§ 101.8 — APPLICATION TO EXISTING BUILDINGS

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, App. A, ch. I, § 101.8

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/8f6247f7-ab30-4d78-a59b-cb83a332f2d3

101.8. - APPLICATION TO EXISTING BUILDINGS.

(a) General. The purpose of this section is to provide a minimum standard for safety to life in existing buildings not conforming to the requirements of this Code for new buildings with respect to means of egress, including enclosures of floor openings; the intent being to provide for continued use of existing buildings without undue hardship where possible, provided however, if the occupancy of an existing building is entirely changed, the building shall be made to conform to the requirements of this Code for the new occupancy. If the occupancy of only a portion of an existing building is changed and that portion is separated from the remainder as stipulated in Section 403, then only such portion need be made to conform. The specific requirements of this Section may be modified by the Director to allow alternative arrangements that will secure as nearly equivalent safety to life from fire as practical, but in no case shall the modification afford less safety to life, in the judgement of the Director, that would be provided with compliance with the corresponding provision contained in this Code or other referenced standards. (b) Retroactive Automatic Sprinkler Protection. The following buildings in existence at the time of this Code shall be provided with automatic sprinkler protection in accordance with NFPA 13, Standards for the installation of Sprinkler System or other standards as indicated or modified in this Section 101.8(b): For the purpose of this section, stories or height shall be counted at the primary level of exit discharge and ending at the highest occupied level. The primary level of exit discharge shall be that floor which is level with or above finish grade for fifty (50) percent or more of the buildings perimeter. Building levels below the primary level shall not be counted as a story in determining the height of a building; provided however that open air parking garages serving the buildings or occupancies referenced in this section are not required to be provided with automatic sprinkler protection. (1) All business occupancy (Group B) buildings six (6) stories or over 75 ft. in height shall be provided throughout with a complete approved automatic sprinkler system or other approved automatic suppression system designed in accordance with NFPA 13 - 1989 within the time period specified herein; provided, however that new full floor tenant alterations exceeding $25,000 in valuation which includes the removal/installation of fixed partitions or ceiling systems (including electrical lighting above the ceiling), shall install automatic sprinkler protection for that space only as a condition of that alteration permit. Exception: Areas within telecommunications equipment buildings, used exclusively for telecommunications equipment and associated generator and power equipment, and under the exclusive control of a telecommunications provider shall be exempt from requirements of this section where the following alternate requirements are satisfied: (a) Such areas are separated from the remainder of the building by construction equivalent to a one hour fire resistant wall and two hour floor/ceiling assemblies. (b) Such areas are provided with automatic fire detection to respond to visible and invisible particles of combustion. (2) All mercantile and institutional occupancies six (6) stories or over 75 ft. in height. (3) All residential occupancies (Group R) six (6) stories or more in height shall be designed in accordance with NFPA 13 or any subsequent rules that the Director of the Bureau of Buildings may publish to provide economical installations, including, but not limited to, hydraulic design methods, or innovative piping materials. (4) Any assembly occupancy used or capable of being used for exhibition or display purposes shall be protected throughout by an approved automatic sprinkler system when the exhibition or display area exceeds 15,000 sq. ft. (5) The following requirements shall be the specific responsibility of the authorized sprinkler contractor and shall be applicable where existing Class I, Class II or Class III standpipes are utilized to provide a Combined Standpipe system: i. During such time periods as the installation of sprinkler systems may require, no standpipe or fire pump may be made inoperative without the Fire Department being given twenty-four (24) hour prior notice. Such notice shall be made by notifying the City of Atlanta Fire Communication Center at telephone number 911; and, ii. Where buildings contain two (2) or more standpipes, at least one standpipe shall be maintained in such a manner that water can be discharged through piping, valves, hose outlets and allied equipment for the purposes of extinguishing a fire. Where a building contains only one (1) standpipe riser, modifications to the system shall be conducted after normal working hours; and, iii. Appropriate temporary signage shall be provided at all Fire Department Connections on the building indicating the operational status of the system. (6) All total systems required in Section 101.8(b) shall