§ 10-177 — Amendments to the International Existing Building Code

Code of the City of Thornton, Colorado (Supp. No. 65: codified through Ordinance No. 3773, adopted June 9, 2026) · Thornton City Code § 10-177

Corpus is an independent public-information project, not the official City of Thornton website. Stable reference: corpuslaw.us/code/88469cfe-19d1-4bd1-ac21-b20974610e6f

Sec. 10-177. - Amendments to the International Existing Building Code.

The International Existing Building Code adopted in Section 10-176 is amended as follows, with section numbers referring to section numbers of the International Existing Building Code: Subsection 101.1 is hereby amended to read as follows: [A] 101.1 Title. These regulations shall be known as the Existing Building Code of the City of Thornton, hereinafter referred to as "this code." Subsection 101.2 is hereby amended to read as follows: [A] 101.2 Scope. The provisions of this code shall apply to the repair, alteration, change of occupancy, addition and relocation of existing buildings. The relocation of existing buildings shall also comply with City Code Section 18-517. Section 202 General Definitions is hereby amended to read as follows: COLD WEATHER CARE HOUSING. Places of religious worship within the City that allow the temporary housing of homeless persons during the months of October through March. [BS] DANGEROUS. Any building, structure or portion thereof that meets any of the conditions described below or meets the definition of dangerous as stated in the Uniform Code for the Abatement of Dangerous Buildings shall be deemed dangerous: 1. The building or structure has collapsed, has partially collapsed, has moved off its foundation or lacks the necessary support of the ground. 2. There exists a significant risk of collapse, detachment or dislodgment of any portion, member, appurtenance or ornamentation of the building or structure under permanent, routine or frequent loads; under actual loads already in effect; or under snow, wind, rain, flood, earthquake or other environmental loads when such loads are imminent. Section 308.1 is hereby amended to read as follows: 308.1 Carbon monoxide detection. Where an addition, alteration, change of occupancy or relocation of a building is made to Group I-1, I-2, I-4 and R occupancies and classrooms of Group E occupancies, or where one or more sleeping rooms are added or created in existing dwellings, the existing building shall be provided with carbon monoxide detection in accordance with the International Fire Code or Section R315 of the International Residential Code. Exceptions: 1. Work involving the exterior surfaces of buildings, such as the replacement of roofing or siding, the addition or replacement of windows or doors, or the addition of porches or decks. 2. Installation, alteration or repairs of plumbing or mechanical systems, other than fuel-burning appliances. Section 705 is hereby repealed in its entirety. Please refer to Section 1511 of the International Building Code. Subsection 1011.2.1 is hereby amended to read as follows: 1011.2.1 Fire sprinkler system. Where a change in occupancy classification occurs or where there is a change of occupancy within a space where there is a different fire protection system threshold requirement in Chapter 9 of the International Building Code that requires an automatic fire sprinkler system to be provided based on the new occupancy in accordance with Chapter 9 of the International Building Code. The installation of the automatic sprinkler system shall be required within the area of the change of occupancy and areas of the building not separated horizontally and vertically from the change of occupancy by one of the following: 1. Nonrated permanent partition and horizontal assemblies. 2. Fire partition. 3. Smoke partition. 4. Smoke barrier. 5. Fire barrier. 6. Fire wall. Exceptions: 1. An automatic sprinkler system shall not be required in a one- or two-family dwelling constructed in accordance with the International Residential Code. 2. Automatic sprinkler system shall not be required in a townhouse constructed in accordance with the International Residential Code. 3. The townhouse shall be separated from adjoining units in accordance with Section R302.2 of the International Residential Code. 4. Group A-3 places of religious worship participating in the Cold Weather Care Housing, as defined in Chapter 2, in which the aggregate sleeping areas are less than ten percent (10%) of the building area for each story that is used as an aggregate sleeping area.

(Ord. No. 3136, § 31, 7-13-10; Ord. No. 3157, § 1, 12-7-10; Ord. No. 3165, § 2, 4-12-11; Ord. No. 3252, § 22, 7-23-13; Ord. No. 3398, § 16, 8-23-16; Ord. No. 3538, § 18, 9-10-19; Ord. No. 3643, § 17, 2-14-23; Ord. No. 3731, § 17, 5-13-25; Ord. No. 3745, § 9, 8-26-25)

Ask a question about Thornton law

Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.