§ 21-267 — Definitions
Code of the City of Miramar, Florida (Supp. No. 105: codified through Ordinance No. 26-10, adopted July 8, 2026) · Miramar City Code § 21-267
Corpus is an independent public-information project, not the official City of Miramar website. Stable reference: corpuslaw.us/code/8b057fde-321f-4b73-8592-c02ee56c8e3d
Sec. 21-267. - Definitions.
[For the purposes of this article, certain terms shall have the meanings ascribed to them in this section, unless the context clearly indicates otherwise.] Air gap separation shall mean the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of such vessel. Approved shall mean accepted by the utilities or building department as meeting an applicable specification stated or cited in this article, and is suitable for the proposed use. Auxiliary water supply shall mean any water supply on or available to the premises other than the purveyors approved public water supply. Auxiliary waters may include water from another purveyors potable water supply or any natural source such as well, river, stream, canal, used water, reuse water, industrial fluids, etc. These waters may be polluted, contaminated or objectionable and constitute an unacceptable water source over which the water purveyor does not have sanitary control. Backflow shall mean the undesirable reversal of flow of water or other substances through a cross-connection and into the piping of a public water system or consumers water system. Backflow prevention assembly approved shall mean an assembly used for containment and/or isolation purposes that has been investigated and approved by the public works/utilities department and has been shown to meet the design and performance standards of the American Society of Sanitary Engineers (ASSE), the American Water Works Association (AWWA), and the Foundation for Cross Connection Control and Hydraulic Research of the University of Southern California (FCCC). Backflow prevention device shall mean any assembly, device or other means designed to prevent flow reversal through pipes or valves. Backpressure shall mean a pressure higher than the supply pressure caused by a pump, elevated tank, boiler, cooling tower, or any other means that may cause backflow. Back-siphonage shall mean backflow caused by negative or reduced pressure in the piped water system. Building official shall mean the person designated as the principal enforcing officer of the South Florida Building Code within the City of Miramar. Certified backflow tester/technician shall mean a person, who is certified to make competent tests, or to repair, overhaul and make reports on backflow prevention assemblies. Such person shall be knowledgeable of applicable laws, rules, and regulations, shall be a licensed plumber or have at least two (2) years of experience under a plumber and be employed by a Florida State licensed plumber or plumbing contractor, or have equivalent qualifications acceptable to the City of Miramar Public Works Utilities Department, and must hold a certificate of completion from an approved training program in the testing and repair of backflow prevention assemblies as listed: AWWA American Water Works Association FWPCOA Florida Water and Pollution Control Operators Association ASSE American Society of Sanitary Engineers NETTI National Environmental Technology Training Institute FCCCHR Foundation for Cross Connection Control and Hydraulic Research TREEO Training Research and Education for Environmental Occupations ICCC Institute for Cross Connection Control All certified backflow prevention assembly testers must become re-certified every two (2) years through an approved backflow prevention certification program. Consumer is a person or facility receiving service from an approved water system. Consumer's dual water system shall mean the combination of the consumer's potable and reclaimed water systems that services the consumer's property. Consumers potable water system shall mean that portion of the privately owned potable water system lying between the point of delivery and point of use and/or isolation protection. This system will include all pipes, conduits, tanks, receptacles, fixtures, equipment and appurtenances used to produce, convey, store or use potable water. Consumer's reclaimed water system shall mean that portion of the privately owned reclaimed water system lying between the point of delivery and point of use and/or isolation protection. This system will include all pipes, conduits, tanks, receptacles, fixtures, equipment and appurtenances used to produce, convey, store or use reclaimed water. Contamination shall mean an impairment of the quality of the water, which creates a potential or actual hazard to the public health through the introduction of hazardous or toxic substances, or through the spread of disease by sewage, industrial fluids or water. Cross-connection shall mean any temporary or permanent connection between an approved public dual water system or consumer's dual water system and any other source through which it is possible to introduce into any part of the public dual water system any substance other than approved water. By-pass arrangements, jumper connections, removable sections, swivel or changeover devices, and any other temporary or permanent devices through which, or because of which, backflow could occur are considered cross-connections. Cross connection control shall mean a connection between a public water system and a non-approved water source with an approved backflow prevention assembly properly installed that will continuously afford the protection commensurate with the degree of hazard. Customer shall mean the person, firm, corporation or other legal entity whose name or names appear on billing for a water service connection from the City of Miramar. Degree of hazard shall mean the term derived from an evaluation of the potential risk to public health and the adverse effect of the hazard upon the approved water system. (1) Hazard, health shall mean an actual or potential threat of contamination of a physical, hazardous or toxic nature to the public or consumer's approved water system to such a degree or intensity that there would be a danger to health. (2) Hazard, non-health shall mean an actual or potential threat to the