For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 27-180.1 — Same—Prohibited substances

Code of Ordinances, City of Gainesville, Florida (Supp. No. 64, Update 1: codified through Ordinance No. 2024-740, adopted November 6, 2025) · Gainesville City Code § 27-180.1

Corpus is an independent public-information project, not the official City of Gainesville website. Stable reference: corpuslaw.us/code/bc3c5bec-29e8-4f85-a4f8-3e8d6161e452

Sec. 27-180.1. - Same—Prohibited substances.

(a) No user shall introduce or cause to be introduced into the wastewater system any pollutant or wastewater, which either singly or by interaction with other pollutants causes pass through or interference. This general prohibition applies to all users of the wastewater system whether or not they are subject to categorical pretreatment standards or any other federal, state, or local pretreatment standards or requirements. (b) It shall be unlawful for any person willfully or with culpable negligence to discharge or cause to be discharged into the wastewater system of the city any substance which: (1) Is harmful to the wastewater system, or is hazardous to the wastewater system because it contains flammable or explosive liquids, solids or gases, which by reason of their nature or quantity are, or may be, sufficient, either alone or by interaction with other substances, to cause fire or explosion or be injurious in any other way to the wastewater system or to the operation of the wastewater system. No substance may be discharged with a closed cup flashpoint of less than 60° C (140° F) using test methods specified in 40 CFR 261.21. At no time shall two successive readings on an explosion hazard meter, at the point of discharge into the system (or at any point in the system) be more than five percent, nor any single reading over ten percent, of the lower explosive limit (LEL) of the meter. Such materials shall include, but are not limited to, gasoline, kerosene, naphtha, benzene, toluene, xylene, ethers, alcohols, ketones, aldehydes, peroxides, chlorates, perchlorates, bromates, carbides, hydrides and sulfides and any other substances which the city determines to be a fire hazard, health hazard or a hazard to the system. (2) Has a temperature which would have adverse effects on the wastewater system. In no case shall discharges cause the temperature of influent to the wastewater treatment plant to exceed 40° C (104° F). (3) May cause stoppages in the wastewater system because of size, quantity, volume or any other characteristic. Solid or viscous substances which may cause obstruction to the flow in the sewer or other interference with the operation of the wastewater treatment facilities shall not be discharged into the wastewater system. (4) Has corrosive properties capable of causing damage or hazard to structures, equipment and/or personnel of the wastewater system. (5) May cause the wastewater system's effluent or any other product of the wastewater system, such as residues, sludges or scums to be unsuitable for reclamation and reuse, or to interfere with the reclamation process. (6) Contains any pollutant, including oxygen demanding pollutants (BOD, etc.), released at a flow rate and/or pollutant concentration which either singly or by interaction with other pollutants, will cause interference or pass through in the wastewater system. No user shall discharge flow at a rate that will be disruptive to the wastewater system or cause interference or pass through in the wastewater system. (7) Results in the presence of toxic gases, vapors, or fumes in any part of the wastewater system in a quantity that may cause acute worker health and safety problems. (8) Contains pollutants in sufficient quantity, either singly or by interaction with other pollutants, which constitute a hazard to humans or animals, or create a toxic effect in the receiving waters of the wastewater system. (9) Contains waste exceeding the local discharge limit of any pollutant for which a limit has been established by the general manager for utilities or his/her designee using standard procedures, calculations and methods acceptable to the Florida Department of Environmental Protection (FDEP) to protect against pass through, interference, protection of wastewater system employees, and adverse effects on wastewater biosolids disposal. Such limits shall be included as permit conditions and attached to each industrial wastewater discharge permit issued. The established local discharge limits, incorporated by reference herein, are subject to change and may be modified as needed based on regulatory requirements and standards, wastewater system operation, performance and processes, the industrial user base, potable water quality and domestic wastewater characteristics. Modifications to the established local discharge limits must be reviewed and approved by FDEP prior to implementation. Implementation shall be effective 30 days from notice of acceptance of the modified discharge limits by FDEP. Permitted significant industrial users shall also be issued an addendum to their wastewater discharge permit containing the revised local discharge limits. A copy of the approved local discharge limits shall be kept on file in the office of the general manager for utilities or his/her designee and made available on request. (10) Discharge limits for sulfate, sulfide, and organic pollutants shall be determined by the general manager for utilities or his/her designee with considerations for acceptable worker exposure levels or prevention of damage, interference or pass through in the wastewater system, whichever provides the lower discharge limit. (11) Local discharge limits shall apply at the point where the wastewater is discharged to the wastewater system. All concentrations for metallic substances are for "total" metal. (c) No user shall ever increase the use of process water, or, in any way, attempt to dilute a discharge as a partial or complete substitute for adequate treatment, to achieve compliance with a local discharge limit, prohibited discharge standard, or categorical pretreatment standard. The general manager for utilities or his/her designee may impose mass limitations when appropriate. (d) No user shall discharge petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin in amounts that will cause interference or pass through in the wastewater system. (e) No user shall discharge trucked or hauled wastes to the wastewater system except at points designated by special agreement with the city. (f) The city may establish, by ordinance or in individual wastewater discharge permits, more stringent standards or requirements or standards for substances not contained in this section for discharges to the wastewater system consistent with the purpose of this division. (g) The National Categorical Pretreatment Standards found at 40 CFR Chapter I, Subpart N and Chapter 62-660, F.A.C., as may be amended from time to time, are hereby incorporated by reference. (h) When wastewater subject to a National Categorical Pretreatment Standard is mixed with wastewater not regulated by the same standard, the general manager for utilities or his/her designee shall impose an alternate limit in accordance with Rule 62-625.410 F.A.C.

(Ord. No. 980894, § 3, 6-14-99; Ord. No. 060457, § 2, 10-23-06; Ord. No. 120211, § 2, 9-20-12)

Ask a question about Gainesville law

Corpus searches the Gainesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.