Sec. 21-272. - Backflow prevention device.

(a) An approved backflow prevention device shall be installed, at the customers expense, on each service line to a customers water system, no less than twelve (12) inches and not more than three (3) feet from the point of delivery unless approved otherwise by the plumbing official or director of public works/utilities. In all cases, the backflow shall be the first branch line leading off the service line, wherever the following conditions exist: (1) In the case of premises having an auxiliary water supply, the public water system shall be protected against backflow from the premises by installing a backflow prevention device in the service line appropriate to the degree of hazard. (2) In the case of premises upon which any industrial fluids or any other objectionable substance is handled in such a fashion as to create an actual or potential hazard to the public water system, the public system shall be protected against backflow from the premises by installing a backflow prevention device in the service line appropriate to the degree of hazard. This shall include the handling of process waters, reuse water, and waters originating from the utility system which have been subject to deterioration in quality. (3) In the case of premises having internal cross connections that cannot be permanently corrected and controlled, intricate plumbing and piping arrangements, or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross connections exist, the public water system shall be protected against backflow from the premises by installing a reduced pressure principle backflow prevention assembly in the service line. (b) The type of protective device required shall depend upon the degree of hazard which exists, as follows: (1) In the case of any premises where there is an auxiliary water supply, the public water system shall be protected by an approved air-gap separation or an approved reduced pressure principle backflow prevention device. (2) In the case of any premises where there is water or some substance that would be objectionable but not hazardous to health if introduced into the public water system, the public water system shall be protected by an approved double check valve assembly. (3) In the case of any premises where there is any material dangerous to health which is handled in such a fashion as to create an actual or potential hazard to the public water system, the public water system shall be protected by an approved air-gap separation or an approved reduced pressure principle backflow prevention device. Examples of premises where these conditions may exist include wastewater treatment plants, wastewater pumping stations, wastewater reuse pumping stations, chemical manufacturing plants, hospitals, mortuaries, and metal plating plants. (4) In the case of any premises where there are cross connections that are not controlled, either actual or potential, the public water system shall be protected by an approved air-gap separation or an approved reduced pressure principle backflow prevention device at the service connection. (5) In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete in-plant cross connection survey, the public water system shall be protected against backflow or back-siphonage from the premises by the installation of a backflow prevention device in the service line. In this case, maximum protection will be required, that is, an approved air-gap separator or reduced pressure principle backflow assembly. (6) In the case of any premises where there is reclaimed water service for irrigation, there shall be no physical connection between the reclaimed water system and the customer's potable water system which is served by a public potable water system. Where such connections are found, disconnection will be made, and the public potable water system shall be protected against the possibility of future reconnection by a reduced pressure principle backflow assembly. (c) A waiver of the requirements in paragraph (a) above is hereby granted in each case where the owner maintains documentation showing that compliance with paragraph (a) will adversely affect the operation of a pre-existent fire protection system. Also, a waiver of the requirements in paragraph (a) is hereby granted in each case where the owner maintains documentation showing all of the following: (1) The potable water system on the premises supplies water only for ordinary domestic type uses (i.e. toilet flushing, hand washing or bathing, cooking or dish washing, or lawn or garden watering) and does not supply water to any irrigation piping system, fire protection system cooling water system, space heating hot water or steam boiler, single-wall heat exchanger, double-wall heat exchanger