§ 10-152 — Amendments to International Building Code
Code of the City of Thornton, Colorado (Supp. No. 65: codified through Ordinance No. 3773, adopted June 9, 2026) · Thornton City Code § 10-152
Corpus is an independent public-information project, not the official City of Thornton website. Stable reference: corpuslaw.us/code/487d3e8f-8d44-43c2-a88d-298adf334726
Sec. 10-152. - Amendments to International Building Code.
The International Building Code adopted in Section 10-151 is hereby amended as follows, with section numbers referring to section numbers of the International Building Code: Subsection 101.1 is hereby amended to read as follows: 101.1 Title. These regulations shall be known as the Building Code of the City of Thornton, hereinafter referred to as "this code." Subsection 101.4.4 is hereby amended to read as follows: 101.4.4 Property maintenance. The provisions of the International Existing Building Code and the Uniform Code for the Abatement of Dangerous Buildings shall apply to existing structures and premises; equipment and facilities; light, ventilation, space heating, sanitation, life and fire safety hazards; responsibilities of owners, operators and occupants; and occupancy of existing premises and structures. Subsection 102.6 is hereby amended to read as follows: 102.6 Existing structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change, except as is specifically covered in this code, the Uniform Code for the Abatement of Dangerous Buildings, the International Existing Building Code, or the International Fire Code. Subsections 114.1 and 114.2 are hereby amended to read as follows: [A] 114.1 Unlawful acts. It shall be unlawful for any person, firm or corporation to erect, construct, alter, extend, repair, move, remove, demolish or occupy any building, structure or equipment regulated by this code, or cause same to be done, in conflict with or in violation of any of the provisions of this code. Additionally, any property owner may be held liable for any of the above referenced actions taken by any person in violation of any of the provisions of this code on the property owner's property. [A] 114.2 Notice of violation. The building official is authorized to serve a notice of violation or order on any person or property owner who violates Subsection 114.1. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. Section 202 Definitions; [BS] DANGEROUS is hereby amended to read as follows: [BS] DANGEROUS. Any building, structure or portion thereof that meets any of the conditions described below or meets the definition of dangerous as stated in the Uniform Code for the Abatement of Dangerous Buildings shall be deemed dangerous: 1. The building or structure has collapsed, has partially collapsed, has moved off its foundation or lacks the support of the ground. 2. There exists a significant risk of collapse, detachment or dislodgement of any portion, member, appurtenance or ornamentation of the building or structure under permanent, routine, or frequent loads; under actual loads already in effect; or under snow, wind, rain, flood, earthquake, or other environmental loads when such loads are imminent. Section 202 Definitions is hereby amended to read as follows: SLEEPING ROOM. A habitable space that meets the minimum area requirements of the building code, and, contains a closet or an area that is readily convertible to a closet. An adjacent area fitted with permanently affixed floor to ceiling shelving and no clothes rod may be defined as a storage room in a non-sleeping room. A new Subsection 915.1.2. is hereby enacted to read as follows: 915.1.2 Where required in existing dwellings. Where interior work requiring a permit occurs in existing Group I or R occupancies that have attached garages or contain fuel-fired appliances, carbon monoxide detection shall be provided in locations described in Section 915.2.1 through 915.2.2. A listed smoke/carbon monoxide detector may be used if the signals clearly differentiate between the two hazards. Carbon monoxide detectors may be hard wired, plugged into an unswitched outlet or battery powered and attached to the wall or ceiling. Carbon monoxide detectors are not required to be interconnected. Subsection 915.2.1 is hereby amended to read as follows: 915.2.1 Dwelling units. Carbon monoxide detection shall be installed in dwelling units outside of each separate sleeping area within fifteen feet (4572 mm) of the entrance to each bedroom. Where a CO source is located within a bedroom or its attached bathroom, carbon monoxide detection shall be installed within the bedroom. Subsection 1031.2 is hereby amended to read as follows: 1031.2 Where required. In addition to the means of egress required by this chapter, emergency escape and rescue openings shall be provided in the following occupancies: 1. Group R-2 occupancies located in stories with only one exit or access to only one exit as permitted by Tables 1006.3.4(1) and 1006.3.4(2). 