Sec. 10-165. - Amendments to the International Residential Code.
The International Residential Code adopted in Section 10-164 is amended as follows, with section numbers referring to section numbers of the International Residential Code: Subsection R101.1 is hereby amended to read as follows: R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-Family Dwellings of the City of Thornton, and shall be cited as such and will be referred to herein as "this code." Subsection R102.7 is hereby amended to read as follows: R102.7 Existing structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change, except as is specifically covered in this code, the International Existing Building Code or the International Fire Code, or as is deemed necessary by the building official for the general safety and welfare of the occupants and the public. Subsection R202 is hereby amended to read as follows: SLEEPING ROOM. A habitable space that meets the minimum area requirements of the building code and contains a closet or an area that is readily convertible to a closet. An adjacent area fitted with permanently affixed floor to ceiling shelving and no clothes rod may be defined as a storage room in a non-sleeping room. Subsection R202 is hereby amended to read as follows: DWELLING UNIT. A single unit providing complete independent living facilities, for one or more persons, including permanent provisions for living, sleeping, eating, cooking and sanitation. Independent, in this circumstance, means having a separate designated entrance and address. For the definition applicable in Chapter 11, see Section N1101.6. For the definition applicable in Chapter 24, see section G2403. Table R301.2 is hereby repealed and reenacted to read as follows: Table R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load o | Wind Design | Seismic Design Category f | Subject To Damage From | Ice Barrier Under-layment Required h | Flood hazards g | Air Freezing Index i | Mean Annual Temp j Speed d (mph) | Topographic effects k | Special wind region l | Windborne debris zone m | Weathering a | Frost line depth b | Termite c 30 psf | 105 ult | NO | NO | NO | B | Severe | 36" | sli to mod | NO | IBC 1612.3 | 1500 | 45°F MANUAL J DESIGN CRITERIA n Elevation | Altitude correction factor e | Coincident wet bulb | Indoor winter design relative humidity | Indoor winter design dry-bulb temperature | Outdoor winter design dry-bulb temperature | Heating temperature difference 5,344 ft | 0.84 | 59°F | 50% | 70°F | 1°F | 69°F Latitude | Daily range | Summer design gains | Indoor summer design relative humidity | Indoor summer design dry-bulb temperature | Outdoor summer design dry-bulb temperature | Cooling temperature difference 40°N | High(H) | — | 50% | 75°F | 91°F | 16°F For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(1). The grade of masonry units shall be determined from ASTM C34, ASTM C55, ASTM C62, ASTM C73, ASTM C90, ASTM C129, ASTM C145, ASTM C216 or ASTM C652. b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the ultimate design wind speeds map [Figure R301.2(2)]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. The jurisdiction shall fill in this section of the table to establish the design criteria using Table 10A from ACCA Manual J or established criteria determined by the jurisdiction. f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. The jurisdiction shall fill in this part of the table with: the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas); and the title and date of the currently effective Flood Insurance Study or other flood hazard study and maps adopted by the authority having jurisdiction, as amended. h. In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO." i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. l. In accordance with Figure R301.2(2), where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. o. The jurisdiction shall fill in this section of the allowable stress design table using the Ground Snow Loads in Figure R301.2(3). For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. Subsections R302.3 is hereby amended to read as follows: R302.3 Two-family dwellings. Dwelling units in two-family dwellings shall be separated from each other in accordance with sections 302.3.1 through 302.3.5. Dwelling units in two-family dwellings divided by a legal property line shall be separated by fire resistance-rated wall assemblies meeting the requirements of Section R302.2 for Townhouses. Subsection R302.13 is hereby repealed in its entirety. Subsection R309.1 is hereby repealed in its entirety. Subsection R309.2 is hereby repealed in its entirety. Subsection R310.6 is hereby amended to read as follows: R310.6 Power source. Smoke alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and, where primary power is interrupted, shall receive power from a 10-year battery. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. Exceptions: 1. Smoke alarms shall be permitted to be battery operated where installed in buildings without commercial power. 2. Smoke alarms installed in accordance with Section R314.2.2 shall be permitted to be battery powered. Subsection R310.7.4 is hereby amended to read as follows: R310.7.4 Combination detectors. Combination smoke and carbon monoxide detectors shall be permitted to be installed in fire alarm systems in lieu of smoke detectors, provided that they are listed in accordance with UL 268 and UL 2075. Battery power alarms shall be rated for the life of the device. Subsection R311.3 is hereby amended to read as follows: R311.3 Location. Carbon monoxide alarms in dwelling units shall be installed outside of each separate sleeping area within 15 feet (4572 mm) of each bedroom. Where a fuel-burning appliance is located within a bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom. Subsection R319.1 is hereby amended to read as follows: R319.1 Emergency escape and rescue opening required. Basements, habitable attics, the room to which a sleeping loft is open, and every sleeping room shall have not less than one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, an emergency escape and rescue openings shall be required in each sleeping room. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court having a minimum width of 36 inches (914 mm) that opens to a public way. Exceptions: 1. Basements used only to house mechanical equipment not exceeding a total floor area of 200 square feet (18.58 m 2 ). 2. Storm shelters constructed in accordance with ICC 50. 3. A yard shall not be required to open directly into a public way where the yard opens to an unobstructed path from the yard to the public way. Such path shall have a width of not less than 36 inches (914 mm). Subsection R319.2 is hereby amended to read as follows: R319.2 Emergency escape and rescue openings. Emergency Escape and rescue openings and all below grade windows in unfinished basements shall have minimum dimensions in accordance with Sections R319.2.1 through R319.2.4 Subsection R319.2.1 is hereby amended to read as follows: R319.2.1 Minimum size. Emergency escape and rescue openings shall have a net clear opening of not less than 5.7 square feet (0.530 m 2 ). Subsection R319.4 is hereby amended to read as follows: R319.4 Area wells. Emergency escape and rescue openings and all below grade windows in unfinished basements where the bottom of the clear opening is below the adjacent grade shall be provided with an area well in accordance with Sections R310.4.1 through R310.4.4. Subsection R319.4.4 is hereby amended to read as follows: R319.4.4 Bars, grilles, covers and screens. Where bars, grilles, covers, screens or similar devices are placed over emergency escape and rescue openings, bulkhead enclosures or area wells that serve such openings, the minimum net clear opening size shall comply with Sections R319.2.1 through R319.2.2 and R319.4.1. Such devices shall be releasable or removable from the inside without the use of a key or tool or force greater than that which is required for normal operation of the escape and rescue opening. Such devices shall weigh no more than 30 lbs (13.6 kg). A new Section R333 is hereby enacted to read as follows: SECTION R333 MANUFACTURED HOMES R333.1 General. All manufactured homes shall be installed and inspected in accordance with the State of Colorado Manufactured Home Installation Program and the provisions of this section. R333.2 Existing Manufactured Homes 1. Whenever a manufactured home is in existence in the City on the effective date of the ordinance from which this section derives or was annexed to the City after the effective date and such manufactured home complies with all applicable codes and ordinances then in effect, the manufactured home shall be considered to be legally nonconforming and shall not be subject to the provisions of this section. 2. In the event that any such legally nonconforming manufactured home is removed from its location, the manufactured home shall be replaced or relocated, except in conformance with all applicable provisions of the building code. In addition, if the use of such manufactured home is discontinued for a period of six consecutive months or more, the manufactured home shall not be reoccupied until it is in conformance with all applicable regulations in the building code. R333.3 Additions, alterations and repairs. Additions, alterations and repairs to manufactured homes shall be designed and constructed in accordance with the currently adopted residential code. Additions and alterations shall be structurally independent from the manufactured home. Exception: A structural separation need not be provided when the plans and specifications have been prepared and sealed by a design professional. R333.4 Definition. MANUFACTURED HOME PARK. The terms manufactured home park (MHP) or manufactured home rental community (park) are interchangeable terms for the purposes of this section meaning a unified residential development of manufactured homes arranged on a lot under a single ownership. R333.5 Skirting and permanent perimeter enclosures. Skirting and permanent perimeter enclosures shall be installed on all manufactured home within 60 days of approval of the utilities inspection. Skirting shall be of material suitable for exterior exposure and contact with the ground. Permanent perimeter enclosures shall be constructed of materials as required by this code for regular foundation construction. Skirting shall be installed in accordance with the skirting manufacturer's installation instructions. Skirting shall be adequately secured to assure stability, to minimize vibration and susceptibility to wind damage, and to compensate for possible frost heave. All skirting shall have one or more openings not less than 18 inches (457 mm) in any dimension and not less than 3 square feet (.2787 m 2 ) in area so constructed and located to allow convenient access to all points of utilities connections. The location and design of such openings shall be approved by the Building Inspection Division. R333.6 Smoke detectors. Manufactured homes built prior to March 2003 shall be equipped with battery powered smoke detectors with a battery rated for a 10-year life, provided the smoke detector is listed for use with a 10-year battery. The smoke detectors shall be placed as required by the currently adopted residential code. Manufactured homes built in March 2003 and later shall have each smoke detector powered from either the electrical system of the home as the primary power source and a battery as a secondary power source; or a battery rated for a 10-year life, provided the smoke detector is listed for use with a 10-year battery. The smoke detectors shall be placed as required by the currently adopted residential code. Regardless of the power source, smoke detectors are required to be interconnected such that the activation of any one smoke detector will cause the alarm to be triggered in all required smoke detectors in the home. R333.7 Carbon monoxide detectors. Carbon monoxide detectors shall be installed in accordance with the provisions of Section R315 of this code. R333.8 Accessory buildings and structures. The following general requirements apply to all mobile home accessory buildings and structures: 1. Location on space. Accessory buildings and structures shall not obstruct required openings for light and ventilation of the mobile home and shall not prevent inspection of mobile home equipment and utility connections. 