For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11-120 — Exits

Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 11-120

Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/28c1a872-0fc3-44b5-aa3b-8df8174a959b

Sec. 11-120. - Exits.

(a) Performance requirements. Every rental dwelling and rooming unit shall have access to two independent, unobstructed means of egress remote from each other. Except for a dwelling or rooming unit on the first story or below grade, neither means of egress shall consist solely of a window approved for emergency escape or rescue. At least one mode shall be an exit which discharges directly to a corridor, stairway or public way. If both exits are to a common corridor, they shall permit emergency egress in two directions. (b) Structural requirements. (1) Sleeping rooms shall have at least one operable window or exterior door approved for emergency escape or rescue. The units shall be operable from the inside without resorting to separate tools. Doorways shall be at least six feet, four inches high by at least 36 inches wide. Escape or rescue windows shall have a minimum net opening of 5.7 square feet. The minimum net opening height shall be 24 inches, with a minimum net opening width of 20 inches and a maximum sill height of 44 inches from the floor. (2) Stairways having more than four risers shall be equipped with a substantial and safely constructed handrail of a height not less than 34 inches and not more than 38 inches above front nosing of stair tread. The stairway rise height shall be uniform, and each tread shall be of uniform width to allow uniform stepping motion for traversing the stairway. (3) Porches, balconies or raised floor surfaces located more than 30 inches above the floor or grade below shall have guards not less than 36 inches in height. Open sides of stairs with a total rise of more than 30 inches above the floor or grade below shall have guards not less than 34 inches in height measured vertically from the nosing of the stair treads. (c) Acceptability criteria. Acceptability criteria are the same as performance and structural requirements.

(Code 2017, § 14-97; Ord. No. 2178, § 1, 2-24-1997; Ord. No. 2270, § 6, 7-12-1999; Ord. No. 2643, § 11, 1-14-2008)

Ask a question about Cedar Falls law

Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.