2. Group R-3 and R-4 occupancies. Basements and sleeping rooms below the fourth story above grade plane shall have not fewer than one emergency escape and rescue opening in accordance with this section. Where basements contain one or more sleeping rooms, an emergency escape and rescue opening shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Such openings shall open directly into a public way or to a yard or court that opens to a public way. Exceptions: 1. Emergency escape and rescue openings are not required from basements or sleeping rooms that have an exit door or exit access door that opens directly into a public way or to a yard, court or exterior egress balcony that opens to a public way. 2. Basements without habitable spaces and having no more than 200 square feet (18.6 m 2 ) in floor area shall not be required to have emergency escape and rescue openings. 3. Storm shelters are not required to comply with this section where the shelter is constructed in accordance with ICC 500. Subsection 1031.3.1 is hereby amended to read as follows: 1031.3.1 Minimum size. Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.53 m 2 ). Subsection 1031.6 is hereby amended to read as follows: 1031.6 Bars, grilles, covers and screens. Where bars, grilles, covers, screens or similar devices are placed over emergency escape and rescue openings or area wells that serve such openings, the minimum net clear opening size shall comply with Sections 1031.3 and 1031.5. Such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Such bars, grilles, or grates shall weigh no more than 30 pounds (13.6 kg). Where such bars, grilles, grates or similar devices are installed in existing buildings, smoke alarms shall be installed in accordance with Section 907.2.11 regardless of the valuation of the alteration. Subsection 1209.1 is hereby amended to read as follows: 1209.1 Crawl spaces. Crawl spaces shall be provided with not less than one access opening that shall be not less than 22 inches by 30 inches (559 mm by 762 mm). A new Subsection 1512.1.2 is hereby enacted to read as follows: 1512.1.2 Replacement of asphalt shingles. When more than one square of asphalt shingles is required to be replaced over the aggregate area of the roof and a permit is required, every slope containing damaged shingles shall be replaced in its entirety. The interface of different types of shingles shall only occur at a ridge, hip or open valley. All existing layers of asphalt shingles shall be removed to the roof deck. Subsection 1612.3 is hereby amended to read as follows: 1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the applicable governing authority shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in a report entitled "The Flood Insurance Study for the City of Thornton dated December 2, 2021 as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and Flood Boundary and Floodway Map (FBFM) and related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. Subsection 1805.4.3 is hereby amended to read as follows: 1805.4.3 Drainage discharge. The floor base and foundation perimeter drain shall be designed to collect in a sump and discharge by gravity and mechanical means into an approved drainage system that complies with the International Plumbing Code. Table 2902.1 is hereby amended to read as follows: [P]TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa(See Sections 2902.1.1 and 2902.2) No. | Classification | Description | Water Closets (Urinals See Section 424.2 of The International Plumbing Code) | Lavatories | Bathtubs/Showers | Drinking Fountains (See Section 410 of The International Plumbing Code) g | Other Male | Female | Male | Female 1 | Assembly | Theaters and other buildings for the performing arts and motion pictures d | 1 per 125 | 1 per 65 | 1 per 200 | — | 1 per 500 | 1 service sink Nightclubs, bars, taverns, dance halls and buildings for similar purposes d | 1 per 40 | 1 per 40 | 1 per 75 | — | 1 per 500 | 1 service sink Restaurants, banquet halls and food courts d | 1 per 75 | 1 per 75 | 1 per 200 | — | 1 per 500 | 1 service sink Casino gaming areas | 1 per 100 for the first 400 and 1 per 250 for the remainder exceeding 400 | 1 per 50 for the first 400 and 1 per 150 for the remainder exceeding 400 | 1 per 250 for the first 750 and 1 per 500 for the remainder exceeding 750 | — | 1 per 1,000 | 1 service sink Auditoriums without permanent seating, art galleries, exhibition halls, museums, lecture halls, libraries, arcades and gymnasiums d | 1 per 125 | 1 per 65 | 1 per 200 | — | 1 per 500 | 1 service sink Passenger terminals and transportation facilities d | 1 per 500 | 1 per 500 | 1 per 750 | — | 1 per 1,000 | 1 service sink Places