Section 7.12.6. - Standards to be Used in Designing System.

A. Storm Detention Facilities. All development plans will require a hydrology study stamped and signed by a registered engineer or landscape architect. If detention has been waived or provided in a previous section, then a letter with supporting documents should be provided. Permanent detention facilities will be required, and shall be designed so that the following standards shall apply: 1. Excess Runoff. The excess runoff created by new development shall be compensated for in accordance with the provisions of the Georgia Stormwater Management Manual. 2. Water Quality Treatment. Water quality treatment shall be in accordance with the provisions of the Georgia Stormwater Management Manual. 3. Detention Requirements. Detention shall be provided such that the peak rate of flow from the site after development will not exceed the corresponding flow that would have been created by the 2-year, 10-year, 25-year and 100-year return frequency storms prior to development. 4. Detention Pond Size Determination. The size, capacity and operational characteristics of a stormwater detention facility shall be in accordance with the provisions of the Georgia Stormwater Management Manual. 5. Emergency Overflow Devices. An emergency overflow device, excluding the throttling device, for a detention pond shall be designed to pass the 100-year peak inflow without overtopping the dam. 6. Minimum Berm Width. The top of the berm shall be a minimum of 15 feet wide when 3:1 slopes are used and 10 feet wide with 5:1 slopes. 7. Stability. Slopes shall be stable under all conditions including maintenance, and a minimum 3:1 on City accepted ponds. 8. Vegetative Coverage. Full and living coverage of an approved permanent grass devoid of noxious weeds shall be provided. 9. Pond Bottom. The bottom of the pond shall be firm enough to be maintained by mechanical means per City standards. 10. Access. A ten foot wide access road shall be required around the circumference of the pond, where topography does not prohibit this. The access road shall be located within a 20-foot wide access easement that is deeded to the City, fully accessible to maintenance vehicles, and void of any conflicts with utilities, fences, landscaping and similar items. 11. Fencing. Where fences are provided they shall be a minimum 3.5 and 6 feet high. (A) Chain Link Fencing. Commercial gage chain link fence shall be screened. (B) Wood Fencing. If it a wood fence is desired it shall be placed on the lots of the individual property owners. These fences shall be the maintenance responsibility of individual owners and this responsibility shall be shown on the plats and deeds at dedication. 12. Hydrological Study. As part of the hydrological study, consideration shall be given to the flow capacity of downstream drainage structures. If the downstream system is inadequate, the developer is required to either improve the down stream drainage structure or provide additional storage in the detention facility. 13. Damming. In approved cases the detention may be provided by damming a natural basin with minimal clearing. The required discharge structure opening must be large enough to prevent stoppage from leaves and other debris naturally occurring. Also, the volume should be adequate to account for natural growth of vegetation. B. Storm Drains. 1. Sizing and Location of Drainage Structures. Sizing and location of all existing and proposed drainage structures shall be the responsibility of a registered professional engineer or landscape architect, subject to approval by the City Engineer. 2. Sloping of Pipes. Storm drainage pipes shall be sloped so as to maintain a minimum velocity of 3 feet per second (fps) so that sediment will not collect. 3. Standards for Materials and Installation. Georgia DOT Standard 1030D, or most current standard, shall be used in determining class (concrete) or gauge of pipe under fill, method of backfilling and pipe installation. 4. Drainage Formula. The drainage formula used in determining size of drainage structure shall be determined by the developer's engineer or landscape architect according to accepted engineering practice, subject to approval of the City Engineer. 5. Certification. A registered engineer or landscape architect shall certify the storm drain pipe sizes. 6. Design Storm Event. The 25-year storm event shall be used in designing the storm drains, inlets, cross-drains, etc. that comprise the drainage system. In cases where a spring, creek, or other watercourse traverses the property, the 100-year storm event will be used for design. Lane spread shall be no more than ½ the travel lane width. C. Subdrainage. Subdrainage will be installed to control the surplus ground water by intercepting sidehill seepage or by lowering or regulating the ground water level where such conditions exist. D. Bridge Design. Bridges shall be designed for a 100-year storm event.

Ask a question about Columbus law

Corpus searches the Columbus sections it holds and shows the ones that match, with their citations. Free, no sign-in.