Sec. 32.212. - General sewer use requirements.
(1) Prohibited discharge standards. (a) General prohibitions. No user shall introduce or cause to be introduced into the WWF any pollutant or wastewater which causes pass through interference. These general prohibitions apply to all users of the WWF whether or not they are subject to categorical pretreatment standards or any other national, state, or local pretreatment standards or requirements. (b) Specific prohibitions. No user shall introduce or cause to be introduced into the WWF the following pollutants, substances, or wastewater: 1. Pollutants which create a fire or explosive hazard in the WWF, including, but not limited to, wastestreams with a closed-cup flashpoint of less than 140° F (60° C) using the test methods specified in 40 CFR 261.21; 2. Wastewater having a pH less than 5.5 or more than 9.5, or otherwise causing corrosive structural damage to the WWF or equipment; 3. Solid or viscous substances in amounts which will cause obstruction of the flow in the WWF resulting in interference but in no case solids greater than three-eighths of an inch or ninety-five-one-hundredths of a centimeter in any dimension. 4. Pollutants, including oxygen-demanding pollutants (BOD, etc.), released in a discharge at a flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, will cause interference with the WWF; 5. Wastewater having an average temperature greater than 122°F (50°C), at the point of connection with the city's sanitary sewer system; 6. Petroleum oil, non-biodegradable cutting oil, or products of mineral oil origin, in amounts that will cause interference or pass through; 7. Pollutants which result in the presence of toxic gases, vapors, or fumes within the WWF in a quantity that may cause acute worker health and safety problems; 8. Trucked or hauled pollutants, except at discharge points designated by the coordinator in accordance with section 32.213(4) of this division; 9. Noxious or malodorous liquids, gases, solids, or other wastewater which, either singly or by interaction with other wastes, are sufficient to create a public nuisance or a hazard to life, or to prevent entry into the sewers for maintenance or repair; 10. Wastewater which imparts color which cannot be removed by the treatment process, such as, but not limited to, dye wastes and vegetable tanning solutions, which consequently imparts color to the WRF's effluent, thereby violating the city's wastewater NPDES permit; 11. Wastewater containing any radioactive wastes or isotopes except in compliance with applicable state or federal regulations; 12. Stormwater, excluding stormwater that has been in contact with an approved industrial process, surface water, ground water, artesian well water, roof runoff, subsurface drainage, swimming pool drainage, condensate, deionized water, non-contact cooling water, and unpolluted wastewater, unless specifically authorized by the coordinator; 13. Sludges, screenings, or other residues from the pretreatment of industrial wastes; 14. Medical wastes, except as specifically authorized by the coordinator in a wastewater discharge permit; 15. Wastewater, alone or in conjunction with other sources, causing the POTW's effluent to fail a toxicity test; 16. Detergents, surface-active agents, or other substances which may cause excessive foaming in the WRF; 17. Fats, oils, or greases of animal or vegetable origin in excess of the established local limit, or in quantities which can impeded or impair flow. 18. Hazardous waste pharmaceuticals from healthcare facilities and reverse distributors. Pollutants, substances, or wastewater prohibited by this section shall not be processed or stored in such a manner that they could be discharged into the WWF. (2) National Categorical Pretreatment Standards. The categorical pretreatment standards found at 40 CFR Chapter I, Subchapter N, Parts 405-471 are hereby incorporated into this division. (a) Where a categorical pretreatment standard is expressed only in terms of either the mass or the concentration of a pollutant in wastewater, the coordinator may impose equivalent concentration or mass limits in accordance with Chapter 62-625.410(4) FAC. (b) When the limits in a categorical pretreatment standard are expressed only in terms of mass of pollutant per unit of production, the coordinator may convert the limits to equivalent limitations expressed either as mass of pollutant discharged per day or effluent concentration for purposes of calculating effluent limitations applicable to individual industrial users Chapter 62-625.410(4) FAC. (c) When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the coordinator shall impose an alternate limit using the combined wastestream formula in Chapter 62-625.410(6) FAC. Only those industrial subcategories listed in Chapters 62-625.880(1) FAC will be considered eligible for the combined wastestream formula. (d) A user may obtain a variance from a categorical pretreatment standard if the user can prove, pursuant to the procedural and substantive provisions in Chapter 62-625.700 FAC that factors relating to its discharge are fundamentally different from the factors considered