2. Construction. Every accessory building or structure shall be designed and constructed in accordance with the applicable provisions of all City building and construction codes, laws and ordinances. All awnings and carports within manufactured home parks shall conform with the following specific requirements: 1. Generally. An awning or carport may be erected, constructed or maintained on a manufactured home space only as an accessory to a manufactured home located on the same space. An awning shall not be enclosed with rigid materials or walls or converted for use as a habitable room or cabana, unless the completed construction complies with all the requirements for a cabana. 2. Location. Awnings or carports may be attached to the manufactured home when in compliance with Section R328.3 3. Exits from awning enclosure. An awning with enclosures of non-rigid materials shall have at least one door in the enclosure opening directly to the outside of the enclosure. The opening shall be not less than 28 inches (711 mm) in width nor less than six feet, two inches in height (1880 mm). Two such door openings shall be provided from the enclosure when the enclosure encloses two doors of the manufactured home. Cabanas within manufactured home parks shall conform with the following specific requirements: 1. Design and construction. A cabana shall be designed and constructed as a structurally independent structure. A cabana may be attached to a manufactured home with appropriate flashing or sealing materials to provide a weather seal. 2. Dimensions. a. The height of a cabana shall not exceed the height of the manufactured home. b. A cabana shall have a minimum ceiling height of seven feet (2134 mm) from the finished floor. If the ceiling or roof is sloped, one-half of the sloped ceiling area shall meet the minimum ceiling height. No portion of any room having a ceiling height of less than five feet (1524 mm) shall be considered as contributing to the minimum area required in this subsection. c. Habitable rooms shall be not less than seven feet (2134 mm) in any horizontal dimension. Subsection R405.1 is hereby amended to read as follows: R405.1 Concrete or masonry foundations. Drains shall be provided around concrete or masonry foundations that retain earth and enclose habitable or usable spaces located below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems or materials shall be installed at or below the top of the footing or below the bottom of the slab and shall be designed to collect in a sump and discharge by gravity and mechanical means into an approved drainage system. Gravel or crushed stone drains shall extend not less than 1 foot (305 mm) beyond the outside edge of the footing and 6 inches (152 mm) above the top of the footing and be covered with an approved filter membrane material. The top of open joints of drain tiles shall be protected with strips of building paper. Except where otherwise recommended by the drain manufacturer, perforated drains shall be surrounded with an approved filter membrane or the filter membrane shall cover the washed gravel or crushed rock covering the drain. Drainage tiles or perforated pipe shall be placed on not less than 2 inches (51 mm) of washed gravel or crushed rock not less than one sieve size larger than the tile joint opening or perforation and covered with not less than 6 inches (152 mm) of the same material. Subsection R408.4 is hereby amended to read as follows: R408.4 Access. Access shall be provided to all under-floor spaces. Access openings through the floor shall be not smaller than 22 inches by 30 inches (559 mm by 762 mm). Openings through a perimeter wall shall be not less than 16 inches by 24 inches (407 mm by 610 mm). Where any portion of the through-wall access is below grade, an areaway not less than 16 inches by 24 inches (407 mm by 610 mm) shall be provided. The bottom of the areaway shall be below the threshold of the access opening. Through wall access openings shall not be located under a door to the residence. See Section M1305.1.4 for access requirements where mechanical equipment is located under floors. A new Subsection R908.1.1 is hereby enacted to read as follows: R908.1.1 Extent of replacement. When more than one square of asphalt shingles are required to be replaced over the aggregate area of the roof and a permit is required, every slope containing damaged shingles shall be replaced in its entirety. The interface of different types of shingles shall only occur at a ridge, hip or open valley. Subsection P2603.5 is hereby amended to read as follows: P2603.5 Freezing. In localities having a winter design temperature of 32°F (0°C) or lower as shown in Table R301.2 (1) of this code, a water, soil or waste pipe shall not be installed outside of a building, in exterior walls, in attics or crawl spaces, or in any other place subjected to freezing temperature unless adequate provision is made to protect it from freezing by insulation or heat or both. Water service pipe between the tap of the main water line and the meter shall be installed not less than 48 inches (1219 mm) below finish grade. The water service piping serving the building from the meter shall be installed not less than 12 inches (305 mm) deep and not less than 6 inches (152 mm) below the frost line. Subsection P2603.5.1 is hereby repealed and reenacted to read as follows: P2603.5.1 Sewer depth. Building sewers shall be not less than 12 inches (305 mm) below grade. Subsection P2903.3.2 is hereby amended to read as follows: P2903.3.2 Maximum pressure. The maximum static water pressure shall be not greater than 80 psi (551 kPa). An approved pressure-reducing valve conforming to ASSE 1003 or CSA B356 shall be installed on the domestic water branch mains or risers at the connection to the waterservice pipe.
(Ord. No. 3136, § 19, 7-13-10; Ord. No. 3206, § 1, 8-14-12; Ord. No. 3252, § 18, 7-23-13; Ord. No. 3398, § 13, 8-23-16; Ord. No. 3538, § 14, 9-10-19; Ord. No. 3643, § 13, 2-14-23; Ord. No. 3731, § 13, 5-13-25)
Ask a question about Thornton law
Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.