Sec. 21-273. - Inspections, testing and recertifications.
(a) It shall be the duty of the customer at any premises where backflow prevention devices are installed to have certified inspections and recertification tests made at least once per year. Single-family dwelling units with dual check devices are not required to comply with this section. In those instances where the plumbing official or the director of public works/utilities deems the hazard to be great enough, he/she may require certified inspections at more frequent intervals. Inspections and recertification tests shall be at the expense of the customer and shall be performed by a certified backflow tester/technician approved by the director of public works/utilities or his/her designee. Backflow prevention devices shall be repaired, overhauled or replaced at the expense of the customer whenever they are found to be defective and the records of such tests shall be made available to the utilities department. The customer shall inform the utilities department of any proposed or modified cross connections and also any existing cross connections of which the customer is aware of but has not been found by the utilities department. The customer shall not install a bypass around any backflow prevention device unless there is a backflow prevention device of the same type on the bypass. Customers who cannot shut down operation for testing or repair of a backflow prevention device must supply additional devices necessary to allow testing or repair to take place. (b) A plumbing permit must be obtained from the building department for all new installations, retrofits and alterations in accordance with this article. The customer shall be responsible for having a certified backflow tester/technician conduct an annual recertification and inspection of his/her backflow prevention device. Should the customer fail to do so, the public works/utilities department personnel shall perform the required recertification and inspections and the customer shall reimburse the department for the cost it incurs. Copies of all tests and repairs shall be sent to the public works/utilities department on a form provided by the public works/utilities department. (c) The city shall have the authority and the responsibility to conduct an aggressive backflow program. Tests results of these inspections shall be maintained by the city for a period of seven (7) years. (d) All presently installed backflow prevention devices which do not meet the requirements of this section but were approved devices for the purposes described herein at the time of installation and which have been properly maintained shall, except for the inspection maintenance requirements, be excluded from the requirements of these rules, so long as these backflow prevention devices will protect the public potable water supply system in accordance with the Florida Administrative Code, Chapter 62-550 and 62-555. Whenever the existing device is moved from the present location or requires more than minimum maintenance, or when the director of public works/utilities finds that the maintenance constitutes a hazard to health, the unit shall be replaced by a backflow prevention device meeting the requirements of this article. Further, the backflow prevention device must be reinstalled if or when any of the following conditions apply or occur: (1) The backflow preventer is installed in such a manner that it cannot be tested, if applicable, or maintained. (2) The backflow preventer is an RP, PVB, or AG and is installed in such a manner that the PVB's air inlet port, the RP's relief valve port, or the supply pipe outlet at the AG could be submerged by a ten-year flood. (3) The backflow preventer is an RP and is installed in such a manner that the RPs relief valve port could be submerged as a result of discharge through the RPs relief valve. (4) The backflow preventer is a PVB and is installed with its check valve less than twelve (12) inches above any downstream piping or water outlets. (e) In areas served by reclaimed water, the city shall have the authority to inspect private premises for cross connections between the consumer's potable water system and reclaimed water system. Inspection frequency will be based on the consumer's demand for reclaimed services. High demands will require annual inspections of the premises. Low demands will require inspections once every three (3) years.
(Ord. No. 98-23, § 10, 3-18-98; Ord. No. 00-20, § 2, 1-19-00)
Ask a question about Miramar law
Corpus searches the Miramar sections it holds and shows the ones that match, with their citations. Free, no sign-in.