Sec. 21-274. - Installation.

(a) The city shall install all dual check valve devices on existing single-family dwelling units which require backflow protection as required by this article, section 21-272(2). (b) The fee for installation and initial testing of dual check valve devices on existing single-family dwelling units shall be set by resolution of the city commission. (c) All installations of dual check valve devices on new, single-family dwelling units shall comply with the permit and fee requirements of the building department as established by this article. (d) If the backflow preventer is on the customer's side of the property line, there shall be no takeoffs connected to the water service pipe between the property line and the backflow presenter. (e) If the backflow is on the customer's side of the property line and there exists an air gap, the water service pipe between the property line and the air gap must be visible. No bypass piping shall be installed around any backflow preventer unless the bypass piping is equipped with a backflow preventer of the same type as that which is being bypassed. (f) Each air gap, reduced pressure, or pressure vacuum breaker shall be installed in such a manner that it is not subject to flooding by a ten-year storm, or wherever practical, a one hundred-year storm. (g) Each reduced pressure, pressure vacuum breaker, double check, or residential dual check shall be installed with adequate space to facilitate testing, if applicable, and maintenance. (h) Each reduced pressure, double check, or residential dual check shall be installed in a horizontal position unless it is a make, model, and size that is specifically designed and approved for such positions. Each pressure vacuum breaker shall be installed in a vertical position unless it is a make, model, and size that is specifically designed and approved for the intended position. (i) Each reduced pressure device shall be installed with an air gap between the reduced pressure devices relief valve port and the ground or floor. (j) Reduced pressure devices (RP's) shall not be installed in pits that are entirely below ground level. If an RP is installed in a semi-buried pit or in an enclosure, the pit or enclosure shall have an above ground drain opening that discharges to a well drained area and that is sized to accommodate the maximum discharge rate through the RP's relief valve. Furthermore, there shall be an air gap between the RP's relief valve port and the maximum flood level expected in the pit or enclosure as a result of discharge through the RP's relief valve. (k) If an RP is installed inside a building, the building shall conform to the South Florida Building Code. (l) Each pressure vacuum breaker (PVB) shall be installed with its check valve at least twelve (12) inches above all down stream piping and water outlets. Each PVB shall be installed in a location where drainage is adequate to accommodate spillage through the PVB'S air inlet valve. (m) If a residential dual check (RDC) is installed below ground level, adequate drainage shall be provided to maintain a normally dry location. If a RDC is installed in a location susceptible to flooding, the RDC's test cocks shall be plugged. (n) Before installing a backflow preventer at a service connection in accordance with this article, the consumer shall, if deemed appropriate by the director of public works/utilities, conduct a thorough hydraulic analysis of any pre-existent fire protection system that is downstream from the backflow preventer, and notify the public works/utilities department if the operation of such fire protection system will be adversely affected by the backflow preventer. Further, the customer shall install a device for the control of thermal expansion in the consumer's potable water system if said system includes a water heater and will be made a closed-loop system by the backflow preventer. (o) The customers backflow preventer, if applicable, shall be tested immediately after being installed or repaired by a certified backflow tester/technician and provide a written report to the public works/utilities department of the test results within 3 days of the test.

(Ord. No. 98-23, § 11, 3-18-98)

Ask a question about Miramar law

Corpus searches the Miramar sections it holds and shows the ones that match, with their citations. Free, no sign-in.