by EPA when developing the categorical pretreatment standard. The user requesting variance must file a formal request to the city, along with the permit application for a wastewater discharge permit, in accordance with the procedures in section 32.215 of the division. (e) A user may obtain a net gross adjustment to a categorical standard in accordance with Chapter 62-625.820 FAC, with approval from the city. Industrial user's file must contain documentation of how equivalent limits were determined. (f) Categorical industrial user (CIU) designations and criteria. These designations and the reduction of permitting, sampling and reporting are at the discretion of the public utilities director. Regardless of designation, all CIU shall be tracked and the list of CIU shall be submitted to FDEP as part of the annual report in accordance with 62-625.600(8). 1. To qualify as a non-significant categorical industrial user (NSCIU): (a) Never discharge 100 gpd or more of total categorical wastewater discharged (no averaging). (b) Have consistently complied with all applicable pretreatment standards. (c) Never discharge any untreated concentrated wastewater. 2. To qualify as a middle tier categorical industrial user designation: (a) Discharge does not exceed 0.01 percent of the design dry weather hydraulic capacity of the WWF or 5,000 gallons per day whichever is smallest. (b) Discharge does not exceed 0.01 percent of the design dry weather organic treatment capacity of the WWF; and (c) Discharge does not exceed the maximum allowable headworks loading for any pollutant for which approved local limits were developed. (d) CIU has not been in significant non-compliance any time in the past two years. (e) Reduced reporting requirements would still result in data that is representative of the conditions occurring at the facility and in the discharge. (3) State pretreatment standards. Chapter 62-625.410 FAC identifies pretreatment standards (by reference) for industries, and is applicable in the determination of categorical industrial discharges within the city's jurisdiction. The industrial pretreatment program shall develop and implement procedures to ensure compliance, and at a minimum enable the program to: Identify and locate all possible industrial users which might be subject to the pretreatment program. 32-214(1). (a) Identify the character and volume of pollutants contributed to the WWF by the industrial users identified under (a) above, 32.214(2); 32.214(6); 32.216(1); (b) Notify industrial users identified under (a) above of applicable pretreatment standards and any applicable requirements under Parts I and IV of Chapter 403, F.S., regarding disposal of sludge. Within 30 days of approval of a list of significant industrial users, in accordance with paragraph 32.214(1)(d), notify each significant industrial user of its status as such and of all requirements applicable to it as a result of such status; (c) Receive and analyze self-monitoring reports and other notices submitted by industrial users in accordance with the self-monitoring requirements in Rule 62-625.600 FAC; (d) Randomly sample and analyze the effluent from industrial users and conduct surveillance activities in order to identify, independent of information supplied by industrial users, occasional and continuing non-compliance with pretreatment standards. Inspect and sample the effluent from each significant industrial user at least once a year, except as specified in sub-subparagraphs 1. through 3. below. 1. Where the control authority has authorized a categorical industrial user to waive sampling of a pollutant regulated by a categorical pretreatment standard in accordance with paragraph 62-625.600(4)(b), FAC, the control authority must sample for the waived pollutant(s) at least once during the term of the categorical industrial user's control mechanism. In the event that the control authority subsequently determines that a waived pollutant is present or is expected to be present in the industrial user's wastewater based on changes that occur in the user's operations, the control authority must immediately begin at least annual inspection and effluent monitoring of the user's discharge; 2. Where the control authority has determined that an industrial user meets the criteria for classification as a non-significant categorical industrial user, the control authority must evaluate, at least once per year, whether an industrial user continues to meet the criteria in paragraph 62-625.200(25)(c), FAC; or 3. In the case of industrial users subject to reduced reporting requirements under paragraph 62-625.600(4)(d), FAC, the control authority must randomly sample and analyze the effluent from industrial users and conduct inspections at least once every two years. If the industrial user no longer meets the conditions for reduced reporting in paragraph 62-625.600(4)(d), FAC, the control authority must immediately begin sampling and inspecting the industrial user at least once a year; (e) Evaluate significant industrial users plan to control slug discharges 32.213(3). (f) Investigate instances of non-compliance with pretreatment standards and requirements, as indicated in the reports and notices required under Rule 62-625.600, FAC, or indicated by analysis, inspection, and surveillance activities described in subparagraph (d) above. (4) Requirements for dental facilities that remove or place amalgam fillings. (a) Definitions. For the purposes of this subsection (4) the following words and phrases shall be as defined herein. 