CB101 — GENERAL
Revised Ordinances of Honolulu (2026 S-11: Supplement 11, Ordinance No. 26-1 through Ordinance No. 26-18, June 30, 2026) · Revised Ordinances of Honolulu ch. 16B, § CB101
Corpus is an independent public-information project, not the official City of City and County of Honolulu website. Stable reference: corpuslaw.us/code/691b8064-68e6-4dbf-adb1-a31e7bef9b42
SECTION CB101 GENERAL
CB101.1 Purpose. The purpose of this appendix is to support the City and County of Honolulu’s energy and climate goals by accelerating the savings obtained from the commercial building sector through their local building energy codes. The City and County of Honolulu recognizes the need for Hawai‘i to dramatically reduce greenhouse gas (GHG) emissions to avoid the most catastrophic effects of climate change. This voluntary Stretch Code is supportive of the State’s goal of achieving net negative GHG emissions no later than 2045 and advancing implementation of the O‘ahu Resilience Strategy. In addition, the Stretch Code helps deliver significant co-benefits to the community of Honolulu, which will enhance the quality of life within the community. The Stretch Code was developed to focus on the interaction of commercial buildings with the energy grid, supporting both grid and building decarbonization. CB101.2 Scope. This code applies to commercial buildings, as defined by the International Energy Conservation Code and ASHRAE Standard 90.1, that opt to follow the voluntary Stretch Code. CB101.3 Requirements. Commercial buildings shall comply with the requirements of sections indicated within Table CB 101.3 and Sections CB 103 through CB105. Table CB101.3REQUIREMENTS FOR STRETCH CODE IECC SECTION | TITLE Table CB101.3REQUIREMENTS FOR STRETCH CODE IECC SECTION | TITLE Envelope C402.5 | Air leakage-thermal envelope Mechanical C403.1.1 | Calculation of heating and cooling loads C403.1.2 | Data centers C403.2 | System design C403.3 | Heating and cooling equipment efficiencies C403.4, except C403.4.3, C403.4.4 and C403.4.5 | Heating and cooling system controls C403.5.5 | Economizer fault detection and diagnostics C403.7, except C403.7.4.1 | Ventilation and exhaust systems C403.8, except C403.8.6 | Fan and fan controls C403.9 | Large-diameter ceiling fans C403.11, except C403.11.3 | Refrigeration equipment performance C403.12 | Construction of HVAC system elements C403.13 | Mechanical systems located outside of the building thermal envelope Service Water Heating C404 | Service water heating Electrical Power and Lighting C405, except C405.3 | Electrical power and lighting systems Maintenance and Commissioning C408.1.1 | Building operations and maintenance information
Ask a question about City and County of Honolulu law
Corpus searches the City and County of Honolulu sections it holds and shows the ones that match, with their citations. Free, no sign-in.