be installed by December 31, 1995. No business license or permission to occupy shall be issued to such buildings unless when in compliance with this Code. Exceptions: (a) For buildings and individual spaces within buildings having documented leases that presently extend beyond December 31, 1995, an extension to December 31, 1999 shall be allowed provided however that leases of such building and spaces which expire between December 31, 1995 and December 31, 1999 shall be subject to compliance within 12 months of lease expiration. (b) For buildings and individual tenant spaces within buildings presenting documented evidence of major asbestos presence or other toxic materials which would directly affect the installation of automatic sprinkler protection an extension to December 31, 1999 shall be allowed; provided, however that new full floor tenant alterations exceeding $25,000 in valuation which includes the removal/installation of fixed permanent partitions or ceiling systems (including electrical lighting above the ceiling), shall install automatic sprinkler protection for that space only as a condition of that alteration permit. (c) For buildings exceeding one million square feet in size an extension to December 31, 1999, shall be allowed; provided however, that new tenant alterations exceeding $25,000 in valuation which includes the removal/installation of fixed permanent partitions or ceiling systems (including electrical lighting above the ceiling) and which includes a minimum of one half (½) of the total area as measured contiguously on the affected floor, shall install automatic sprinkler protection for that space only as a condition of that alteration permit. (d) Condominiums (as defined in the Georgia Condominium Act at O.C.G.A. § 44-3-71(7). (c) Requirements for Retroactive Mechanical and Electrical Systems. (1) Where new full floor tenant alterations exceeding $25,000 in valuation which includes the removal/installation of fixed permanent partitions or ceiling systems (including electrical lighting above the ceiling) are performed, all abandoned wiring previously utilized for low voltage systems which are not approved for return air plenums shall be removed from above the ceiling plenum spaces, or the plenum space shall be protected with automatic partial sprinkler protection. (2) All HVAC units exceeding 5,000 cfm shall be provided with listed smoke detectors installed in the supply system downstream of the filters to detect the presence of smoke and automatically stop the fan(s). Such modification shall be installed by December 31, 1995. (3) For existing buildings having electrical systems of 277/480 volts with 1,000 amps or more which are designed without ground fault protection and use electric bussways, heat detectors shall be installed in each electrical room to disconnect the overcurrent device supplying that circuit. Such modification shall be installed by December 31, 1995. Exception: Telecommunications equipment buildings, used exclusively for telecommunications equipment and associated generator and power equipment and under the exclusive control of a telecommunications provider shall be exempt from requirements of this section. (d) If, within any twelve (12) month period, alterations or repairs costing in excess of fifty (50) percent of the physical value of the building at the time of renovation are made to an existing building, such building shall be made to conform to the requirements of this Code for new buildings. (e) If an existing building is damaged by fire or otherwise in excess of fifty (50) percent of the physical value before such damage is repaired, it shall be made to conform to the requirements of this Code for new buildings. (f) If the cost of such alterations or repairs within any twelve (12) month period or the amount of such damage as referred to in Section 101(d) is more than twenty-five (25) percent but not more than fifty (50) percent of the physical value of the building at the time the damage occurred, the portions to be altered or repaired shall be made to conform to the requirements of this Code for new buildings to such extent as the Director of the Bureau of Buildings may determine in accordance with the requirements for Existing Occupancies in the Code for Safety to Life from Fire in Buildings and Structures (NFPA 101-1985). (g) For the purpose of this section, physical value of the building shall be determined by the Director of the Bureau of Buildings. (h) Repairs and alterations, not covered by the preceding paragraphs of this section, restoring a building to its condition previous to damage to deterioration, or altering it in conformity with the provisions of this Code or in such manner as will not extend or increase non-conformity or hazard, may be made with the same kind of materials as those of which the building is constructed; but not more than twenty-five (25) percent of the roof covering of a building shall be replaced in any period of twelve (12) months unless the entire roof covering is made to conform with the requirements of this Code for new buildings.

(Ord. No. 1983-13, § 1, 3-11-83; Ord. No. 1983-14, § 1, 3-11-83; Ord. No. 1989-89, §§ I—IV, 12-22-89; Ord. No. 1993-20, § 1, 6-7-93; Ord. No. 2008-06(06-O-0262, § 1, 2-12-08)

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.