Sec. 19-158. - Special requirements for inspections for new threshold buildings.

These requirements also apply to any existing threshold building being renovated, remodeled, altered or repaired. (1) The city shall require a special inspector to perform structural inspections on a threshold building pursuant to a structural inspection plan prepared by the engineer or architect of record. The structural inspection plan shall be submitted to the city prior to the issuance of a building permit for the construction of a threshold building. The purpose of the structural inspection plan is to provide specific inspection procedures and schedules so that the building can be adequately inspected for compliance with the permitted documents. The special inspector may not serve as a surrogate in carrying out the responsibilities of the building official, the architect or the engineer of record. The contractor's contractual or statutory obligations are not relieved by any action of the special inspector. (2) The special inspector shall determine that a professional engineer who specializes in shoring design has inspected the shoring and reshoring for conformance with the shoring and reshoring plans submitted to the city. A fee simple title owner of a building which does not meet the minimum size, height, occupancy, occupancy classification or number-of-stories criteria which would result in classification as a threshold building under F.S. § 553.71 may designate such building as a threshold building, subject to more than the minimum number of inspections required by the building code. (3) The fee owner of a threshold building shall select and pay all costs of employing a special inspector, however, the duty of loyalty of the special inspector shall be to the city. The special inspector shall be a person certified, licensed or registered under F.S. ch. 471 as an engineer or under F.S. ch. 481 as an architect and hold the endorsement as a special threshold inspector. Any onsite representative performing threshold and/or minimum building code inspections required by the building code on behalf of the special inspector shall also be a person certified, licensed or registered under F.S. ch. 471 as an engineer, under F.S. ch. 481 as an architect or be certified as a standard building codes inspector under F.S. ch. 468, pt. XII. (4) The city shall require that, on every threshold building: (a) All plans for the building which are required to be signed and sealed by the architect or engineer of record contain a statement that, to the best of the architect's or engineer's knowledge, the plans and specifications comply with the applicable minimum building codes and the applicable fire-safety standards as determined by the local authority in accordance with this section and F.S. ch. 633. (b) The special inspector shall, upon completion of the building and prior to the issuance of a certificate of occupancy, file a signed and sealed statement with the city in substantially the following form: "To the best of my knowledge and belief, the above described construction of all structural load-bearing components complies with the permitted documents, and the shoring and reshoring conforms to the shoring and reshoring plans submitted to the City of Boca Raton." (c) Any proposal to install an alternate structural product or system to which this building code applies shall be submitted to the city for review for compliance with this building code and made part of the city's permit documents record. (d) All shoring and reshoring procedures, plans and details shall be submitted to the city for recordkeeping. Each shoring and reshoring installation shall be supervised, inspected and certified to ensure compliance with the shoring documents by the contractor. (e) No permit for construction of any threshold building shall be issued except to a licensed general contractor, as defined in F.S. § 489.105(3)(a), or to a licensed building contractor, as defined in F.S. § 489.105(3)(b), within the scope of his license. The named contractor to whom the permit is issued shall have the responsibility for supervision, direction, management and control of the construction activities on the project for which the building permit was issued. (f) The building official may allow a special inspector to conduct the minimum structural inspection of threshold buildings required by this building code and the Florida Building Code, without duplicative inspection by the city. The building official shall be responsible for ensuring that any person conducting inspections is qualified as a standard building codes inspector under F.S. ch. 468, pt. XII, or certified as a special inspector under F.S. ch. 471 or 481. Inspections of threshold buildings required by F.S. § 553.79(5) are in addition to the minimum inspections required by this building code.

(Ord. No. 5455, § 2, 5-22-18)

Ask a question about Boca Raton law

Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.