quality of the public or consumer's approved water system. A non-health hazard is one that, if introduced into the public water supply system could be a nuisance to water consumers but would not adversely effect human health. (3) Hazard, plumbing shall mean a plumbing-type cross connection in a consumer's approved water system that has not been properly protected by a vacuum breaker, air gap separation, or backflow prevention device. (4) Hazard, pollution shall mean an actual or potential threat to the physical properties of the dual water system or to the potability of the public or the consumers potable water system which could constitute a nuisance or be aesthetically objectionable or could cause minor damage to the system or its appurtenances, but would not be dangerous to human health. (5) Hazard, system shall mean an actual or potential threat of severe damage to the physical properties of the public dual water system or the consumer's dual water system or of a pollutant or contaminant which would have a protracted effect on the quality of the approved water in the system. Double check-detector assembly shall mean a specially designed assembly composed of a line-size approved double check valve assembly with a specific bypass water meter and a meter-sized approved double check valve assembly. The meter shall register (in U.S. gallons) accurately for only very low rates of flow and shall show a registration for all rates of flow. This assembly shall only be used to protect against a non-health hazard (i.e., pollutant). Double check valve assembly shall mean a device composed of two single, independently acting check valves, including tightly closing shut-off valves located at each end of the device, plus properly located test cocks for the testing of each check valve. This assembly shall only be used to protect against a non-health hazard (i.e. pollutant). Dual check valve device shall mean a compact unit manufactured with two independent spring-action check valves to prevent backflow. This device shall be used only on residential property to protect against a pollution hazard. Dual water system shall mean one set of pipes for potable water and another set for reclaimed water. Industrial fluids system shall mean any system containing a fluid or solution which may be chemically, biologically, or otherwise contaminated or polluted in a form or concentration such as would constitute a health, system, or non-health hazard if introduced into an approved water supply. Isolation shall mean the act of confining a localized hazard within a consumer's water system by installing approved backflow prevention assemblies. Owner shall mean the person, firm, corporation or other legal entity that holds title to a property or premises. Point of delivery shall generally be at the property line of the customer adjacent to the public street where mains are typically located or at a point at the customer's property where the meter is located. The customer shall be responsible for all water piping and control devices located on the customer's side of the point of delivery, except in those cases as determined by the director of public works/utilities. Potable water shall mean any water which, according to recognized standards is safe for human consumption. Pollution shall mean the impairment of the quality of the water to a degree which does not create an actual hazard to public health, but which does adversely and unreasonably affect the aesthetic qualities of such waters for domestic use. Pressure vacuum breaker shall mean an assembly consisting of an independently operating internally loaded check valve, an independently operating loaded air-inlet valve located on the discharge side of the check valve, with test cock and shut-off valves at each end of the assembly. This assembly is designed to protect against a health hazard (i.e. contaminant) under a back siphonage condition only. Public potable water system shall mean any publicly or privately owned water system operated as a public utility under a current Florida State Department of Health and Rehabilitative Services Permit to supply water for public consumption or use. This system will include all sources, facilities and appurtenances between the source and the point of delivery such as valves, pumps, pipes, conduits, tanks, receptacles, fixtures, equipment, and appurtenances used to produce, convey, treat or store potable water for public consumption or use. Purveyor, water shall mean the City of Miramar Utilities Department. Reclaimed water shall mean water that has been previously used and has been reclaimed through advanced treatment processes at the City of Miramar's Wastewater Reclamation Facility to produce high quality non-potable water. Reclaimed water is not suitable for human consumption. Reduced pressure principal assembly shall mean any assembly of two independently operating approved check valves with an hydraulically operating, mechanically independent pressure differential relief valve between the two check valves, tightly closing shut-off valves on either side of the check valves, plus properly located test cocks for the testing of the check and relief valves. This assembly is designed to protect against a health hazard (i.e., contaminant). Retrofit shall mean any work or modification to an existing facility or device. Service connections shall mean the terminal end of a service connection from any part of the public dual water system. Service connection shall also include connections from a fire hydrant and all other temporary or emergency connections from the utility system. Water, non-potable shall mean water which is not safe for human consumption or which is of questionable potability. Water, potable shall mean any water which, according to recognized standards, is safe for human consumption. Water used shall mean any water supplied by a water purveyor from a public potable water system to a consumers water system after it has passed through the point of delivery and is no longer under the sanitary control of the water purveyor.
(Ord. No. 98-23, § 4, 3-18-98; Ord. No. 00-20, § 2, 1-19-00)
Ask a question about Miramar law
Corpus searches the Miramar sections it holds and shows the ones that match, with their citations. Free, no sign-in.