without leak detection capability, or water loading station. (2) The premises are subject to the provisions of the South Florida Building Code, and the potable water system on the premises conforms with the South Florida Building Code, Section 4620. (3) The premises does not have multiple interconnected water service connections and does not have any auxiliary water system, reclaimed water system, wastewater pump unless the premises is a non-industrial premises with just a submersible wastewater pump, or multi-story building with four or more stories above ground. (4) No chemical except those chemicals that conform with the standards in Rule 62-555.320(3) F.A.C. is added to the potable water system on the premises. (d) The following types of facilities or services have been identified by the public works/utilities department as having a potential for backflow of non-potable water into the public water supply system. Therefore, an approved backflow prevention assembly will be required on all such services according to the degree of hazard present. Other types of facilities or services not listed below may also be required to install approved backflow prevention assemblies if determined necessary by the public works/utilities director. As a minimum requirement, all commercial services and multi-family units will be required to install a double check valve assembly, unless otherwise listed below. (1) Automotive services stations, dealerships, etc. a. No health hazard: DCVA b. Health hazard: RP (2) Automotive plants: RP (3) Auxiliary water systems: a. Approved public/private water supply: DCVA b. Unapproved public private water supply: AG c. Used water and industrial fluids: RP (4) Bakeries: a. No health hazard: DCVA b. Health hazard: RP (5) Beauty shops/barber shops: a. No health hazard: DCVA b. Health hazard: RP (6) Beverage bottling plants: RP (7) Breweries: RP (8) Buildings - Hotels, apartment houses, public and private buildings, or other structures having unprotected cross connections: a. (Under five (5) stories) No health hazard: DCVA b. (Under five (5) stories) Health hazard: RP c. (Over five (5) stories) All: RP (9) Canneries, packing houses, and rendering plants: RP (10) Chemical plants - Manufacturing, processing, compounding or treatment: RP (11) Chemically contaminated water systems: RP (12) Commercial car-wash facilities: RP (13) Commercial greenhouses: RP (14) Commercial sales establishments (department stores, malls, etc.) a. No health hazard: DCVA b. Health hazard: RP (15) Concrete/asphalt plants: RP (16) Dairies and cold storage plants: RP (17) Dye works: RP (18) Film laboratories RP (19) Fire systems: a. Systems three-fourths (¾) inch to two (2) inch 1. No health hazard: DCDA 2. Health hazard: (booster pumps, foam, antifreeze solution, etc): RP b. Systems two and one-half (2½) inch to ten (10) inch or larger 1. No health hazard DCDA 2. Health hazard: (booster pumps, foam, antifreeze solution, etc): RPDA (20) Hospitals, medical buildings, sanitariums, morgues, mortuaries, autopsy facilities, nursing and convalescent homes, medical clinics, and veterinary hospitals: RP (21) Industrial facilities: a. No health hazard: DCVA b. Heath hazard: RP (22) Laundries: a. No health hazard: DCVA b. Health hazard: (i.e., Dry Cleaners): RP (23) Lawn irrigation systems (splits taps): a. No health hazard: DCVA - (Single Tap) PVB b. Health hazard: (booster pumps, chemical systems): RP (24) Metal manufacturing, cleaning, processing, and fabricating plants: RP (25) Mobile home parks: a. No health hazard: DCVA b. Health hazard: RP (26) Oil and gas production, storage or transmission properties: RP (27) Paper and paper products plants: RP (28) Pest control (exterminating and fumigating): RP (29) Plating plants: RP (30) Power plants: RP (31) Radioactive materials or substances, plants or facilities handling: RP (32) Restaurants: a. No health hazard: DCVA b. Health hazard: RP (33) Restricted, classified, or other closed facilities: RP (34) Rubber plants (natural or synthetic): RP (35) Sand and gravel plants: RP (36) Schools and colleges: RP (37) Sewage and storm drain facilities: RP (38) Single-family residential unit: DCVA (39) Swimming pools: RP (40) Waterfront facilities and industries: RP All assembles and installations shall be subject to inspection and approval by the appropriate city officials. Legend RP - Reduced pressure principle assembly DCVA - Double check valve assembly DCDA - Double check detector assembly AG - Air gap PVB - Pressure vacuum breaker RPDA - Reduced pressure detector assembly

(Ord. No. 98-23, § 9, 3-18-98; Ord. No. 00-20, § 2, 1-19-00)

Ask a question about Miramar law

Corpus searches the Miramar sections it holds and shows the ones that match, with their citations. Free, no sign-in.