For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19-157 — General requirements for all inspection types

Code of Ordinances, City of Boca Raton, Florida (Supp. 72 Update 2: codified through Ordinance of June 9, 2026 (online updated October 20, 2026)) · Boca Raton Code of Ordinances § 19-157

Corpus is an independent public-information project, not the official City of Boca Raton website. Stable reference: corpuslaw.us/code/4bca99ac-f7c9-4df5-ba67-39f58fa5d01e

Sec. 19-157. - General requirements for all inspection types.

(1) Approval required to proceed beyond work to be inspected. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the building official for the required inspection. The building official, upon notification, shall make the requested inspections and shall either indicate the portion of the construction that is approved as completed, or notify the permit holder wherein the same fails to comply with this building code. Any portions that do not comply with the approved construction plans shall be corrected and such portion shall not be covered or concealed until authorized by the building official. (2) Reinforcing steel and structural framing. Reinforcing steel or structural frame work of any part of any building or structure shall not be covered or concealed without first obtaining a release from the building official. Certification that field welding and structural bolted connections meet design requirements shall be submitted to the building official upon request. (3) Termites. Building components and building surroundings required to be protected from termite damage in accordance with Section 1503.7, Section 2304.12 or Section 2304.12.4, Florida Building Code, specifically required to be inspected for termites in accordance with Section 2114, Florida Building Code, or required to have chemical soil treatment in accordance with Section 1816, Florida Building Code, shall not be covered or concealed until authorized by the building official. (4) Shoring. For threshold buildings, shoring and associated formwork or falsework shall be designed and inspected by a state licensed professional engineer, employed by the permit holder, prior to any required mandatory inspections by the threshold building inspector. (5) Fire- and smoke-resistant penetrations. Protection of joints and penetrations in fire-resistance-rated assemblies, smoke barriers and smoke partitions shall not be covered or concealed until authorized by the building official.

(Ord. No. 5455, § 2, 5-22-18)

Ask a question about Boca Raton law

Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.