§ 101.4 — ALL NEW WORK TO CONFORM

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, App. A, ch. I, § 101.4

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/33e8088b-b5a7-4346-aa48-6eb7e465f9a7

101.4. - ALL NEW WORK TO CONFORM.

(a) No building or structure shall hereafter be constructed, repaired, altered, or removed, nor shall the equipment for the operation of a building, structure, or premises be constructed, installed, altered, repaired or removed, except in conformity with the provisions of this Code, unless specifically exempted therefrom. (b) No building or structure shall be altered in any manner which would be in violation of the provisions of this Code or of any authorized rule or approval of the Director of the Bureau of Buildings made and issued thereunder, unless specifically exempted herein. (c) Nothing in this Code shall prohibit the raising or lowering of a building to meet a change of grade in the street on which it is located, provided that the building is not otherwise altered. (d) Whenever, in the opinion of the Director the full implementation of this Code would work an undue hardship in a specific case, the Director may waive the requirements in question to provide that some equivalent means of achieving substantially the same degree of safety is assured. Said waiver shall be in writing and shall state the equivalent methods by which safety shall be assured. Said waiver shall be made a part of the plans or permits in question. (e) Mandatory automatic fire suppression systems. Except as provided in Section 101.4(e)(5) or otherwise noted, the following buildings and occupancies hereafter constructed shall be provided throughout with an approved automatic sprinkler system or other approved automatic extinguishing equipment. For the purpose of this section, stories or height shall be counted at the primary level of exit discharge and ending at the highest occupied level. The primary level of exit discharge shall be that floor which is level with or above finish grade for fifty (50) percent or more of the buildings perimeter. Building levels below the primary level shall not be counted as a story in determining the height of a building; provided however that open air parking garages serving the buildings or occupancies referenced in this section are not required to be provided with automatic sprinkler protection. (1) All multi-family dwellings and hotels three (3) stories or more in height; provided however, that a three (3) story building not otherwise required to be provided with automatic sprinkler protection in accordance with Table 400 (Allowable Heights and Building Areas) and designed such that each dwelling unit or guest room is provided with a direct exit to the exterior or is provided with open air balconies that provide exit access to approved exit(s) may be permitted without sprinkler protection. Such automatic sprinkler systems shall be designed in accordance with NFPA 13-1985 (Standard for the Installation of Sprinkler Systems); provided however, that buildings not exceeding six (6) stories in height, may be designed in accordance with NFPA 13-R-1989 (Standard for the Installation of Residential Sprinkler System) or any subsequent rules that the Director may publish to provide economical installations, including but not limited to, hydraulic design method or innovative piping materials. (2) See Section 506, Special Provisions for Highrise Group R and Group B Business Buildings for sprinkler and additional requirements. (3) All buildings five (5) stories or more in height. (4) All other buildings and portions of buildings and occupancy classifications, required elsewhere in this Code and including the Georgia Safety Fire Law, amended. (5) Areas within telecommunications equipment buildings, used exclusively for telecommunications equipment and associated generator and power equipment and under the exclusive control of a telecommunications provider shall be exempt from requirements of mandatory sprinkler protection sections where the following alternate requirements are satisfied: (a) Such areas are separated from the remainder of the building by construction equivalent to a one hour fire resistant wall and two hour floor/ceiling assemblies. (b) Such areas are provided with automatic fire detection to respond to visible and invisible particles of combustion. (6) It shall be mandatory to provide an automatic fire sprinkler system in all new occupancies described in the building code as R-1 and R-2.

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.