of worship and other religious services d | 1 per 150 | 1 per 75 | 1 per 200 | — | 1 per 1,000 | 1 service sink Coliseums, arenas, skating rinks, pools and tennis courts for indoor sporting events and activities | 1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 | 1 per 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 | 1 per 200 | 1 per 150 | — | 1 per 1,000 | 1 service sink No. | Classification | Description | Water Closets (Urinals See Section 424.2 of The International Plumbing Code) | Lavatories | Bathtubs/Showers | Drinking Fountains (See Section 410 of The International Plumbing Code) g | Other Male | Female | Male | Female Stadiums, amusement parks, bleachers and grandstands for outdoor sporting events and activities f | 1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 | 1 per 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 | 1 per 200 | 1 per 150 | — | 1 per 1,000 | 1 service sink 2 | Business | Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, light industrial, ambulatory care and similar uses | 1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50 | 1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80 | — | 1 per 100 | 1 service sink e 3 | Educational | Educational facilities | 1 per 50 | 1 per 50 | — | 1 per 100 | 1 service sink 4 | Factory and industrial | Structures in which occupants are engaged in work fabricating, assembly or processing of products or materials | 1 per 100 | 1 per 100 | — | 1 per 400 | 1 service sink 5 | Institutional | Custodial care facilities | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink Medical care recipients in hospitals and nursing homes b | 1 per room c | 1 per room c | 1 per 15 | 1 per 100 | 1 service sink Employees in hospitals and nursing homes b | 1 per 25 | 1 per 35 | — | 1 per 100 | — Visitors in hospitals and nursing homes | 1 per 75 | 1 per 100 | — | 1 per 500 | — Prisons b | 1 per cell | 1 per cell | 1 per 15 | 1 per 100 | 1 service sink Reformatories, detention centers and correctional centers b | 1 per 15 | 1 per 15 | 1 per 15 | 1 per 100 | 1 service sink Employees in reformatories, detention centers and correctional centers b | 1 per 25 | 1 per 35 | — | 1 per 100 | — Adult day care and child day care | 1 per 15 | 1 per 15 | 1 | 1 per 100 | 1 service sink 6 | Mercantile | Retail stores, service stations, shops, salesrooms, markets and shopping centers | 1 per 500 | 1 per 750 | — | 1 per 1,000 | 1 service sink e 7 | Residential | Hotels, motels, boarding houses (transient) | 1 per sleeping unit | 1 per sleeping unit | 1 per sleeping unit | — | 1 service sink Dormitories, fraternities, sororities and boarding houses (not transient) | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink Apartment house | 1 per dwelling unit | 1 per dwelling unit | 1 per dwelling unit | — | 1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per 20 dwelling units One- and two- family dwellings and lodging houses with five or fewer guestrooms | 1 per dwelling unit | 1 per 10 | 1 per dwelling unit | — | 1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per dwelling unit Congregate living facilities with 16 or fewer persons | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink 8 | Storage | Structures for the storage of goods, warehouses, storehouses and freight depots, low and moderate hazard | 1 per 100 | 1 per 100 | — | 1 per 1,000 | 1 service sink a. The fixtures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction of the number of persons indicated. The number of occupants shall be determined by this code. b. Toilet facilities for employees shall be separate from facilities for inmates or care recipients. c. A single-occupant toilet room with one water closet and one lavatory serving not more than two adjacent patient sleeping units shall be permitted, provided that each patient sleeping unit has direct access to the toilet room and provisions for privacy for the toilet room user are provided. d. The occupant load for seasonal outdoor seating and entertainment areas shall be included when determining the minimum number of facilities required. e. For business classifications with an occupant load of 25 or fewer, and mercantile classifications with an occupant load of 42 or fewer, a service sink shall not be required. f. The required number and type of plumbing fixtures for outdoor swimming pools shall be in accordance with Section 609 of the International Swimming Pool and Spa Code. g. Drinking fountains are not required where only one toilet room is required.
(Ord. No. 2993, § 2, 6-5-07, eff. 7-2-07; Ord. No. 3136, § 5, 7-13-10; Ord. No. 3252, § 8, 7-23-13; Ord. No. 3398, § 5, 8-23-16; Ord. No. 3538, § 4, 9-10-19; Ord. No. 3643, § 3, 2-14-23; Ord. No. 3731, § 4, 5-13-25)
Ask a question about Thornton law
Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.