§ 11-119 — Fire safety
Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 11-119
Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/5b0853c9-d77d-41c7-93a2-80995da82c5a
Sec. 11-119. - Fire safety.
(a) Performance requirements. All rental housing shall be provided with fire protection equipment as follows: (1) All dwelling units shall be provided with a sufficient number of fire extinguishers which are approved by the fire marshal. Fire extinguishers shall be properly mounted and accessible to all occupants. Fire extinguishers shall comply with National Fire Protection Association, Standard 10. Minimum size shall be 2A:10B:C. Fire extinguishers shall be equipped with a sight gauge to indicate pressure and shall be maintained in accordance with National Fire Protection Association, Standard 10. (2) All dwelling units shall be provided with smoke detectors as defined in International Fire Code, 2015 Edition section 907.2.11. In multiple unit dwellings, there shall be smoke detectors in common hallways accessible to two or more units. Detectors shall also be located in cellars or basements when such cellars or basements are used for storage, laundry equipment or central heating units. a. Effective January 1, 2014, all dwelling units shall be equipped with dual sensor smoke detectors as defined in Iowa Code § 100.18 and 661 Iowa Admin. Code 210.1. b. Effective January 1, 2015, all dwelling units that have attached garages or within which fuel-fired appliances exist, shall have an approved carbon monoxide alarm installed outside of each separate sleeping area in the immediate vicinity of the bedrooms. Single station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed in accordance with this code and the manufacturer's installation instructions. Dual sensor smoke detectors that have carbon monoxide and smoke detection sensors which are listed to UL 2034 and UL 217, shall be allowed. c. Effective January 1, 2018, all newly registered rental dwelling units and those changing ownership that do not contain hardwired provision for electric detection shall be provided with ten-year battery tamper proof dual sensor smoke detectors or ten-year battery tamper proof combination dual sensor smoke detectors/carbon monoxide detectors that comply with this section. d. Effective January 1, 2018, each time a smoke detector in a rental dwelling unit that is hardwired for electric detection is replaced, repaired, or removed, or is ordered to be replaced, repaired or removed, it shall be replaced with a dual sensor smoke detector that is hardwired for electric detection that complies with this section. Each time a smoke detector in a rental dwelling unit that is not hardwired for electric smoke detection is replaced, repaired, or removed, or is ordered to be replaced, repaired, or removed, it shall be replaced with ten-year battery tamper proof dual sensor smoke detectors that comply with this section. 1. Effective January 1, 2021, all rental units that do not contain hardwired provision for electric smoke detection shall be provided with ten-year battery tamper proof dual sensor smoke detectors that comply with this section. 2. In accordance with 661 Iowa Admin. Code 210.3(11), smoke detectors shall be located as follows: (i) On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of the bedrooms. (ii) In each room used for sleeping. (iii) In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwelling unit with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one story below the upper level. A. All new smoke detectors are required to be a "dual sensor smoke detector" as defined in 661 Iowa Admin. Code 210.1; B. The term "dual sensor smoke detector" means a smoke detector which contains both an ionization sensor and a photoelectric sensor and which is designed to detect and trigger an alarm in response to smoke detected through either sensing device, or a smoke detector which has at least two sensors and is listed to Underwriters Laboratory Standard 217, Single and Multiple Station Smoke Alarms, or to another standard approved by the state fire marshal. 3. Carbon monoxide alarms. Effective May 1, 2011, all new registered dwelling units that have attached garages or within which fuel-fired appliances exist, shall have an approved carbon monoxide alarm installed outside of each separate sleeping area in the immediate vicinity of the bedrooms. Single station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed in accordance with this Code and the manufacturer's installation instructions. (3) Every floor above the first story used for human occupancy shall meet the exit requirements of section 11-120. If the structure cannot meet such exit requirements because it has only one approved means of egress, fire escape stairs will be permitted to serve as part of the second approved means of egress, provided such second means of egress meets all of the following performance standards in addition to all other requirements for a means of egress: a. Fire escape stairs must serve an occupant load of ten or less or a single dwelling unit or guestroom; and b. There must be access to the fire escape stairs from each dwelling unit on each story served by the fire escape stairs, by means of either an approved exit or an approved balcony. Nothing contained in this section shall be construed to vary the provisions of section 11-120(b)(1) requiring emergency escape or rescue windows in every sleeping room, or the provisions of section 11-117(a) through (c) regarding access to dwelling units and between the various rooms of dwelling units. (b) Structural requirements. (1) Fire escape stairs must not pass in front of any building opening below the unit being served. (2) The means of activating the escape device must be accessible to the rental unit or balcony being served. (3) Installation of fire escape stairs must not cause a person to pass within six feet of external electrical wiring. (4) Fire escape stairways and balconies must support the dead load plus a live load of not less than 100 pounds per square foot. Stairway pitch shall be more than 60 degrees, with a minimum width of 18 inches. Stair treads shall not be less than four inches, and the rise between treads shall not exceed ten inches. All horizontal and balcony rails shall support a horizontal force or not less than 50 pounds per linear foot of railing. (5) Fire escape stairs must reach the ground or be equipped with counterbalanced extensions which will allow them to extend to the ground. (c) Acceptability criteria. Acceptability criteria are the same as performance and structural requirements. In addition, fire escapes must be kept clear and unobstructed and must be in good operating order.
(Code 2017, § 14-96; Ord. No. 2178, § 1, 2-24-1997; Ord. No. 2270, § 5, 7-12-1999; Ord. No. 2643, § 10, 1-14-2008; Ord. No. 2744, §§ 7, 8, 4-25-2011)
Ask a question about Cedar Falls law
Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.