§ 108 — LIABILITY
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, App. D, ch. I, § 108
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/16faf706-c128-44e2-9236-02da4748ada5
108— - LIABILITY
This Code shall not be construed as imposing upon the City of Atlanta any liability or responsibility for damages to any person or property caused by any defect in any piping or appliance mentioned herein, or by installation thereof, nor shall the City of Atlanta or any official or employee thereof, be held as assuming any such liability or responsibility by reason of the inspection authorized hereunder or the certificate of approval issued by the Inspector. SECTION 2: That Section 201, General Definitions, be altered by adding the following definitions in their proper places, and that the definitions on "Combustible Material" be replaced as follows: Combustible Material. As pertaining to materials adjacent to or in contact with heat producing appliances, vent connectors, gas vents, chimneys, steam and hot water pipes, and warm air ducts, shall mean materials made of or surfaced with wood, compressed paper, plant fibers, or other materials that are capable of being ignited and burned. Such material shall be considered combustible even though flame-proofed, fire-retardant treated, or plastered. For the purposes of NFPA 96 - GYPSUM WALLBOARD is considered a combustible material. Director: The Director of the Bureau of Buildings is the administrative authority to administer and enforce the provisions of this Code as adopted or amended. Person. This shall include an individual, partnership, joint venture, association, corporation and any other legal entity recognized by the laws of the State of Georgia. Smoke Damper - See NFPA 90A. SECTION 3: That Chapter 3, Air Conditioning, Heating and Ventilation Equipment, be amended as follows: (a) In Section 301.2, Add the following Exception: EXCEPTION: The following procedure is hereby established for acceptance of unlisted heating equipment for industrial applications where such listing by an approved agency is not practical due to equipment size or configuration. The following information shall be submitted to, and accepted by, the Director prior to the ordering and installation of equipment: 1. A statement that the application of the heating equipment is for industrial use. 2. A notarized Letter of Acceptance from the insurance carrier that the insurance carrier has reviewed the plans and specifications for the unlisted heating equipment and found them to be satisfactory. Where the owner is self-insured, the owner shall submit the same statement. 3. Shop drawing and/or plans for the installation must be sealed by a licensed professional mechanical engineer registered in the State of Georgia. 4. A notarized letter from a professional mechanical engineer registered in the State of Georgia stating that the engineer shall personally supervise the installation and start-up procedure of the unlisted equipment, and all findings and recommendations shall be forwarded to the Director. 5. A statement that the installation shall be reviewed and approved by the Atlanta Gas Light Company where natural gas is utilized as a fuel source. Where other fuel sources are used, similar such approvals shall be required by the appropriate vendor. 6. A statement by the property owner that the insurance carrier will be specifically requested to witness the start-up procedure, where applicable. 7. A statement that a permit shall be obtained from the City of Atlanta HVAC Division before installation is started. Upon satisfactory resolution of the above requirements, a permit may be issued for such installation. All inspections thereafter shall be conducted as usual except that the inspector shall be present to witness the above-mentioned start-up procedure. (b) That Section 302.4 be modified by adding the following standards: Title of Standard | Designation Vapor Removal from Cooking Equipment | NFPA 96, 1984 National Fuel Gas Code | NFPA 54, 1988 Life Safety Code | NFPA 101, 1985 (c) Add new Section: 303.1.2 TEMPERATURE CONTROLS (See Chapter 5 of the Georgia State Energy Code). (d) That Section 303.5 (2) be amended to read as follows: "All mechanical equipment supported from the ground shall rest on a concrete slab not less than 3 inches above adjoining ground level, concrete cap block - 4 inches thick, or 8 × 8 × 16 inch concrete blocks may be used." (e) That Section 303.11 entitled Electric Heating Equipment, shall be modified by adding following Section 303.11.4: "303.11.4 Duct heaters shall be installed with proper clearances from air handlers, outlets, transitions, elbows, etc. as per listing or as per SMACNA Ducted Electric Heat Guide, 1971." (f) That Section 303 be modified by adding the following Section 303.13: 303.13 FUEL FIRED APPLIANCES IN RESIDENTIAL GARAGES "303.13.1 Fuel fired appliances in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18 inches above the floor. Such equipment shall be located, or protected, so it is not subject to physical damage by a moving vehicle." (g) That Section 304.1 entitled Boilers shall be deleted in its entirety and the following be substituted in lieu thereof: 304.1 General. "Certification requirements, repairs, installations, and alterations shall be in accordance with the Official Code of Georgia Annotated Title 34 Chapter 11 (Boiler and Pressure Vessel Safety Act). All boilers must be permitted and inspected by the State of Georgia, Department of Labor, Safety Engineering Section." (h) That Section 307.1, entitled Required Systems and Ventilation Rates be modified by adding the following sentences: "See City of Atlanta Building Code for ventilation of enclosed and basement parking decks and for pressurization of stairways and elevator shafts. See Georgia State Energy Code for Buildings for mechanical ventilation criteria." (i) That Section 308.4, entitled Grease Hood Duct Systems, 308.5 Exhaust Outlets, 308.6 Hoods, 308.7 Fire Extinguishing Equipment, be deleted in their entirety and substitute the following in lieu thereof:
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.