For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-154 — Amendments to International Plumbing Code

Code of the City of Thornton, Colorado (Supp. No. 65: codified through Ordinance No. 3773, adopted June 9, 2026) · Thornton City Code § 10-154

Corpus is an independent public-information project, not the official City of Thornton website. Stable reference: corpuslaw.us/code/1cbe9759-169b-4fc6-921d-e3a09f0f4519

Sec. 10-154. - Amendments to International Plumbing Code.

The International Plumbing Code adopted in Section 10-153 is amended as follows, with section numbers referring to section numbers of the International Plumbing Code: Subsection [A] 101.1 is hereby amended to read as follows: [A] 101.1 Title. These regulations shall be known as the Plumbing Code of the City of Thornton, hereinafter referred to as "this code." Subsection 305.4 is hereby amended to read as follows: 305.4 Freezing. Water, soil and waste pipes shall not be installed outside of a building, in attics or crawl spaces, concealed in outside walls, or in any other place subjected to freezing temperatures unless adequate provision is made to protect such pipes from freezing by insulation or heat or both. Exterior water supply system piping between the tap of the main water line and the water meter shall be installed not less than 48 inches (1219 mm) below finished grade. The water service piping serving the building from the meter shall be installed not less than 6 inches (152 mm) below the frost line and not less than 12 inches (305 mm) below grade. Subsection 305.4.1 is hereby amended to read as follows: 305.4.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be installed not less than 12 inches (305 mm) below finished grade at the point of septic tank connection. Building sewers shall be installed not less than 12 inches (305 mm) below grade. Subsection 312.1 is hereby amended to read as follows: 312.1 Required tests. The permit holder shall make the applicable tests prescribed in Sections 312.2 through 312.10 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder and he or she shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. Plumbing system piping shall be tested with either water or air. After the plumbing fixtures have been set and their traps filled with water, the entire drainage system shall be submitted to final tests. The code official shall require the removal of any cleanouts if necessary to ascertain whether the pressure has reached all parts of the system. Table 403.1 footnotes e and g are hereby amended to read as follows: TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa(See Sections 403.1.1 and 403.2) No. | Classification | Description | Water Closets (Urinals See Section 424.2 of The International Plumbing Code) | Lavatories | Bathtubs/Showers | Drinking Fountains (See Section 410 of The International Plumbing Code) g | Other Male | Female | Male | Female 1 | Assembly | Theaters and other buildings for the performing arts and motion pictures d | 1 per 125 | 1 per 65 | 1 per 200 | — | 1 per 500 | 1 service sink Nightclubs, bars, taverns, dance halls and buildings for similar purposes d | 1 per 40 | 1 per 40 | 1 per 75 | — | 1 per 500 | 1 service sink Restaurants, banquet halls and food courts d | 1 per 75 | 1 per 75 | 1 per 200 | — | 1 per 500 | 1 service sink Casino gaming areas | 1 per 100 for the first 400 and 1 per 250 for the remainder exceeding 400 | 1 per 50 for the first 400 and 1 per 150 for the remainder exceeding 400 | 1 per 250 for the first 750 and 1 per 500 for the remainder exceeding 750 | — | 1 per 1,000 | 1 service sink Auditoriums without permanent seating, art galleries, exhibition halls, museums, lecture halls, libraries, arcades and gymnasiums d | 1 per 125 | 1 per 65 | 1 per 200 | — | 1 per 500 | 1 service sink Passenger terminals and transportation facilities d | 1 per 500 | 1 per 500 | 1 per 750 | — | 1 per 1,000 | 1 service sink Places of worship and other religious services d | 1 per 150 | 1 per 75 | 1 per 200 | — | 1 per 1,000 | 1 service sink Coliseums, arenas, skating rinks, pools and tennis courts for indoor sporting events and activities | 1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 | 1 per 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 | 1 per 200 | 1 per 150 | — | 1 per 1,000 | 1 service sink Stadiums, amusement parks, bleachers and grandstands for outdoor sporting events and activities f | 1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 | 1 per 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 | 1 per 200 | 1 per 150 | — | 1 per 1,000 | 1 service sink 2 | Business | Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, light industrial, ambulatory care and similar uses | 1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50 | 1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80 | — | 1 per 100 | 1 service sink e 3 | Educational | Educational facilities | 1 per 50 | 1 per 50 | — | 1 per 100 | 1 service sink 4 | Factory and industrial | Structures in which occupants are engaged in work fabricating, assembly or processing of products or materials | 1 per 100 | 1 per 100 | — | 1 per 400 | 1 service sink 5 | Institutional | Custodial care facilities | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink Medical care recipients in hospitals and nursing homes b | 1 per room c | 1 per room c | 1 per 15 | 1 per 100 | 1 service sink Employees in hospitals and nursing homes b | 1 per 25 | 1 per 35 | — | 1 per 100 | — Visitors in hospitals and nursing homes | 1 per 75 | 1 per 100 | — | 1 per 500 | — Prisons b | 1 per cell | 1 per cell | 1 per 15 | 1 per 100 | 1 service sink Reformatories, detention centers and correctional centers b | 1 per 15 | 1 per 15 | 1 per 15 | 1 per 100 | 1 service sink Employees in reformatories, detention centers and correctional centers b | 1 per 25 | 1 per 35 | — | 1 per 100 | — Adult day care and child day care | 1 per 15 | 1 per 15 | 1 | 1 per 100 | 1 service sink 6 | Mercantile | Retail stores, service stations, shops, salesrooms, markets and shopping centers | 1 per 500 | 1 per 750 | — | 1 per 1,000 | 1 service sink e 7 | Residential | Hotels, motels, boarding houses (transient) | 1 per sleeping unit | 1 per sleeping unit | 1 per sleeping unit | — | 1 service sink Dormitories, fraternities, sororities and boarding houses (not transient) | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink Apartment house | 1 per dwelling unit | 1 per dwelling unit | 1 per dwelling unit | — | 1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per 20 dwelling units One- and two- family dwellings and lodging houses with five or fewer guestrooms | 1 per dwelling unit | 1 per 10 | 1 per dwelling unit | — | 1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per dwelling unit Congregate living facilities with 16 or fewer persons | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink 8 | Storage | Structures for the storage of goods, warehouses, storehouses and freight depots, low and moderate hazard | 1 per 100 | 1 per 100 | — | 1 per 1,000 | 1 service sink a. The fixtures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction of the number of persons indicated. The number of occupants shall be determined by this code. b. Toilet facilities for employees shall be separate from facilities for inmates or care recipients. c. A single-occupant toilet room with one water closet and one lavatory serving not more than two adjacent patient sleeping units shall be permitted, provided that each patient sleeping unit has direct access to the toilet room and provisions for privacy for the toilet room user are provided. d. The occupant load for seasonal outdoor seating and entertainment areas shall be included when determining the minimum number of facilities required. e. For business classifications with an occupant load of 25 or fewer, and mercantile classifications with an occupant load of 42 or fewer, a service sink shall not be required. f. The required number and type of plumbing fixtures for outdoor swimming pools shall be in accordance with Section 609 of the International Swimming Pool and Spa Code. g. Drinking fountains are not required where only one toilet room is required. Subsection 410.2 is hereby amended to read as follows: 410.2 Small occupancies. Drinking fountains shall not be required where only one toilet room is required. Subsection 410.4 is hereby amended to read as follows: 410.4 Substitution. Where restaurants provide drinking water in a container free of charge, drinking fountains shall not be required in those restaurants. In other occupancies, where three or more drinking fountains are required, water dispensers shall be permitted to be substituted for not more than 50 percent of the required number of drinking fountains. Exception: Where only one drinking fountain is required by Table 403.1 a water cooler or bottled water dispenser may be substituted. Subsection 604.8 is hereby amended to read as follows: 604.8 Water-pressure reducing valve or regulator. The maximum static pressure within a building shall be 80 psi (552 kPa). An approved water-pressure reducing valve conforming to ASSE 1003 or CSA B356 with strainer shall be installed to reduce the pressure in the building water distribution piping to not greater than 80 psi (552 kPa) static.

(Ord. No. 2993, § 4, 6-5-07, eff. 7-2-07; Ord. No. 3136, § 8, 7-13-10; Ord. No. 3252, § 10, 7-23-13; Ord. No. 3398, § 7, 8-23-16; Ord. No. 3538, § 6, 9-10-19; Ord. No. 3643, § 5, 2-14-23; Ord. No. 3648, § 4, 4-11-23; Ord. No. 3731, § 6, 5-13-25)

Ask a question about Thornton law

Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.