1. Amalgam separator. A device that employs filtration, settlement, centrifugation, or ion exchange to remove amalgam and its metal constituents from a dental office vacuum system before it discharges to the sewer. 2. Amalgam waste. Non-contact amalgam (amalgam scrap that has not been in contact with the patient); contact amalgam (including, but not limited to, extracted teeth containing amalgam); amalgam sludge captured by chairside traps, vacuum pump filters, screens, and other amalgam trapping devices; used amalgam capsules; and leaking or unusable amalgam capsules. 3. ANSI/ADA Standard No. 108. The American National Standards Institute and American Dentistry association standard for amalgam separators. 4. Existing source. Any facility subject to this subsection (4) whose first discharge to the sewer collection system occurred on or before July 14, 2017. 5. ISO 11143. The International Organization for Standardization's standard for amalgam separators. 6. New Source. Any facility subject to this subsection (4) whose first discharge to the sewer system occurs after July 14, 2017 and must comply immediately upon commencement of discharge. (b) All owners and operators of dental facilities that remove or place amalgam fillings shall comply with the following reporting and waste management practices: 1. For existing sources, the one-time compliance report is due no later than October 12, 2020 or no later than 90 days after transfer of ownership. 2. For new sources, the one-time compliance report is due within 90 days of the start of discharge to the sewer collection system. 3. No person shall rinse chairside traps, vacuum screens, or amalgam separators equipment in a sink or other connection to the sanitary sewer. 4. Owners and operators of dental facilities shall ensure that all staff members who handle amalgam waste are trained in the proper handling, management and disposal of mercury-containing material and fixer-containing solutions and shall maintain training records that shall be available for inspection by the director or designee during normal business hours. 5. Amalgam waste shall be stored and managed in accordance with the instructions of the recycler or hauler of such materials. 6. Bleach and other chlorine-containing disinfectants shall not be used to disinfect the vacuum line system. 7. The use of bulk mercury is prohibited. Only pre-capsulated dental amalgam is permitted. (c) All owners and operators of dental vacuum suction systems, except as set forth in subsections (d) and (e) of this subsection (4), shall comply with the following: 1. An ISO 11143 or ANSI/ADA Standard No. 108 certified amalgam separator or equivalent device shall be installed for each dental vacuum suction system on or before July 14, 2020; provided, however, that all dental facilities that are newly constructed on and after the effective date of the ordinance from which this subsection derives shall include an installed ISO 11143 or ANSI/ADA Standard No. 108 certified amalgam separator device. The installed device must be ISO 11143 or ANSI/ADA Standard No. 108 certified as capable of removing a minimum of 95 percent of amalgam. The amalgam separator system shall be certified at flow rates comparable to the flow rate of the actual vacuum suction system operation. Neither the separator device nor the related plumbing shall include an automatic flow bypass. For facilities that require an amalgam separator that exceeds the practical capacity of ISO 11143 test methodology, a non-certified separator will be accepted, provided that smaller units from the same manufacturer and of the same technology are ISO-certified. 2. Proof of certification and installation records shall be submitted to the director or designee within 30 days of installation. 3. Amalgam separators shall be maintained in accordance with manufacturer recommendations. Installation, certification, and maintenance records shall be available for immediate inspection upon request therefor by the director or designee during normal business hours. Records shall be maintained for a minimum of three years. (d) Facilities with vacuum suction systems that meet all the following conditions may apply to the director for an exemption to the requirements of subsection (c) of this section: 1. The system is a dry vacuum pump system with an air-water separator. 2. The sedimentation tank is non-bottom draining, with the drain above the anticipated maximum level of accumulated sludge. 3. Evidence of regular pump outs by a licensed hauler (a minimum of once a year, or more often if either directed by the manufacturer or necessary to keep solids from exiting through the drain) is maintained and open to inspection by the director or designee during normal business hours. 