zoning district or an existing or planned residential or mixed-use development in a mixed-use district other than MU-E: i. Light and medium industrial buildings; and ii. Warehouse or storage facility buildings; and iii. Transportation depot, trucking terminal or distribution center buildings; and iv. Other similar buildings designed for industrial uses or public services with the majority of the building area used for manufacturing and processing, warehousing, storage, maintenance, distribution or truck loading uses. b. Site layout. Site design shall comply with subsection C.1, except that pedestrian gathering spaces under subsection C.1.c are encouraged where appropriate considering the site design. c. Building entrances. Building entrances shall comply with subsections C.3.a, C.3.c, and C.3.d above. d. Horizontal articulation. Building facades shall comply with subsection C.4.a above, except that for subsection C.4.a.i, wall plane projections are required only along building facades facing a street or other public area, or portions of other facades where customer entrances and offices are located. e. Vertical articulation. Building facades facing a street or other public area, or portions of other facades where customer entrances and offices are located are subject to subsection C.4.b. above. f. Corner building articulation, upper story floor area and comprehensive design. Building designs shall comply with subsections C.4.c and C.4.e above. g. Roof and parapet design. Building roofs and parapets shall comply with subsection C.5 above, except that for subsection C.5.a, roofline and parapet variations are required only along the building facades facing a street or other public area, or portions of other facades where customer entrances and offices are located. h. Transparency. Building facades facing a street or other public area shall include windows and doors on at least 25 percent of the horizontal length of the façade, or the portion of the building facade that includes customer entrances and offices, whichever is greater. The size and location of the windows shall be compatible and proportional to the building design. Windows may be clear or tinted/spandrel glass. Building facades shall include clear windows and doors on the portion of the façade that includes customer entrances and offices. i. Building materials. Exterior building materials shall comply with subsection C.8 above, except that the following exterior materials are also allowed as primary materials: i. Architectural precast or site cast tilt up concrete with quality compatible finishes and colors; ii. Quality aluminum composite material metal panels, such as Alucabond or Reynobond; iii. Quality insulated metal panels with textured finishes; iv. Other materials that add visual interest as determined by the director. j. Exterior color. Exterior colors shall comply with subsection C.9 above. 12. Alternative design compliance. Alternative building designs, including but not limited to site layout, building entrances, horizontal, vertical and corner building articulation, upper story floor area, comprehensive design, roof and parapet design, transparency, building materials, exterior colors, and parking structure design may be allowed if the director, through an administrative modification under subsection 15.02.080.B, determines that the design creates a quality or unique building design that meets the purpose and intent of the standards in this section consistent with the building design and use, orientation, placement and location context.

(Code 2009, § 15.05.120; Ord. No. O-2023-11, § 2, 3-21-2023)

Ask a question about Longmont law

Corpus searches the Longmont sections it holds and shows the ones that match, with their citations. Free, no sign-in.