4. The system has no direct discharge pipe to the sewer on the bottom of the sedimentation tank. An owner or operator whose facility meets the above conditions 1. through 4. may apply for this exemption by written letter to the director. The director or designee will review the system and, if the exemption is approved, shall provide a written letter of exemption. An exemption obtained pursuant to this subsection (d) shall expire upon installation of a new vacuum system. Upon expiration of the exemption, the facility shall comply with subsection (c) of this subsection (4) before commencing further operation. (e) Dental dischargers that exclusively practice one or more of the following specialties are not subject to the requirements of this section: (1) orthodontics; (2) periodontics; (3) oral and maxillofacial surgery; (4) radiology; (5) oral pathology or oral medicine; (6) endodontistry and prosthodontistry. (f) Dental practices that do not place dental amalgam, and do not remove amalgam except in limited emergency or unplanned, unanticipated circumstances, are exempt from the requirements of this part, provided the dental practice: 1. Submits the following statement to the city, signed by a responsible corporate officer, general partner, proprietor, or a duly authorized representative by the applicable compliance deadline identified in this subsection (b): "This facility is a dental discharger subject to this rule and does not place or remove dental amalgam except in limited emergency or unplanned, unanticipated circumstances. I am a responsible corporate officer, a general partner or proprietor (if the facility is a partnership or sole proprietorship), or a duly authorized representative in accordance with the requirements of 40 CFR § 403.12(I) of the above named dental facility, and certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations."; 2. Removes dental amalgam for limited emergency or unplanned, unanticipated circumstances; and 3. The dental practice notifies the city of any changes affecting the applicability of this certification. (g) Disposal of hauled waste from dental facilities to the sanitary sewer is prohibited. (5) Local limits. Local limits shall be established, using standard procedures, calculations and methods acceptable to FDEP, to protect against pass through and interference. A "plan of study" must be submitted to the department prior to beginning sampling necessary to determine local limits. No industrial user shall discharge process wastewater, individual regulated wastestreams, unregulated wastestreams, or dilute wastestreams in excess of the concentrations set forth by the director, or his/her designee. Local limits shall be included as permit conditions and attached to each significant industrial user (SIU) permit issued. (a) The established local limits are subject to change and shall be modified as needed based on regulatory requirements and standards, WWF operation, performance and processes, the industrial user base, potable water quality and domestic wastewater characteristics. Modifications to the established local limits must be reviewed and approved by FDEP prior to implementation. Implementation of the modified limits shall be accomplished through the development and issuance of an addendum to each SIU permit. (b) The established local limits apply at the point where the wastewater is discharged to the WWF. All concentrations for metallic substances are for "total" metal unless indicated otherwise. The coordinator may impose mass limitations in addition to, or in place of, the concentration based limitations set forth by the director, or his/her designee. (c) The pretreatment program may develop best management practices (BMPs) these may be implemented by ordinance or in individual wastewater discharge permits or general permits these BMPs shall be considered local limits and pretreatment standards, section 32.212(1), and shall be enforced as such. (6) The city's right of revision. The city reserves the right to establish, by ordinance, or by the director, individual wastewater discharge permits, or general permits, more stringent standards or requirements for discharges to the WWF consistent with the purpose of this ordinance. (7) Dilution. Dilution prohibited as substitute for treatment. Except where expressly authorized to do so by an applicable pretreatment standard or requirement. No user shall ever increase the use of process water, or in any way attempt to dilute a discharge, as a partial or complete substitute for adequate treatment to achieve compliance with a discharge limitation unless expressly authorized by an applicable pretreatment standard or requirement. The coordinator may impose mass limitations on users who are using dilution to meet applicable pretreatment standards or requirements, or in other cases when the imposition of mass limitations is appropriate.
(Ord. No. 6393-99, § 1, 8-5-99; Ord. No. 6828-01, § 2, 8-16-01; Ord. No. 8322-13, § 2, 2-21-13; Ord. No. 9389-20, § 2, 5-7-20)
Ask a question about Clearwater law
Corpus searches the Clearwater sections it holds and shows the ones that match, with their citations. Free, no sign-in.